FBxWifi™
The optional FBxWifi communications enables you to
connect your laptop or tablet to the flow computer
through a secure wireless connection. Once connected
wirelessly, you can use FBxConnect configuration
software to view process values, edit configuration
parameters, and collect logs stored in the flow
computer – all from within the safe area.
Firmware
The base firmware in the FB2200 flow computer comes
with all the calculations, features and functionality
required to provide consistent measurement with
increased confidence for oil and gas metering and
control. The flow computer measures static pressure,
differential pressure or pulse frequency, and
temperature for up to two meter runs.
The flow computer performs flow calculations based
on the following set of user selectable global
calculations. To fully satisfy local requirements, the
engineering units are fully user-selectable between
either U.S. or metric, or a combination of each.
The firmware supports the following flow calculations:
▪ AGA 3 1992/2013 (volume, mass/density, and
mass/relative density)
▪ ISO 5167 1991/1998/2003 (orifice, Venturi, and nozzle)
▪ Rosemount 405C Compact Orifice and 1595
Conditioning Orifice Plate
▪ McCrometer V-Cone® and Wafer Cone®
▪ NUFLO™ Cone
▪ GOST 8.586 2005 (Orifice)
▪ AGA 7 2006 (pulsed turbine, PD, and ultrasonic)
▪ AGA 11 2013 (Coriolis pulses)
▪ Auto-Adjust™ meter
▪ AGA 9 (Multipath Ultrasonic)
▪ API 20.1 Liquid Allocation Measurement
▪ API 12.2 Calculation of Petroleum Quantities
The firmware supports the following property calculations:
▪ AGA 8 1994 (Detailed, Gross 1. and Gross 2)
▪ AGA 8 2017 Part 1 and Part 2 (GERG 2008)
Note: AGA8 Part 2 / GERG provides support for the
following pure gases (100%) as well as any
mixtures (0% to 100%): Nitrogen, Carbon
Dioxide, Hydrogen, Oxygen, Carbon
Monoxide, Water Vapor, Hydrogen Sulfide,
Helium, and Argon
▪ Speed of Sound calculated via AGA 10 and AGA 8 2017 Part 2
▪ NX-19 1962. MOD, VDI/VDE 2040. Miller
▪ ISO 12213 2006 (parts 2 and 3)
▪ SGERG 1991 (Std., Alt 1. Alt 2. and Alt 3)
▪ GOST 30319 2015 (Part 3)
▪ GPA 2172 2009 (including saturated vapor calculation)
▪ ISO 6976 1995 (superior and inferior, incorporating
Technical Corrigendum 2 [1997] and 3 [1999])
▪ AGA 5 2009
▪ API 11.1 Temperature and Pressure correction for
Crude Oils, Refined Products, and Lubricating Oils
▪ GPA 8217/API 11.2.4 Table E (formerly TP-27)
Temperature Correction for NGL and LPG
▪ GPA 8117/API 11.2.5 (formerly TP15) Vapor
Pressure and API 11.2.2. API 11.2.2M, API 11.1
Pressure Correction for NGL and LPG