Model 9764-310 RTD/TC/AI Termination Panel
The Model 9764-310 RTD/TC/AI Termination Panel with industry-standard
signal-conditioning modules may be cabled to the Model 2352 Analog Input
External Termination Panel Baseplate. The RTD/TC/AI Termination Panel
supports 16 points and each Analog Input Module can support up to two External
Termination Panel. The input-signal conditioners are manufactured by Analog Devices™.
The Model 9764-310 panel comes with a:
• 10-foot cable
• Mounting plate
The Model 9764-310 panel has a barrier strip with four compression screw
terminals for connecting an AI Module to 16 analog inputs. The panel accepts
power (+24 volts DC) from the AI Baseplate or from direct connection to the panel.
Identifying Fault and Alarm Conditions
You can identify alarm and fault conditions in the following ways:
• By examining the indicators on the front panel of each module and consulting this chapter.
• By using the Diagnostic Panel in the TriStation application.
For more information, see the TriStation 1131 Developer’s Guide.
Fault and Alarm Indicators
Fault indicators identify potentially serious problems with a module. Alarm
conditions identify abnormal field conditions such as loss of power and loss of communication.
If a fault or alarm indicator is on, you should consult the appropriate section of this
chapter and take appropriate action. This action may include replacing a faulty
module or repairing a faulty circuit or device.
Overview
Indicators are lights on the front panel of each module that identify the state of each module.
Each module includes indicators that identify the general state of the module and other indicators related to the function of the module.
The types of indicators include:
• Status indicators which identify the processing state of the module.
Each module includes a Pass, Fault, and Active indicator.
• A lock indicator which identifies whether the module is unlocked.
• Mode indicators which identify the current operating state of the controller.
(Only on MP Modules.)
• Field power and power load indicators which identify whether a power
problem has occurred. (Only on some I⁄O modules.)
• Communication indicators which identify the type of communication occurring.
(Only on MP and CM Modules.)
• Points indicators which identify whether the point is energized.
• Alarm indicators which identify alarm conditions for the controller.
(Only on MP Modules.)
Related Items we have in stock
Triconex | Model 2292 VO Extender Module Kit |
Triconex | 3501E/T 115Vac/VdcDigitalInput |
Triconex | 3502E 48Vac/VdcDigitalInput |
Triconex | 3503E 24Vac/VdcDigitalInput |
Triconex | 3504E 24/48VdcDigitalInput |
Triconex | 3505E 24VdcDigitalInput |
Triconex | 3564 24VdcDigitalInput(simplex) |
Triconex | 3506X 24VdcSupervisedDigitalInput |
Triconex | 3511 PulseInput |
Triconex | 3515 PulseTotalizer |
Triconex | 3601E/T 115Vac Digital Output |
Triconex | 3603B/E/T 120Vdc Digital Output |
Triconex | 3604E 24Vdc Digital Output |
Triconex | 3607E 48Vdc Digital Output |
Triconex | 3611E 115Vac Digital Output |
Triconex | 3617E 48VdcSupervised Digital Output |
Triconex | 3623E/T 120Vdc Digital Output |
Triconex | 3624 24VdcSupervised Digital Output |
Triconex | 3625 24Vdc Digital Output |
Triconex | 3664 24Vdc Digital Output(Dual) |
Triconex | 3626X 24VdcSupervised Digital Output |
Triconex | 3674 24Vdc Digital Output(Dual) |
Triconex | 3636R/T Relay Output |
Triconex | 3701 0-10Vdc Analog Input |
Triconex | 3722X 0-5Vdc Analog Input |
Triconex | 3723X 0-5Vdc Analog Input+Hart |
Triconex | 3703E 0-5,0-10Vdc Analog Input |
Triconex | 3704E 0-5,0-10Vdc(HD) Analog Input |
Triconex | 3706A Thermocouple Analog Input |
Triconex | 3708E Thermocouple Analog Input |
Triconex | 3720 0-5Vdc Analog Input |
Triconex | 3721 0to5or–5to+5Vdc Analog Input |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved