I/O Modules
The following I/O modules are available to create a custom control solution.
16 Channel Universal IO Module Galavanically isolated Input/Output to chassis (p.27)
8-point universal analog input modules: Galvanic isolation point to chassis inputs may be mixed on a module and may include multiple thermocouple types,
RTDs, ohms, voltage or mill voltage types – all easily assigned using the Process Control Designer configuration tool.
High point-to-point galvanic isolation simplifies installation and saves the expense of external isolation hardware (p.6).
16-point high level analog input module: each point is configurable for V or mA. Galvanically isolated point to
chassis. Galvanically isolated point to point (p.10). 250-ohm shunt resistors can be added per channel.
4-point galvanically isolated analog output module.
Galvanically isolated point to chassis supports from 0 to 20mA each (p.12).
8-point analog output, galvanically isolated in 2 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.13).
16-point analog output, galvanically isolated in 4 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.14).
16-point digital input modules: Contact closure type, DC Voltage, AC Voltage and AC/DC voltage types (p.15).
Galvanically isolated in groups of 8 channel to chassis
32-point digital input module: DC voltage. Galvanically isolated point to chassis. Galvanically isolated in 2
groups of 16 points (p.1915).
8-point AC or 16-point DC digital output modules (sinking type). Galvanically isolated point to chassis.
Galvanically isolated in 2 groups of 8 points (p.18).
32-point digital output: DC voltage (sourcing type).
Galvanically isolated point to chassis. Galvanically isolated in 2 groups of 16 points (p.23).
8-point relay output module: four form C type and four form A type relays.
Galvanically isolated point to chassis. Galvanically isolated relay to relay (p.20).
4 channel Pulse/Frequency/Quadrature I/O module.
Galvanically isolated point to chassis (p.24).
Overview
Reduced configuration time; reduced equipment monitoring and diagnostic time when paired with Experion SCADA
Uses and Examples
• Geographically distributed asset control
• O&G pipelines, storage, and terminals
• O&G well-pad control
• Liquid and gas flow computing
• Block valve stations
• Flow metering
• Water distribution
• Mining
• Renewable energy
Capabilities
• IEC 61131-3 Control Programming (Ladder, ST, IL, SFC, FBD)
• Low power consumption
• -40C to 75C Extended Temperature Operation
• ISA100 Wireless I/O
• HART I/O for Diagnostics and Asset Management
• DNP3 with History Recovery to SCADA
• Flow Computer Option
• ISASecure Level 2 Certification for redundant and non-redundant controllers
ControlEdge™ is a next generation family of controllers providing secure connectivity
through all levels of process and business functions, optimized operations,
and maintenance efficiencies to meet your diverse automation needs.
These controllers additionally support inherent integration with Experion® systems when needed to deliver a fully cohesive automation solution.
The ControlEdge family of controllers turns data into actionable insight, from edge to enterprise, to help customers improve their bottom line.
Insert and Removal of I/O under Power
For ease of maintenance, the ControlEdge HC900 controller
supports removing and inserting I/O modules from the
module rack without removing power from the controller.
Each module is sensed for validity by the controller
and auto-configured on insertion.
Other Modules
In addition to I/O, the following modules are available.
Scanner 1 module, single port (p.31)
Scanner 2 Module, dual port (p.32)
Universal AC Power Supply, 60W (p.4)
Power Supply 24VDC, 60W (p.4)
Redundant Switch Module (p.33)
Power Status Module (p.33)
Failsafe
All ControlEdge 900 Platform I/O modules support a user
specified failsafe value (analog) or state (digital) that the
module outputs or inputs will assume if communication
between the controller and the module is interrupted. Output
modules are also disabled if the controller fails to start.
Module diagnostics are not initiated if the control strategy
does not call for the inputs or outputs on the modules to
execute.
Failsafe is restricted to de-energize in safety applications.
Other advantageous products on sale are listed below:
EMERSON SE4017P1 S-series H1 I/O Card with Integrated power and Terminal Block
EMERSON SE4037P1 Redundant S-series H1 I/O Card with Integrated power and Terminal Block
EMERSON S-series Virtual I/O Module 2
EMERSON S-series Virtual I/O Module 2 SE4026
EMERSON SE4027 Redundant S-series Virtual I/O Module 2
EMERSON S-series Profibus DP Interface Card
EMERSON SE4022 S-series Profibus DP Interface Card
EMERSON SE4038 S-series Redundant Profibus DP I/O Interface
EMERSON Single Carrier Extender Cable 0.8m (31in) KJ4003X1-BH3
EMERSON Single Carrier Extender Cable 1.1m (43in) KJ4003X1-BH1
EMERSON Single Carrier Extender Cable 1.5m (58in) KJ4003X1-BH4
EMERSON Single Carrier Extender Cable 1.9m (77in) KJ4003X1-BH5
EMERSON Power Terminal Plug for 2-Wide and 8-Wide Carriers KJ4005X1-BF1
EMERSON SE4006P2 S-series Serial Interface Card, 2-ports
EMERSON SE4036P2 Redundant S-series Serial Interface Card, 2-ports
EMERSON S-series Sequence of Events Card
EMERSON SOE interface with 32-screw termination block SE4001S5T2B4
EMERSON SOE interface with Mass term block Connector SE4001S5T2B5
EMERSON S-series Horizontal Carriers
EMERSON Carrier Blank Cap (for 8-Wide I/O Interface Carrier only) SE6101
EMERSON Carrier Blank Cap (for 2-Wide Power and Controller Carrier only) SE6102
EMERSON Left Extender 1-Wide KJ4005X1-BB1
EMERSON Right Extender 1-Wide KJ4005X1-BC1
EMERSON Single Carrier Extender Cable 0.4m (17in) KJ4003X1-BH2