Fault and Alarm Indicators
Fault indicators identify potentially serious problems with a module. Alarm
conditions identify abnormal field conditions such as loss of power and loss of communication.
If a fault or alarm indicator is on, you should consult the appropriate section of this
chapter and take appropriate action. This action may include replacing a faulty
module or repairing a faulty circuit or device.
Identifying Fault and Alarm Conditions
You can identify alarm and fault conditions in the following ways:
• By examining the indicators on the front panel of each module and consulting this chapter.
• By using the Diagnostic Panel in the TriStation application.
For more information, see the TriStation 1131 Developer’s Guide.
KEY CAPABILITIES
• TÜV Certified up to SIL3 applications in accordance with International standard IEC61508
• Easily integrated with all major Distributed Control Systems
• On-line module replacement ensures plant availability by hot-swapping of modules
• Works with both centralized and distributed applications
• Comprehensive family of I/O modules
• HART protocol pass through to Asset Management Systems
• Fast program cycle time for TMC applications
• Expertise available from our TÜV certified Functional Safety Experts and Engineers
• Certified for use in non-incendive applications
EcoStruxure™ Triconex® - Tricon CX
EcoStruxure™ Triconex Safety System – superior protection for people, production and profits
We understand that you need more from your safety instrumented systems than just keeping your operations safe
you need to keep operations running continuously, avoiding any unexpected downtime or interruption that impacts profitability.
EcoStruxure Triconex - Tricon CX is the most powerful safety system from Triconex.
Leveraging the pedigree of the field-proven Tricon, Trident and Tri-GP systems,
Tricon CX is the best possible choice when safety and profitability are critical success factors.
The Tricon system is a must for clients who need to maximize the safety and
performance of their assets. If you are challenged with reducing investment and
lifecycle costs, meeting new safety standards, combating tough competitive
pressure in your markets as well as the welfare of your employees and the
environment, then the Tricon system is designed for you.
A powerful, scalable design with assurance
of continuous operation, the Tricon system complies with international safety
standards such as IEC61508 and fulfils the requirements for applications such as
Emergency Shutdown (ESD), Fire and Gas Protection (F&G), Burner Management
(BMS), High Integrity Pressure Protection (HIPPS) and Turbomachinery Control
(TMC). The redundant high availability architecture provides a flexible, robust,
reliable and powerful solution that is ideal for clients looking to achieve
environmental and safety excellence.
Overview
Indicators are lights on the front panel of each module that identify the state of each module.
Each module includes indicators that identify the general state of the module and other indicators related to the function of the module.
The types of indicators include:
• Status indicators which identify the processing state of the module.
Each module includes a Pass, Fault, and Active indicator.
• A lock indicator which identifies whether the module is unlocked.
• Mode indicators which identify the current operating state of the controller.
(Only on MP Modules.)
• Field power and power load indicators which identify whether a power
problem has occurred. (Only on some I⁄O modules.)
• Communication indicators which identify the type of communication occurring.
(Only on MP and CM Modules.)
• Points indicators which identify whether the point is energized.
• Alarm indicators which identify alarm conditions for the controller.
(Only on MP Modules.)
Tricon Key capabilities
• TÜV-certified for SIL3 applications to international standard IEC61508
• High-availability architecture for continuous operation
• Fault-tolerant architecture for continuous operation even under fault conditions
• Choice of form factors
• Online module replacement ensures continuous operation and plant availability
• Online upgrade without process interruption
• Direct Integration with Foxboro®Evo process automation system
• Easily integrated with all major distributed control systems
• ISA Secure EDSA Level 1 right out of the box
• Works in both centralized and distributed applications
• HART protocol pass through to Asset Management Systems
• Fast program cycle time from 10 mS
• 1 mS SOE Digital Input
• Choice of termination options — Direct and ETP
• Expertise available from our TÜV-certified Functional Safety Experts and Engineers
• Continually current technology
• Comprehensive family of I/O modules
Related Items we have in stock
Triconex Model 3351 Analog Input Module
Triconex Model 2351Analog lnput Baseplate
Triconex Model 2352 Analog input External Termination Panel Baseplate
Triconex Model 9764-310 RTD/TCIAl Termination Panel
Triconex Analog Output Modules
Triconex Model 3481 Analog Output Module
Triconex Model 3482 High-Current Analog Output Module
Triconex Model 2481 Analog Output Baseplate
Triconex Digital lnput Module
Triconex Model 3301 Digital Input Module
Triconex Model 2301 Digital Input Baseplate
Triconex Digital Output Module
Triconex Model 3401 Digital Output Module
Triconex Model 2401 Digital Output Baseplate
Triconex Model 2402 Digital Output Baseplate
Triconex Pulse Input Module
Triconex Model 3381 Pulse Input Module
Triconex Model 3381 Pulse Input Module Specifications
Triconex Model 2381 Pulse Input Baseplate
Triconex Solid-State Relay Output Module
Triconex Model 3451 Solid-State Relay Output Module
Triconex Model 2451 Solid-State Relay Output Baseplate
Triconex LO Extender Modules
Triconex Model 2281 LOExtender Module Kit
Triconex Model 2291 lO Extender Module Kit
Triconex Model 2292 VO Extender Module Kit
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved