Key features
Wide range of protection and control functionality for incoming and outgoing feeders
Extensive earth-fault protection portfolio with unique multifrequency admittance-based protection for higher sensitivity and selectivity
Several optional functionality packages – advanced and fast fault location of short circuits and earth faults,
interconnection protection for distributed power generation, capacitor bank, basic motor and arc protection
Supports native IEC 61850 Editions 1 and 2, including redundancy HSR and PRP,
GOOSE messaging and IEC 61850-9-2 LE for less wiring and supervised communication
Supports Modbus, DNP3 and IEC 60870-5-103 communication protocols and for different time synchronization methods,
including high-accuracy time synchronization via IEEE 1588 V2 Precision Time Protocol

Compact protection and control for a wide variety of feeder applications
REF620 is a dedicated feeder management relay for protection, control, measurement and supervision in
utility and industrial power distribution systems, including radial, looped and meshed networks, with or without distributed power generation.
Compact and versatile feeder protection relay solution with integration of protection, control, monitoring and supervision in one relay.
REF620 is a member of ABB's Relion® family and part of its 620 protection and control product series.
Key benefits
Extensive protection and control functionality, either with sensors or conventional instrument transformers
Functional scalability and extensive possibilities to easily tailor configurations to application-specific requirements
Withdrawable plug-in unit design for swift installation and testing
Large graphical display for showing customizable SLDs, accessible either locally or through an easy-to-use web-browser-based HMI
Extensive life-cycle services
Ethernet redundancy
IEC 61850 specifies a network redundancy scheme that improves the system availability
for substation communication. It is based on two complementary protocols defined in the
IEC 62439-3:2012 standard: parallel redundancy protocol PRP and high-availability
seamless redundancy HSR protocol. Both protocols rely on the duplication of all
transmitted information via two Ethernet ports for one logical network connection.
Therefore, both are able to overcome the failure of a link or switch with a zero-switchover
time, thus fulfilling the stringent real-time requirements for the substation automation
horizontal communication and time synchronization.
AEG Modicon Schneider electric SPS A250 Digital Ausgabe Baugruppe DAP132 DAP 132
MODICON ASE680904 Exec Cartridge AS-E680-904
AEG Modicon CPU A500 ALU286.244603
AEG Modicon A020 Automation Device PLC Controller 7628-042
AEG Modicon KPE 141-1 6355-042.703 946
AEG Modicon PC Board 029.061 510 029.061510 643958
MODICON 984,SCHNEIDER PC-0984-381,AS -9584-000,AS-C 950-103,AEG 984 381,BZ
Modicon Memory Card 8K AS-MEEP-001 EEprom Schneider Gould AEG
AEG DEP-210 8-point 115 VAC Isolated Discrete Input (AS-BDEP-210)
AEG Modicon ALU 286 6051-042.244603 CPU512KEP (244603)
Modicon AEG 410 Servo Positioner 110-280 110280 410-0/890 5/10 A Amps
AEG GM-MBPL-001 Modicon Modbus Plus Network Guide
GOULD AEG MODICON POWER SUPPLY UNIT PS 15B-200 PS15B-200 BEST EBAY 120 D WRNTY
AEG Modicon BIK151 6051-042.239646 Rev17 / Bitbus EA Bitbus 1N / Original Packaging
AEG MPV 003 203608 MODICON EPROM PROGRAMMER