Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Emerson S-series Serial Interface Introduction

From:Emerson | author:Mr.Chen | Time :2025-08-15 | 2 view: | Share:

The DeltaV™ S-series Serial Interface provides a connection between the DeltaV system and other devices.

• Provides seamless information interface

• Plug-and-play ease of use

• Extends the life of existing equipment

• 1:1 redundancy for Serial Interface I/O cards

• Automatic switchover

Introduction

The S-series Serial Interface provides a connection

between the DeltaV™ system and devices that support a

serial protocol, such as Modbus or Allen Bradley’s Data

Highway Plus.

The S-series Serial Interface is supplied with Modbus

software drivers pre-loaded. Additional drivers are available

to allow a wide variety of devices to be integrated directly

into the DeltaV controller’s I/O subsystem. Data can be used

by control modules or communicated to workstations as

SCADA tags for display and/or historizing. Like all DeltaV I/O,

the Serial Interface may be added online while the rest of

the controller I/O is powered up and in use.

DeltaV Serial Interface can also be installed as a redundant

pair for critical applications needing the highest availability.

Benefits

Provides seamless information interface. Using

the Serial Interface with the DeltaV system, you gain an

extended view of your entire plant. All serial information

from 3rd party systems, analyzers, PLC’s, is readily available

for display at the Operator Interface.

When connected to a PLC, DeltaV software may pass

supervisory information to the PLC facilitating the

coordination of control strategies across systems.

Plug-and-play easy to use. Plug-and-play installation

saves money. The Serial Interface works just like other

DeltaV I/O interfaces. It fits into any available slot on the

controller I/O carrier. There are no dipswitches. Just plug it in!

The DeltaV controller auto-senses the Serial Interface and

presents the configuration options. Online help makes this

interface a snap to configure. After a simple point-and-click

configuration exercise, your integrated solution is up and running.

Extends the life of existing equipment. Enhance existing

capabilities—don’t replace them. Many plants have a variety

of devices already installed. With the Serial Interface you are

able to effectively interface a DeltaV system with existing

PLCs or other serial devices. This means that you can layer

the state-of- the-art process control offered by a DeltaV

system on to the devices you already have in place.

1:1 Redundancy for Serial I/O cards. You can add

Serial interfaces as simplex cards or redundant pairs.

The interfaces automatically detect the presence of

the redundant terminal block and are autosensed by

the system as a redundant pair. There is no additional

configuration. Use redundant Serial interfaces with slave

devices that support redundant serial ports.

Automatic switchover. Should a primary Serial

Interface card fail, the system automatically switches

to the “standby” card without user intervention. The

operator is given clear notification of a switchover at the

operator display. The standby card continually polls the

slave devices for diagnostic to confirm its ability to take

over communications.

  • ABB Process Panel PP245 3BSC690126R2 PP245B
  • GE Mark VIe & VIeS IS230PCAAH1B - Core Analog I/O Module
  • GE Mark VIe & VIeS IS230PCAAH1A Core Analog I/O Module
  • Emerson PMCSPANA/IH PMC Carrier Installation and Use Manual
  • Emerson PMCSPAN26E-010 Secondary PMC expansion
  • Emerson PMCSPAN26E-002 Primary PMC expansion
  • Emerson PMCSPAN16E-010 Secondary PCI expansion
  • Emerson PMCSPAN16E-002 Primary PCI expansion
  • A-B 1783-HMS4C4CGN Stratix 5400 Ethernet Managed Switches
  • A-B 1783-RA5TGC4G Stratix 4300 Remote Access Routers
  • A-B 1783-CMS10DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-CMS20DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-CMS20DP Stratix 5200 Ethernet Managed Switches
  • A-B 1783-HMS8S4CGN Stratix 5400 Ethernet Managed Switches
  • A-B 1783-CMS6B Stratix 5200 Ethernet Managed Switches
  • A-B 1783-RA5TGW Stratix 4300 Remote Access Routers
  • A-B 1783-RA2TGWC4G Stratix 4300 Remote Access Routers
  • A-B 1783-US8T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US5TG/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-RA2TGW Stratix 4300 Remote Access Routers
  • A-B 1783-US8T/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US6T2F/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US4T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5TG Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US4T1H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2TG2H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US6T2TG2F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US4T1H/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US14T2S Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US7T1H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US16T2S Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-RA2TGC4G Stratix 4300 Remote Access Routers
  • A-B 1783-US16T/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US7T1F/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-RA2TGB Stratix 4300 Remote Access Routers
  • A-B 1783-LMS5 Stratix 2500 Ethernet Lightly Managed Switches
  • A-B 1783-US7T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US4T1F Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US16T Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US8T Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H/A Stratix 2000 Ethernet Unmanaged Switches—Series A
  • A-B 1783-US4T1F/B Stratix 2000 Ethernet Unmanaged Switches—Series B
  • A-B 1783-US8TG2GX Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US6T2H Stratix 2000 Ethernet Unmanaged Switches
  • A-B 1783-US5T 5 Port Unmanaged Switch
  • MOOG D138-002-002 Industrial Control Module
  • MOOG D138-003-001 Industrial Control Module
  • MOOG CA98502-001 Accessories for Ruggedized Motion Controller
  • MOOG D691-078D servo valve
  • MOOG CA65866-001 MSD Motion Controller
  • MOOG C43148-001 QD10 16/16 Digital l/0 module
  • MOOG D138-002-012 Main control unit
  • MOOG CA94286-001 Accessories for Ruggedized Motion Controller
  • MOOG D136-001-008 MSCI MSD Motion Controller
  • MOOG B95906-001 MSCI Motion Controller
  • MOOG B95865-001 CAN Termination Resistors
  • MOOG QEBUS-CAN Module
  • MOOG D136-003-001 Interfaces of Ruggedized Motion Controller
  • MOOG RDI0 16/16 Digital Module
  • MOOG D136-003-004 Interfaces of Ruggedized Motion Controller
  • MOOG D391-001-003 MSD MOTION CONTROLLER
  • MOOG D138-002-003 Industrial Control Module
  • MOOG MSC-R-10 16/8 Digital and PT100 Module
  • MOOG CB08987-001 Ruggedized Motion Controller
  • MOOG RDISP 22 Operator Panel DISPLAYS
  • MOOG D136-003-002 Interfaces of Ruggedized Motion Controller
  • MOOG CA65865-001 MSCl Motion Controller
  • MOOG B95863-001 CAN Connection Cables
  • MOOG QA10 16/4 Analog Module
  • MOOG D136-006-001 EtherCAT slave interface
  • MOOG D391-001-001 MSD MOTION CONTROLLER
  • MOOG D136-003-005 Interfaces of Ruggedized Motion Controller
  • MOOG D137-004-003 TFT Touch screen display
  • MOOG D138-002-003 Industrial Control Module
  • MOOG D138-003-010 Industrial Control Module
  • MOOG CB03223-001 Accessories for Ruggedized Motion Controller
  • MOOG B95864-001 CAN Termination Resistors
  • MOOG QD10 16/16 Digital Module
  • MOOG D391-001-002 MSD MOTION CONTROLLER
  • MOOG D138-001-010 Industrial Control Module
  • MOOG D138-001-005 Industrial Control Module
  • MOOG D138-001-002 Industrial Control Module
  • MOOG D138-001-001 Industrial Control Module
  • MOOG D137-002-001 Digital I/O modules
  • MOOG QEBUS-CAN Extension module
  • MOOG D137-001-010 Connection modules
  • MOOG D137-001-004 Digital I/O modules for E-Bus
  • MOOG D137-001-007 Digital extension module
  • MOOG G391-001-001 MSD Motion Controller
  • MOOG D138-002-001 Motion Controller
  • MOOG D137-004-004 TFT Touch screen display
  • MOOG D136-002-005 Ruggedized Motion Controller Interface
  • MOOG D137-001-006 Digital extension module
  • MOOG D136-002-004 Ruggedized Motion Controller Interface
  • MOOG D137-004-006 TFT Touch screen display
  • MOOG G391-001-002 MSD Motion Controller
  • MOOG D137-004-005 TFT Touch screen display
  • MOOG D137-001-005 Digital extension module
  • MOOG D136E001-001 Programmable Processor Module
  • MOOG D138-006-001 operation panel
  • MOOG G122-829-001 Programmable Processor Module
  • MOOG G761-3002B Industrial servo valves
  • MOOG T161-902A-00-B4-2-2A Servo Controller
  • MOOG M128-010-A001B DC Power Module
  • MOOG G391-001-003 MSD Motion Controller
  • MOOG D138-002-002 Motion Controller
  • MOOG D137-001-011 Digital extension module
  • MOOG D136-002-003 Ruggedized Motion Controller Interface
  • MOOG D136-002-002 Ruggedized Motion Controller Interface
  • MOOG D136-001-008a Ruggedized Motion Controller Interface
  • MOOG D136-001-007 Ruggedized Motion Controller Interface
  • MOOG D136-001-001 Ruggedized Motion Controller Interface
  • MOOG 914-GBE Gigabit Ethernet (GbE) Media Converter
  • MOOG 914-0300-00 ADVANCED MODULAR MULTIPLEXER SYSTEM
  • ABB UCD224A103 digital input/output module
  • ABB PDD205A0121 power distribution device
  • ABB PDD205A1121 power distribution device
  • ABB DSDX453 Digital input/output (DIO) expansion card
  • ABB DSPC454 Processor Board
  • ABB 81EU01E-E Input Module
  • ABB TK457V050 Temperature Controller
  • ABB DSRF197K01 Ethernet communication module
  • ABB TK802F power supply cable
  • ABB 3BHE039203R0101 IGCT module board
  • ABB 3BHB004027R0101 IGCT module board