RSTi-EP CPUs make it possible to incorporate the entire PACSystems programming suite in standalone
applications or as auxiliary control in larger process applications that use RX3i. They allow the
User to leverage the power and flexibility of PACSystems in smaller applications.
At a high level, CPE100/CPE115 supports real-time application status, remote diagnostics and:
▪ Dual LAN interfaces with four Ethernet ports
▪ Built-in RS-232. RS-485 serial port
▪ Support for a range of communications protocols, including PROFINET
▪ Up to 1 MB of non-volatile user memory.
▪ All in just 1.5” (38.1mm) of DIN rail space.
CPE100/CPE115 supports two independent 10/100 Ethernet LANs. LAN1 has only one port and is
dedicated to highspeed Ethernet and whereas LAN2 is comprised of three switched ports (labelled as
2. 3 & 4) configurable as either a second embedded Ethernet controller or an embedded PROFINET
controller. All four ports are located on the front panel of the CPU.
The Ethernet controller Interface of CPE100/CPE115 provides Transmission Control Protocol and
Internet Protocol (TCP/IP) communications with other control systems, host computers running the
Host Communications Toolkit or programmer software, and computers running the TCP/IP version of
the programming software. These communications use the Service Request Transport Protocol
(SRTP), Modbus TCP, and Ethernet Global Data (EGD) protocols over a four-layer TCP/IP (Internet) stack.
Access to DeltaV Live graphics, DeltaV Operate graphics, and
the alarms and history collection from EIOC control modules
follows the same rules and mechanisms as control modules
running in the controllers in a DeltaV System.
The EIOC is a big pipe for the integration of process data from
3rd party Ethernet Devices, such as PLCs and smart field devices
such as Intelligent Field Devices (IFDs) and Intelligent Electronic
Devices (IEDs). A network of these Ethernet Devices can be
directly connected to the EIOC. The Ethernet Devices can
communicate to the EIOC using one of five protocols;
Modbus TCP, EtherNet/IP, IEC61850 MMS, OPC UA client
and EtherNet/IP Control Tag Integration. The EIOC connects
directly into the DeltaV Control Network and can be placed
remotely in an enclosure in the field.
Emerson | IC220TBK203 | Terminal Strip Set, Spring Style |
Emerson | IC220TBK204 | Terminal Strip Set, Spring Style |
Emerson | IC220TBK206 | Terminal Strip Set, Spring Style |
Emerson | IC220ACC201 | Relay Module Isolation Set |
Emerson | IC220ALG630 | Analog In 16 Bit Thermocouple 2 Channels |
Emerson | IC220ALG322 | Analog Out 13 Bit Voltage 2 Channels |
Emerson | IC220MDL643 | Input 24 VDC Positive Logic 8 Points |
Emerson | IC220MDL644 | Input 24 VDC Positive Logic 16 Points |
Emerson | IC220MDL753 | Output, 24 VDC Positive Log ic 0.5A, 8 Points |
Emerson | IC220MDL754 | Output, 24 VDC Positive Logic 0.5A, 16 Points |
Emerson | IC220MDL930 | Output, Relay 3.0A 1 Point |
Emerson | IC220MDL940 | Output, Relay 3.0A 4Point |
Emerson | IC220MDD841 | Absolute Encoder Input 4 In/4 Out 24 VDC |
Emerson | IC220PB1002 | Profibus-DP V1, Network Interface Unit |
Emerson | IC220PWR003 | Power Terminal Fused with Diagnostics 24 VDC |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com