Protection functions
The IED offers directional and non-directional overcurrent and thermal overload protection as
well as directional and non-directional earth-fault protection.
Some standard configurations allow as an option admittance-based, harmonics-based or wattmetric-based earth-fault protection to be
used in addition to directional earth-fault protection.
Further, the IED features sensitive earth-fault protection, phase discontinuity protection, transient/intermittent earth-fault protection,
overvoltage and undervoltage protection, residual overvoltage protection, positive-sequence undervoltage
and negativesequence overvoltage protection.
Frequency protection, including overfrequency, underfrequency and frequency rate-of-change protection,
is offered in IEDs with standard configurations H and J.
The IED also incorporates optional three-pole multi-shot auto-reclose functions for overhead line feeders.
Enhanced with optional hardware and software,the IED also features three light detection channels
for arc fault protection of the circuit breaker, busbar and cable compartment of metalenclosed indoor switchgear.
The arc-fault protection sensor interface is available on the optional communication module.
Fast tripping increases staff safety and security and limits material damage in an arc fault situation.
REF542plus success story
Market launch 2000
Delivered units approx. 50,000
Applications ranging from low voltage to high voltage
In service worldwide
Many different protection and control functions
Event recording
All events are stored with a resolution of 1 ms in the central unit and in the BUs.
System, protection and test events can be generated.
Protection events refer to the protected busbar and include the changes in the disconnector and breaker positions,
trips, etc. Test events are recorded during testing with the test signal generator.
System events describe the diagnostic and fault messages of the NBP system as a whole.
Product features
Motor protection with voltage- and frequency-based protection and measurement functionality
Motor protection both during motor start-up and normal run, with protection and fault clearance in abnormal situations as well
Optional arc protection and high-speed outputs
Supports IEC 61850 Editions 1 and 2, including HSR and PRP, GOOSE messaging and IEC 61850-9-2 LE for less wiring and supervised communication
IEEE 1588 V2 for high-accuracy time synchronization and maximum benefit of substation-level Ethernet communication
Supports Modbus, DNP3 and IEC 60870-5-103 communication protocols
Product benefits
Compact and versatile solution for utility and industrial power distribution systems with integration of protection, control, monitoring and supervision in one relay
Motor protection with motor start-up and loss of load supervision as well as thermal overload,
motor load jam and phase-reversal protection, either with sensors or conventional instrument transformers
Ready-made standard configurations for fast and easy setup with tailoring capabilities
Withdrawable plug-in unit design for swift installation and testing
Large graphical display showing customizable SLDs, accessible either locally or through an easy-to-use web-browser-based HMI
Extensive life-cycle services
REC650 Bay control REC650 ANSI |
RET670 1MRK002816-AG Transformer protection |
REF615 HCFKAEADABC2BAA11E Feeder Protection and Control |
REM615C_E Motor Protection and Control |
REM610C55HCNR Feeder protection measurement and control device |
REM615C55HCNR Motor Protection and Control |
REF615 HBFDACADNAA1BCNIXE Feeder protection and control |
REF615C-E HCFFAEAGABC2BAA11E Feeder Protection and Control |
REF610C55LCNR Feeder protection measurement and control device |
REF620C_F NCFNAAAAABC2DNN1XF Feeder protection and control |
REF615C_D HCFDACADAND2BNN1XD Feeder Protection and Control |
REF615A_1G HAFNAEFCBGC1BQK11G Feeder Protection and Control |
REF615E_1G HBFGDAAHNDCCBNA11G Feeder Protection and Control |
REF615 HCFKAEADABCZDAA11E Feeder Protection and Control |
RET670 1MRK002246-BD Transformer protection RET670 ANSI |
REM545BG229AABA Feeder terminals |
REF543CM129AAAA Feeder terminals |
REG670 Generator protection REG670 Version 2.2 |
REM610 Motor Protection Relay |
REF615E-E Feeder protection and control |
REF545KM133BAAA feeder protects the terminal |
REF615C_C HCFFAEAGANB2BAN1XC REF615 Feeder Protection and Control |
REC670 Bay control REC670 1MRK511313-BEN |
RED670 1MRK004810-KG Line differential protection |
REM615 Motor Protection and Control |
REF615E-1G HBFDACADABC1BNN21G Feeder Protection and Control |
REF611 REF615 REF620 Feeder Protection and Control |
REB670 Busbar protection REB670 Relion 670 series |
REJ603 Self-Powered Feeder Protection |