The Mark * VIeS Functional Safety System reflects GE’ s experience of three-plus decades,
four generations, and over 10,000 installed Triple Modular Redundant(TMR) systems.
The Mark VIeS is certified to IEC 61508 standards to meet the needs of the majority of safety requirements – SIL 2 and SIL 3.
A proven and safe solution
GE brings decades of domain expertise to the Mark VIeS Functional Safety
System. The Mark series of controllers has earned a reputation for superior running
reliability and superior tripping reliability when required in thousands of TMR
systems installed in power generation and infrastructure applications globally. These
proven philosophies are atthe heart of the Mark VIeS Functional Safety System.
Flexibility and reliability Redundancy is a critical feature in safety control system design,
enabling continuous process operation during system maintenance or repair.
The Ethernet backbone of the Mark VIeS Functional Safety System allows each segment of the system to be configured with different levels of redundancy as follows:
• Can be: Simplex, Dual, or TMR
• I/Onetwork (IONet) communications can be: Simplex, Dual, or TMR
• I/O modules can be: Simplex or TMR This flexibility enables customers to design
their system to meet the exact needs of their SIL application requirements, and ultimately reducing system costs.
Customers can customize the level of redundancy to meet safety and running reliability needs.
Simplex Contact Input (STCI) Terminal Board
The STCI terminal board is a compact contactinputterminal board
used for Simplex configurations. The STCI accepts 24 contact
inputs that are supplied with a nominal 24 or 48 V dc excitation
from an external source, or I/O wetting power supply. The contact
inputs have noise suppression to protect against surge and highfrequency noise. The YDIA mounts directly on the STCI terminal
board. The STCI is available in multiple versions to meet customer
requirements. The STCI Terminal Board with YDIA I/OPack
Specifications table provides the specifications for the STCI versions
available for use in the Mark VIeS Functional Safety System.
Contact Input (TBCI) Terminal Board
The TBCI terminal board is a contact input terminal board used
for Simplex, Dual, or TMR configurations. The TBCI accepts 24
dry contact inputs wired to two barrier-type terminal blocks. For
contact excitation, dc I/O wetting power is wired to the TBCI. The
contact inputs have noise suppression to protect against surge
and high-frequency noise. The YDIA I/Opack(s) mount directly on
the TBCI terminal board. The TBCI is available in multiple versions
to meet customer requirements. The TBCI Terminal Board with
YDIA I/OPack Specifications table provides the specifications for
the TBCI versions available for use in the Mark VIeS Functional Safety System.
Hardware Tips and Specifications
This pack has an internally placed BPPx processor board as well as an acquisition board that is used for thermocouple input functions.
Before even considering any ultimate purchase decision on this IS220PTCCH1A device,
it is crucial to understand the fact that this IS220PTCCH1A device is actually not the originally-developed product of its specific Mark V Series intended functional role,
as that would in fact be the IS220PTCCH1 parent Thermocouple Input Module noticeably not adopting this IS220PTCCH1A device's sole A-rated functional product revision.
The IS220PTCCH1A can be used in simplex, duplex, and triple modular redundant applications.
This board can support E, J, K, S, and T standard thermocouples as well as mV inputs with a span of -8 to 45 mV. E, J, K, S, and T thermocouples
can be either grounded or ungrounded and can be located up to 984 feet from the turbine I/O panel. Cable resistance must be kept to a maximum 450 Ω.
The number of packs used dictate the following:
Qty 1 IS220PTCCH1A - 12 Thermocouple Inputs
Qty 2 IS220PTCCH1A - 24 Thermocouple Inputs
Qty 3 IS220PTCCH1A - Used in TMR Configurations
IS220PDIAH1A IS220PDIAH1B Contact Inputs: 24 discrete inputs |
IS220PDIIH1A IS220PDIIH1B Isolated Contact Inputs: 16 discrete inputs |
IS220PDIOH1A IS220PDIOH1B Discrete Inputs/Outputs: 24 Contact Inputs and 12 Form-C Mechanical Relays |
IS220PDOAH1A IS220PDOAH1B Contact outputs: 12 relays with status feedback |
IS220PAICH1A IS220PAICH1B Analog Input/Output: 10 analog inputs and 2 analog outputs |
IS220PAICH2A IS220PAICH2B Analog Input/Output 200 mA output |
IS220PAOCH1A IS220PAOCH1B Analog output: 8, 0-20 mA output |
IS220PPDAH1A IS220PPDAH1B Power Distribution System Feedback |
IS220PTCCH1A IS220PTCCH1B Thermocouple: 12 Combustion Optimization Inputs, 1 Cold Junction |
IS220PTCCH2A IS220PTCCH2B Thermocouple: 12 General Purpose Industrial Inputs, 1 Cold Junction |
IS220PRTDH1A IS220PRTDH1B RTD Input: 8 RTDs |
IS220PSCAH1A IS220PSCAH1B Serial communication: 6 channels |
IS220PCNOH1A IS220PCNOH1B CANopen® Communication |
IS220PPRFH1A IS220PPRFH1B PROFIBUS® Communication |
IS220PHRAH1A IS220PHRAH1B Hart® Analog Input/Output: 10 AI (V/I Input) and 2 AO (0-20 mA Output) |