Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Emerson S-series Serial Interface Introduction

From:Emerson | author:Mr.Chen | Time :2025-08-15 | 161 view: | Share:

The DeltaV™ S-series Serial Interface provides a connection between the DeltaV system and other devices.

• Provides seamless information interface

• Plug-and-play ease of use

• Extends the life of existing equipment

• 1:1 redundancy for Serial Interface I/O cards

• Automatic switchover

Introduction

The S-series Serial Interface provides a connection

between the DeltaV™ system and devices that support a

serial protocol, such as Modbus or Allen Bradley’s Data

Highway Plus.

The S-series Serial Interface is supplied with Modbus

software drivers pre-loaded. Additional drivers are available

to allow a wide variety of devices to be integrated directly

into the DeltaV controller’s I/O subsystem. Data can be used

by control modules or communicated to workstations as

SCADA tags for display and/or historizing. Like all DeltaV I/O,

the Serial Interface may be added online while the rest of

the controller I/O is powered up and in use.

DeltaV Serial Interface can also be installed as a redundant

pair for critical applications needing the highest availability.

Benefits

Provides seamless information interface. Using

the Serial Interface with the DeltaV system, you gain an

extended view of your entire plant. All serial information

from 3rd party systems, analyzers, PLC’s, is readily available

for display at the Operator Interface.

When connected to a PLC, DeltaV software may pass

supervisory information to the PLC facilitating the

coordination of control strategies across systems.

Plug-and-play easy to use. Plug-and-play installation

saves money. The Serial Interface works just like other

DeltaV I/O interfaces. It fits into any available slot on the

controller I/O carrier. There are no dipswitches. Just plug it in!

The DeltaV controller auto-senses the Serial Interface and

presents the configuration options. Online help makes this

interface a snap to configure. After a simple point-and-click

configuration exercise, your integrated solution is up and running.

Extends the life of existing equipment. Enhance existing

capabilities—don’t replace them. Many plants have a variety

of devices already installed. With the Serial Interface you are

able to effectively interface a DeltaV system with existing

PLCs or other serial devices. This means that you can layer

the state-of- the-art process control offered by a DeltaV

system on to the devices you already have in place.

1:1 Redundancy for Serial I/O cards. You can add

Serial interfaces as simplex cards or redundant pairs.

The interfaces automatically detect the presence of

the redundant terminal block and are autosensed by

the system as a redundant pair. There is no additional

configuration. Use redundant Serial interfaces with slave

devices that support redundant serial ports.

Automatic switchover. Should a primary Serial

Interface card fail, the system automatically switches

to the “standby” card without user intervention. The

operator is given clear notification of a switchover at the

operator display. The standby card continually polls the

slave devices for diagnostic to confirm its ability to take

over communications.

  • Bently TTL70259 LEMO-BNCTTLTach/Keyphasorcable
  • Bently MAGF0104 Accelerometermagneticbase
  • Bently DCCA0041 DCcaradapter
  • Bently CABU0213 USBdatatransfercable
  • Bently ACCL0561 Right-angledaccelerometer
  • Bently ACCL0547 Straightaccelerometer
  • Bently 108M4049-02 SCOUTprogrammedUSBthumbdrive
  • Bently 108M3240 SCOUT140-Exfour-channelportable datacollector
  • Bently 100M5828 SCOUT/Vb Series Hard Case
  • Bently VBMR0222 Stainless safety rings (1 pair)
  • Bently DTC70262 Neoprene dust cover
  • Bently BATT0575 Battery pack ATEX
  • Bently MAGM0064 Accelerometer magnetic base Male connection
  • Bently KTTC0331 Triaxial sensor kit
  • Bently AP3500S2-Z1 Low frequency accelerometer
  • Bently AP3500T2-Z1 Low frequency accelerometer
  • Bently AM3100T2-Z2 General purpose accelerometer
  • Bently AS3100S2-Z2 General purpose accelerometer
  • Bently SUNW0401 Network upgrade
  • Bently CLK20399 Aditional L2 user activation
  • Bently DGLU0219 Dongle for software seat or license mobility
  • Bently 3071/01 System 1 software
  • Bently 108M4069 Laser TachZone 2 rated
  • Bently 108M4067 Arpl15 Oring
  • Bently 108M4066 Circlips-20Mm Stainless
  • Bently 108M4064 Laser Tacho Holder
  • Bently CBBLO026 Carrying casefor the kit
  • Bently CB5R0025 Sensor Cable Five meters, red
  • Bently CB5G0024 Sensor CableFive meters,green
  • Bently MAGA0063 Laser magneticstand
  • Bently CBL50216 Laser cable Five meters
  • Bently 113M5529-01 Reflective tapeOne roll, 60 cm
  • Bently LASA0315 LaserZone 2 rated
  • Bently 110M8172-012 LEMO-BNC TTLTach/Keyphasor cable
  • Bently 108M4045 SCOUT quick start guide
  • Bently PLEU0229 Europe - Category Cpower plug
  • Bently PLHK0245 Hong Kong/UK Category-G power plug
  • Bently PLAU0228 Australia/New Zealand /China - Category Mpower plug
  • Bently PLSAO241 South Africa/India -Category D power plug
  • Bently PLUS0230 USA/Canada - CategoryA power plug
  • Bently 109M2384-01 Neck strap with SensorKeeper
  • Bently MVBX0250 Reference_Guide
  • Bently 113M5585 Accelerometermagnetic base
  • Bently CBVB0032 carrying bag
  • Bently CBTB0278 SCOUT instrument
  • Bently CBCC0027 or138M7748 Triple BNC adapter
  • Bently CABUO213 Transducer cable
  • Bently 110M8172-012 USB data transfer cable
  • Bently CABB0560 BNC to BNC Cable,1meter
  • Bently 108M4044 AC power adapter
  • Bently ACCLO561 or200350* Right-angledaccelerometer or straight accelerometer
  • Bently ACCLO547 or200350* Straight accelerometer
  • Bently 108M3240 SCOUT140Ex four channel portable data collector
  • Eaton F30 Ex ic Adaptor ATEX & IECEx Approved
  • ABB DRIVEMONITOR VERSION 4000 DRIVE MODULE RBOX316-ABB-00
  • ABB VACUUM CONTACTOR VSC7 SCO IEC 60470 400A 3POLE 220-250V 50/60Hz
  • Johnson Controls MS-NAE5512-1 Supports two N2 or two BACnet MS/TP (RS-485) trunks
  • Johnson Controls MS-NAETUNL-8 ToggleTunnel utility for converting an NAE55/NIE55 to an NAE55 model
  • Johnson Controls MS-MECVT-0 MS/TP to Ethernet Converter
  • Johnson Controls MS-SECVT-0 Serial to Ethernet Converter
  • Johnson Controls AS-XFR100-1 Power transformer
  • Johnson Controls AS-XFR100-1 Power transformer
  • Johnson Controls MS-FEC2621-0U FEC26 Field Equipment Controllers
  • Johnson Controls MS-FEC2611-0U FEC26 Field Equipment Controllers
  • Johnson Controls AS-XFR010-1 Power transformer
  • Johnson Controls MS-NAE5521-1 Supports a LONWORKS trunk and two N2 trunks or two BACnet MS/TP (RS-485) trunks
  • Johnson Controls MS-NAE5510-1 NAE55 Network Automation Engines
  • Johnson Controls IOM3731 INSTALLATION MANUAL
  • ALSTOM MCRI1 - MODULE BOARD FOR SETTING SETTINGS AND CURRENT REGULATION
  • ALSTOM BCEA1 - TERMINAL BOARD OF 8 ANALOGUE INPUT SIGNALS
  • ALSTOM E64L1- LOGIC INFORMATION ACQUISITION BOARD
  • ALSTOM BCEL2 - TERMINAL BOARD FOR 12 LOGIC INPUT SIGNALS
  • ALSTOM BCSR1 - TERMINAL BOARD OF 8 LOGIC OUTPUT SIGNALS
  • ALSTOM ESVI1 - INPUT/OUTPUT BOARD FOR CURRENT AND VOLTAGE SIGNALS
  • ALSTOM MDEX1 – EXCITATION CURRENT MEASUREMENT AND CALIBRATION BOARD
  • ALSTOM IRVI20 - REGULATION INTERFACE BOARD
  • ALSTOM RDSP1 – BOARD FOR ADJUSTING DIGITAL SIGNAL PROCESSES
  • ALSTOM ARTN1 - DIGITAL INDICATION BOARD FOR VOLTAGE REGULATION
  • ALSTOM FRTN2 - BOARD OF DIGITAL INDICATION OF VOLTAGE REGULATION
  • ALSTOM CPRM1 - SINGLE-PHASE POWER REGULATION BOARD
  • ALSTOM AMS42 - POWER SUPPLY BOARD
  • DEIF PPM-3 SG PROTECTION AND POWER MANAGEMENT COMPLETE SET
  • DEIF PPM-3 DG Protection and Power Management
  • DEIF S8VK-S48024 Power supplies
  • DEIF S8VK-R20 Redundancy units
  • DEIF S8VK-T96024 Power supplies
  • Deif GPU-3 Generator Protection Unit 0-20MA
  • Deif Du-2 / Mkiii Multil neas Ppm Protecci n Y Gesti n de Energ a 100-690vac
  • DEIF AGC 222 & IOM 220 advanced genset controller
  • Deif Delomatic 4 DGU 0005 Generator Control System PCM 4-1, IOM 4-1, SCM 4-2
  • DEIF PPM-3-DG PROTECTION AND POWER MANAGEMENT MEAS.VOLTAGE:100-690VAC, 0.5MA
  • DEIF AGC Plant Management (Genset Controller) 100132445.10
  • Deif Delomatic 4 DGU 0002 Generator Control System PCM 4-1, IOM 4-1, SCM 4-2
  • DEIF 879.3C Dynamic Wind Sensor with MIC-4224 Display suit Marine
  • DEIF MDR-2 MULTI DIFFERENTIAL PROTECTION RELAY
  • Generator Control Unit Deif Delomatic 4 DGU 0001
  • DEIF DELOMATIC 4 DGU 0001 CONTROLLER
  • DEIF MTR-4-415 1200510024 Multi-transducer
  • Deif DPD 04057 Printed Circuit Board 1044230020F
  • DEIF AGC 252 advanced Genset Controller 2912420010.39 Options -C2-N
  • Deif AGC/GS/3.6 Automatic genset controller 600043767.80
  • Deif GPU/2/GS Generator Protection Unit
  • DEIF AGC-4/GS/4.4 Advanced Genset Controller Option-G5-G7-I1-M12-M13.6-N-J1
  • DEIF PPU-2-GS-100033222.50 PROTECTION AND POWER MANAGEMENT SYSTEM
  • DEIF PPU/2/GS Protection & Paralleling Unit + Operator Panel + Connector cable
  • DEIF PPU-2-GS-100059909.10 WITH DISPLAY AND CABLE PROTECTION
  • DEIF PPU-2-GS 600033613.10 WITH DISPLAY GENERATOR UNIT
  • Deif Delomatic-3 Generator Control Panel System Panel CP-1 | 1044220050D
  • Caterpillar Branded DEIF MCS2 Controller
  • Deif Paralleling & Protection Unit PPU-3 100121906.10 600V
  • A-B 20G11BC1K1JN0NNNNN PowerFlex Air Cooled 755 AC Drive
  • A-B 20P41AF452RA0NNN PowerFlex 452 A DC Drive
  • A-B 20GHAJC540JN0NNNNN PowerFlex Extra Tough 755 AC Drive
  • EPRO MMS6823 9100-00001-05 Displacement Monitor Module
  • GE LP-33 SERIES UPS DISPLAY & CONTROL PANEL LP33
  • GE CL06A300M IEC Contactor (50 Amp)
  • GE CR2962F2D Plugging Switch NIB
  • General Electric IC500A411DG2 Electrical Rectifier Semiconductor
  • GE IS200BICLH1AFE Interface Module 259B2431DB-G01 BICLH1A
  • General Electric 1253-0003-C4 Multilin Analog & I/O Board 369-A200
  • Ge Panametrics Crs-10-Mb Ultrasonic Flow Converter
  • GE PROPRIETARY IS215WEPAH2BB With IS210BPPCH1AD CONTROL BOARD
  • GE MULTILIN / 12P0-0001-P2 / Powerr Supply Board, 870500.DWG, 870501.DWG
  • GENERAL ELECTRIC PL19A129393G4 Auxiliary Receiver in Wall-mount Cabinet
  • GE CR306F002XAAA Nema-4 Coil 115-120V 60Hz 110-50Hz 600Vac Magnetic Contactor
  • General Electric 193x190bag02 ISOL P/S Board I93XI90BAG02 Computer board GE
  • GE Multilin / G6P3CH / Front Panel, G60 Generator Management Relay
  • GE MMY30-R1D26 DewPro MOISTURE TRANSMITTER