Power Engineering 
K-JIANG
NameDescriptionContent
  • Basler Electric BE1-67 / BE167 DIRECTIONAL OVERCURRENT RELAY
  • Basler Electric BE1-25/79TR Reclosing Relay BE1 25 79TR
  • Basler Electric Contact Expansion Module CEM-2020
  • Basler Electric MVC-300 MANUAL VOLTAGE CONTROL UNIT 9121000106
  • Basler Electric KR2FF Voltage Regulator 9 1163 00 109
  • Basler Electric CLASS 300 EQUIPMENT MVC-300 ELECTRONIC MANUAL VOLTAGE CONTROL
  • Basler Electric BE1-67 DIRECTIONAL OVERCURRENT RELAY
  • Basler Electric AEM-2020 and CEM-2020 Expansion Modules
  • Basler Electric MVC-300 Electronic Manual Voltage Control
  • Basler Electric BE1-60 Voltage Balance Relay
  • Basler Electric BE1-50BF Breaker Failure Relay
  • Eaton Power Defense molded case circuit breaker
  • Eaton Magnum with Power Xpert Release trip units
  • Eaton Tripp Lite series power conditioners
  • Eaton Tripp Lite series medical-grade isolation transformers
  • Eaton Tripp Lite series isolation transformers
  • Eaton Sag Ride-Through power conditioner
  • Eaton Power-Sure 700
  • Eaton PDI Current Limiting Reactor
  • Beckwith الكهربائية M-6280A الرقمية مكثف التحكم بنك
  • Beckwith الكهربائية M-4272 نظام نقل الحافلات الرقمية
  • بيكويث الكهربائية M-3420 مولد حماية ريلي
  • وحدة Beckwith Electric M-0193B Syncrocloser®
  • بيكويث الكهربائية M-3520 Intertie حماية ريلي
  • إيتون MTL 9470-ET/G جيجابيت نطاق إيثرنت آمن جوهريا
  • ريلاي حماية سلسلة Basler Electric ES
  • باسلر الكهربائية BE1-40Q فقدان الإثارة ريلي
  • لوحة عرض عن بعد لـ Basler Electric RDP-110
  • منظم الجهد الرقمي Basler Electric BE2000E
  • نظام التحكم الرقمي في الإثارة ديكس-150 من باسلر الكهربائي
  • باسلر الكهربائية APR 63-5 تنظيم الجهد
  • باسلر الكهربائية BE1-27. BE1-59. BE1-27/59. ريلي الجهد
  • Eaton MTL RugiCAM-IP high definition intrinsically safe ethernet camera
  • Eaton MTL Intrinsically Safe Power Supplies
  • Eaton MTL ExLAN intrinsically safe ethernet OEM interface
  • Eaton 9661-ETW MTL intrinsically safe ethernet to serial 4 port communication module
  • Eaton MTL SUM5 Smart Universal Marshalling
  • Eaton MTL 9474-ET/ETG and BxLAN-OEM intrinsically safe ethernet barriers
  • Eaton MTL 9460-ET range Intrinsically safe Ethernet products
  • Eaton MTL 9461-ET Intrinsically Safe Serial to Ethernet Gateway
  • Eaton MTL 9466-ET Intrinsically Safe Managed Ethernet Switch
  • Eaton MTL 9468-ET Intrinsically Safe Ethernet Isolator
  • Eaton MTL 9460-ET intrinsically safe ethernet products
  • Eaton MTL 9471-ET(G) Intrinsically Safe Gigabit Ethernet 4 Port Serial Gateway
  • Eaton MTL 9475-ET(G) Intrinsically Safe Gigabit Ethernet Dual Port Media Converter Switch
  • Eaton MTL 9476-ET(G) Intrinsically Safe Gigabit Ethernet 6 Port Managed Switch
  • Eaton MTL 9478-ETG MTL Intrinsically Safe Gigabit* Ethernet Galvanic Isolator
  • Eaton MTL 9479-ET(G)-CSL CSL Intrinsically Safe Gigabit Ethernet WLAN AP / Bridge
  • Beckwith Electric M-0067E Tapchanger Control
  • Beckwith Electric M-2001C Digital Tapchanger Control
  • Beckwith Electric M-2001D Digital Tapchanger Control
  • Beckwith Electric M-2017 Capacitor Bank Discharge Tool
  • Beckwith Electric M-2980A Weatherproof Capacitor Control Cabinet
  • Beckwith Electric M-6283A Three Phase Digital Capacitor Bank Control
  • باسلر الكهربائية DGC-2020HD جهاز تحكم المولدات الرقمية
  • باسلر الكهربائية DGC-2020 جهاز تحكم المولدات الرقمية
  • نظام التحكم الرقمي في الإثارة ديكس-400 من باسلر الكهربائي
  • باسلر الكهربائية BE1-81O / U ريلي التردد الرقمي
  • نظام حماية مولد باسلر الكهربائي BE1-GPS100
  • نظام التحكم الرقمي في الإثارة ديكس 450 من باسلر الكهربائي
  • نظام التحكم الرقمي في الإثارة ديكس-200 من باسلر الكهربائي
  • باسلر الكهربائية DECS-200N نظام التحكم في الإثارة الرقمية القسرية السلبية
  • إيتون F880 طاقة الحافلة الميدانية الزائدة لنظام التحكم Yokogawa CENTUM 3000 R3
  • إيتون F890 إمدادات الطاقة الميدانية الزائدة
  • إيتون T300 المحمولة 31 وظيفة راديو التحكم عن بعد
  • إيتون MTL F880 8 قطاع زائد الميدان الحافلة إمدادات الطاقة
  • إيتون 450U-E مودم إيثرنت لاسلكي وخادم الأجهزة
  • إيتون تريب لايت سلسلة مفاتيح شبكة إيثرنت الصناعية
  • إمدادات الطاقة FISCO الزائدة Eaton MTL
  • محطات الحافلات الميدانية Eaton MTL
  • مركز الطاقة الحافلة الميدانية Eaton MTL
  • محول إيتون MTL Ex IC للعمل الحي
  • إيتون FCS-9000 مجموعة صناديق التقاطع
  • صناديق تقاطع عملية إيتون MTL
  • إيتون MTL4854 متعدد المودم هارت متعدد
  • Eaton JOCKEY Touch™ وحدة تحكم مضخة جوكي القائمة على المعالجة الدقيقة
  • إيتون MTL4850 و MTL4854 هارت® متعددات
  • إيتون MTL4850-TR تريكونيكس 4850 هارت® متعدد
  • إيتون 245U-E نطاق إيثرنت اللاسلكي
  • حماية محرك إيتون MP-4000
  • أنظمة اتصال Eaton MTL4851 و MTL4852 HART®
  • Beckwith Electric M-6280A Digital Capacitor Bank Control
  • Beckwith Electric M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3420 Generator Protection Relay
  • Beckwith Electric M‑0193B Syncrocloser® Unit
  • Beckwith Electric M‑3520 Intertie Protection Relay
  • Eaton MTL 9470-ET/G Gigabit intrinsically safe ethernet range
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler Electric RDP-110 Remote Display Panel
  • Basler Electric BE2000E Digital Voltage Regulator
  • Basler Electric DECS-150 Digital Excitation Control System
  • Basler Electric APR 63-5 Voltage Regulator
  • Basler Electric BE1-27. BE1-59. BE1-27/59. Voltage Relay
  • Basler Electric DGC-2020HD Digital Genset Controller
  • Basler Electric DGC-2020HD Digital Genset Controller
  • Basler Electric DGC-2020 Digital Genset Controller
  • Basler Electric DECS-400 Digital Excitation Control System
  • Basler Electric BE1-81O/U Digital Frequency Relay
  • Basler Electric BE1-GPS100 GENERATOR PROTECTION SYSTEM
  • Basler Electric DECS-450 Digital Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-200N Negative Forcing Digital Excitation Control System
  • Eaton F880 redundant fieldbus power for Yokogawa CENTUM 3000 R3 Control System
  • Eaton MTL F880 8 Segment Redundant Fieldbus Power Supply
Current Location:

E-mail

Password

Register Forgot password?
GE IS220PGENH1A IO PACK, GENERATOR PLU
❤ Add to collection

GE IS220PGENH1A IO PACK, GENERATOR PLU

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
IS220PGENH1A
U.S.$10055.00
U.S.$4548.00
Weight:0.000KG
Quantity:
(Inventory: 4)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
IS220PGENH1A

Part Number IS220PGENH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockThe IS220PGENH1A is a Turbine Generator Monitor Module designed for the Mark VIe system. The electrical interface between one I/O Ethernet network and the TGNA turbine generator is provided by the Mark VIe Turbine-Generator Monitor (PGEN). The pack includes a processor board that is shared by all Mark VIe distributed I/O packs as well as an acquisition board. The pack monitors turbine mechanical power using three analog channels and voltage or 4-20 mA sensors. Functional Description A current transformer input is used to monitor each phase of the generator armature current. The PGEN performs the power load unbalances (PLU) function that the Mark VI VGEN did. It lacks the power calculations (kW, kVARS, KVA) and early valve actuation logic found in the VGEN. Dual RJ45 Ethernet connectors and a 3-pin power input provide power to the pack. For simplex or TMR applications, the PGEN supports single Ethernet networks.

Output is via a DC-37 pin connector that is directly connected to the associated terminal board connector. LED indicator lights provide visual diagnostics. Compatibility PGENH1A functions with the turbine-generator Terminal Board (TGNA). The number of I/O packs used in a signal path is referred to as the control mode: Simplex employs a single I/O pack and a single network connection. TMR employs three I/O packs, each with one network connection. IS220PGENH1A Installation Securely mount the terminal board of choice. Insert one PGEN I/O pack for simplex or three PGEN I/O packs for TMR directly into the terminal board connectors. Use the threaded studs next to the Ethernet ports to mechanically secure the packs. The studs fit into a terminal board-specific mounting bracket. The bracket should be positioned so that no right angle force is applied to the DC-37 pin connector between the pack and the terminal board. The adjustment should only be needed once during the product's lifetime. Connect only one Ethernet cable. The pack can be used with either port. Connect the pack to power by plugging in the connector on the pack's side. Because the I/O pack has inherent soft-start capability that controls current inrush on power application, it is not necessary to disconnect power from the cable before plugging it in. Configure the I/O pack as needed using the ToolboxST application. Processor features Processor with high speed, RAM, and flash memory Two 10/100 Ethernet ports with connectors that are completely independent of one another Reset circuit and hardware watchdog timer Sensor for local ambient temperature LED status indicators Electronic identification and the ability to read IDs from other boards Significant programmable logic to support the acquisition board Soft start/current limiter input power connector Power supplies on-site, including sequencing and monitoring Auto-Reconfiguration The Auto-Reconfiguration feature allows the operator to replace I/O packs without having to manually reconfigure each pack or module. When the controller detects an I/O pack booting with a different configuration and the Auto-Reconfiguration feature is enabled, a reconfiguration file is automatically downloaded from the controller to the I/O pack. The bootload, baseload, firmware, and parameters are all reconfigured. Unless it already has the latest version, each I/O pack is updated with the current configuration that matches the configuration used by the controller. While an Auto-Reconfiguration is running, the controller will not allow a reboot until the Auto-Reconfiguration is complete. Other I/O pack downloads cannot be started while it is being Auto-Reconfigured. Auto-Reconfiguration only performs diagnostics if an I/O pack is already running. Turbine-Generator Monitoring Hardware An analog filter acquisition board is part of the PGEN application-specific hardware (BPAIH3). To improve analog-to-digital resolution, the analog filter acquisition board provides signal conditioning to center and amplify the signal. For three mechanical power sensors and three CT currents, the PGEN accepts analog input signals from the terminal board. An analog multiplexer block, several gain and scaling sections, and a 16-bit analog-to-digital converter comprise the analog input section (ADC). Depending on the input configuration, the three analog mechanical power inputs can be configured as 5 V, 10 V, or 4-20 mA scaled signals. The three current inputs are brought through 250 burden resistors on the terminal board if configured as 4-20 mA signals. At 20 mA, this resistance produces a 5 V signal. When configured for current inputs, the terminal board includes a 250 burden resistor that produces a 5 V signal at 20 mA. Power Load Unbalance Overspeed Control The Power Load Unbalance (PLU) function measures the difference between per unit steam turbine power and per unit generator power based on generator current.

A PLU event occurs when the turbine per unit power is 40% greater than the generator power and the difference meets both the rate of change and the duration requirements. When a PLU event is detected, the steam turbine control and intercept valves (CVs) are closed to reduce power. The Iopack (PGEN) and the (TGNA) terminal board monitor the PLU. The PLU function can be used in either a TMR or a Simplex configuration. The steam turbine CV and IV valves are controlled by the Mark VIe Digital Output IOpack, PDOA, and TRLY (Simplex, H1F TMR) (TRLY) or terminal board. The PGEN controls the relay state on the PDOA. A peer-to-peer multicast packet that provides a fast communication path improves the control of the relays in the PDOA. The fast communication path runs alongside the normal pack-to-pack communication, which is routed through the signal space by the controller to transfer relay commands. The multicast path is only used to send commands to the relays. IS220PGENH1A Diagnostics The following self-diagnostic tests are performed by the pack: A power-on self-test that includes RAM, flash memory, Ethernet ports, and most processor board hardware checks. Constant monitoring of internal power supplies for proper operation A check of the terminal board, acquisition board, and processor board electronic ID information to confirm that the hardware set matches, followed by a check that the application code loaded from flash memory is correct for the hardware set. Hardware limit checking is performed on each analog or current input based on preset high and low levels near the end of the operating range. If this limit is exceeded, a logic signal in signal space is set to Unhealthy, and the unhealthy signal is forced to zero volts or mA. If the signal returns to its limits, the signal state returns to Healthy. If any of the signals is abnormal, the logic signal L3DIAG-PGEN is activated. System limit checking is performed on each input based on configurable high and low levels. These limits can be used to generate alarms, enable/disable devices, and as latching/non-latching switches. Precision reference voltages are included in each scan by the analog input hardware. The measured values are compared to the expected values to confirm the health of analog to digital circuits.

  • Basler Electric CLASS 300 EQUIPMENT MVC-300 ELECTRONIC MANUAL VOLTAGE CONTROL
  • Basler Electric BE1-67 DIRECTIONAL OVERCURRENT RELAY
  • Basler Electric AEM-2020 and CEM-2020 Expansion Modules
  • Basler Electric MVC-300 Electronic Manual Voltage Control
  • Basler Electric BE1-60 Voltage Balance Relay
  • Basler Electric BE1-50BF Breaker Failure Relay
  • Eaton Power Defense molded case circuit breaker
  • Eaton Magnum with Power Xpert Release trip units
  • Eaton Tripp Lite series power conditioners
  • Eaton Tripp Lite series medical-grade isolation transformers
  • Eaton Tripp Lite series isolation transformers
  • Eaton Sag Ride-Through power conditioner
  • Eaton Power-Sure 700
  • Eaton PDI Current Limiting Reactor
  • Beckwith الكهربائية M-6280A الرقمية مكثف التحكم بنك
  • Beckwith الكهربائية M-4272 نظام نقل الحافلات الرقمية
  • بيكويث الكهربائية M-3420 مولد حماية ريلي
  • وحدة Beckwith Electric M-0193B Syncrocloser®
  • بيكويث الكهربائية M-3520 Intertie حماية ريلي
  • إيتون MTL 9470-ET/G جيجابيت نطاق إيثرنت آمن جوهريا
  • ريلاي حماية سلسلة Basler Electric ES
  • باسلر الكهربائية BE1-40Q فقدان الإثارة ريلي
  • لوحة عرض عن بعد لـ Basler Electric RDP-110
  • منظم الجهد الرقمي Basler Electric BE2000E
  • نظام التحكم الرقمي في الإثارة ديكس-150 من باسلر الكهربائي
  • باسلر الكهربائية APR 63-5 تنظيم الجهد
  • باسلر الكهربائية BE1-27. BE1-59. BE1-27/59. ريلي الجهد
  • Eaton MTL RugiCAM-IP high definition intrinsically safe ethernet camera
  • Eaton MTL Intrinsically Safe Power Supplies
  • Eaton MTL ExLAN intrinsically safe ethernet OEM interface
  • Eaton 9661-ETW MTL intrinsically safe ethernet to serial 4 port communication module
  • Eaton MTL SUM5 Smart Universal Marshalling
  • Eaton MTL 9474-ET/ETG and BxLAN-OEM intrinsically safe ethernet barriers
  • Eaton MTL 9460-ET range Intrinsically safe Ethernet products
  • Eaton MTL 9461-ET Intrinsically Safe Serial to Ethernet Gateway
  • Eaton MTL 9466-ET Intrinsically Safe Managed Ethernet Switch
  • Eaton MTL 9468-ET Intrinsically Safe Ethernet Isolator
  • Eaton MTL 9460-ET intrinsically safe ethernet products
  • Eaton MTL 9471-ET(G) Intrinsically Safe Gigabit Ethernet 4 Port Serial Gateway
  • Eaton MTL 9475-ET(G) Intrinsically Safe Gigabit Ethernet Dual Port Media Converter Switch
  • Eaton MTL 9476-ET(G) Intrinsically Safe Gigabit Ethernet 6 Port Managed Switch
  • Eaton MTL 9478-ETG MTL Intrinsically Safe Gigabit* Ethernet Galvanic Isolator
  • Eaton MTL 9479-ET(G)-CSL CSL Intrinsically Safe Gigabit Ethernet WLAN AP / Bridge
  • Beckwith Electric M-0067E Tapchanger Control
  • Beckwith Electric M-2001C Digital Tapchanger Control
  • Beckwith Electric M-2001D Digital Tapchanger Control
  • Beckwith Electric M-2017 Capacitor Bank Discharge Tool
  • Beckwith Electric M-2980A Weatherproof Capacitor Control Cabinet
  • Beckwith Electric M-6283A Three Phase Digital Capacitor Bank Control
  • باسلر الكهربائية DGC-2020HD جهاز تحكم المولدات الرقمية
  • باسلر الكهربائية DGC-2020 جهاز تحكم المولدات الرقمية
  • نظام التحكم الرقمي في الإثارة ديكس-400 من باسلر الكهربائي
  • باسلر الكهربائية BE1-81O / U ريلي التردد الرقمي
  • نظام حماية مولد باسلر الكهربائي BE1-GPS100
  • نظام التحكم الرقمي في الإثارة ديكس 450 من باسلر الكهربائي
  • نظام التحكم الرقمي في الإثارة ديكس-200 من باسلر الكهربائي
  • باسلر الكهربائية DECS-200N نظام التحكم في الإثارة الرقمية القسرية السلبية
  • إيتون F880 طاقة الحافلة الميدانية الزائدة لنظام التحكم Yokogawa CENTUM 3000 R3
  • إيتون F890 إمدادات الطاقة الميدانية الزائدة
  • إيتون T300 المحمولة 31 وظيفة راديو التحكم عن بعد
  • إيتون MTL F880 8 قطاع زائد الميدان الحافلة إمدادات الطاقة
  • إيتون 450U-E مودم إيثرنت لاسلكي وخادم الأجهزة
  • إيتون تريب لايت سلسلة مفاتيح شبكة إيثرنت الصناعية
  • إمدادات الطاقة FISCO الزائدة Eaton MTL
  • محطات الحافلات الميدانية Eaton MTL
  • مركز الطاقة الحافلة الميدانية Eaton MTL
  • محول إيتون MTL Ex IC للعمل الحي
  • إيتون FCS-9000 مجموعة صناديق التقاطع
  • صناديق تقاطع عملية إيتون MTL
  • إيتون MTL4854 متعدد المودم هارت متعدد
  • Eaton JOCKEY Touch™ وحدة تحكم مضخة جوكي القائمة على المعالجة الدقيقة
  • إيتون MTL4850 و MTL4854 هارت® متعددات
  • إيتون MTL4850-TR تريكونيكس 4850 هارت® متعدد
  • إيتون 245U-E نطاق إيثرنت اللاسلكي
  • حماية محرك إيتون MP-4000
  • أنظمة اتصال Eaton MTL4851 و MTL4852 HART®
  • Beckwith Electric M-6280A Digital Capacitor Bank Control
  • Beckwith Electric M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-3420 Generator Protection Relay
  • Beckwith Electric M‑0193B Syncrocloser® Unit
  • Beckwith Electric M‑3520 Intertie Protection Relay
  • Eaton MTL 9470-ET/G Gigabit intrinsically safe ethernet range
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler Electric RDP-110 Remote Display Panel
  • Basler Electric BE2000E Digital Voltage Regulator
  • Basler Electric DECS-150 Digital Excitation Control System
  • Basler Electric APR 63-5 Voltage Regulator
  • Basler Electric BE1-27. BE1-59. BE1-27/59. Voltage Relay
  • Basler Electric DGC-2020HD Digital Genset Controller
  • Basler Electric DGC-2020HD Digital Genset Controller
  • Basler Electric DGC-2020 Digital Genset Controller
  • Basler Electric DECS-400 Digital Excitation Control System
  • Basler Electric BE1-81O/U Digital Frequency Relay
  • Basler Electric BE1-GPS100 GENERATOR PROTECTION SYSTEM
  • Basler Electric DECS-450 Digital Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-200N Negative Forcing Digital Excitation Control System
  • Eaton F880 redundant fieldbus power for Yokogawa CENTUM 3000 R3 Control System
  • Eaton F890 Redundant fieldbus power supply
  • Eaton T300 Portable 31-Function Radio Remote Control
  • Eaton MTL F880 8 Segment Redundant Fieldbus Power Supply
  • Eaton 450U-E Wireless Ethernet Modem and Device Server
  • Eaton Tripp Lite Series Industrial Ethernet Network Switches
  • Eaton MTL redundant FISCO power supplies
  • Eaton MTL fieldbus terminators
  • Eaton MTL fieldbus power hub
  • Eaton MTL Ex ic adaptor for live working Ex ic spurs
  • Eaton FCS-9000 range Junction boxes
  • Eaton MTL Process Junction Boxes
  • Eaton MTL4854 Multi-modem HART Multiplexer
  • Eaton JOCKEY Touch™ Microprocessor Based Jockey Pump Controller
  • Eaton MTL4850 SIL3 HART Multiplexer
  • Eaton MTL4850 and MTL4854 HART® Multiplexers
  • Eaton MTL4850-TR Triconix 4850 HART® multiplexer
  • Eaton 245U-E Wireless Ethernet Range
  • Eaton MP-4000 motor protection
  • Eaton MTL4851 and MTL4852 HART® connection systems
  • Eaton MP-3000 Motor Protection Relay
  • Eaton vacuum interrupter (EVI) technology
  • EATON FP-5000 Protective Relay
  • Phoenix Contact Multifunctional energy measuring devices
  • Phoenix Contact DALI module for building controller
  • Phoenix Contact Current monitoring
  • Phoenix Contact PSRcompact Safety Relays
  • Phoenix Contact TRIO POWER Power Supply
  • Phoenix Contact Buttons, switches, and indicator lights
  • Phoenix Contact 2864422 MINI MCR-SL-RPS-I-I - Repeater power supply
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?