Heat Load and Cooling
The heat load of the S2K Series controllers is dependent on the model as shown below:
Stepper Controller
Model SSI105: Heat Load = 20 Watts + (0.3 * current setting in percent) or 50 watts max.
Servo Controllers
Model SSI104: Heat Load = 25 watts + (35 * duty cycle) watts or 60 watts max.
Model SSI107: Heat Load = 35 watts + (65 * duty cycle) watts or 100 watts max.
Model SSI216: Heat Load = 50 watts + (150 * duty cycle) watts or 200 watts max.
Model SSI228: Heat Load = 60 watts + (280 * duty cycle) watts or 340 watts max
Model SSI407: Heat Load = 35 watts + (65 * duty cycle) watts or 100 watts max..
Model SSI420: Heat Load = 60 watts + (250 * duty cycle) watts or 310 watts max.
Duty cycle is defined as the percent of time the controller is at full rated output divided by the
total cycle time. The SSI104 and SSI107 controllers are designed to operate at full rated
current with only natural convection cooling at ambient temperatures up to 50°C. The
SSD104, SSD107, SSI104, SSI107, SSI216, SSI228, SSI407, SSI420 and STI105 models
have built-in fan cooling.
The controllers must be installed vertically for effective cooling. Allow a minimum clearance of
3 inches above and below the unit. A minimum of 2 to 3 inches clearance is also
recommended on the right and left sides of the unit where possible.
Note: For UL approved installation of the following controllers, maximum ambient
temperature is 40°C (104°F): IC800SSI216P2, IC800SSI216RP2, IC800SSI216D2,
IC800SSI216RD2, IC800SSI228P2, IC800SSI228RP2, IC800SSI228D2,
IC800SSI228RD2, IC800SSI407RS1, IC800SSI407RP2, IC800SSI407RD2,
IC800SSI420RP2, IC800SSI420RD2
Stepper Controller Electrical Specifications
The S2K Stepper Controller (IC800STI105xx) is suitable for use on a circuit capable of
delivering not more than 5,000 rms symmetrical amperes and 130 volts maximum when
protected by RK5 class 15A fuses. Table 2-2 summarizes the Stepper Controllers
maximum continuous input power requirements. The actual input power and current is a
function of the motor's operating point and the duty cycle.
We have the same series of models in stock.
If you don't find the model you need, please contact us and we will provide you with an official quotation!
GE V7865-ACC-603-RC VME Transition Module for V7865
GE VMIVME-4116 8-channel 16-bit digital-to-analog converter board
GE VMIVME-2210 Specifications
GE VMIVME-1128 128-bit High-Voltage Digital Input Board with Built-in-Test
GE XVB603 VME Single Board Computer
GE VMIVME-4132-010 32-Channel, 12-bit Analog Output Board with Built-In-Test
GE VMIVME-2540-300 24-Channel Intelligent Counter/Controller
GE VMIVME-4514A-000 16-Channel Scanning Analog I/O Board
GE VMIACC-5595-208 Specification
GE VMIVME-3122 High-Performance 16-bit Analog-to-Digital Converter
GE VMIVME-7805 VMEBus SBC Motherboard
GE VMIVME-2128 Output Module
GE VMIVME-3123 Specifications
GE VMIVME-7700 Ultra Low Voltage Intel® Celeron® VMEbus
GE VMIVME-5531M VMIVME-5531L Specifications
GE VMIVME-3100 analog-to-digital conversion module
GE VMIVME-2170A Isolated Digital Output Module
GE VMIVME-7740 VME Single Board Computer
GE VMIVME-2120 64-bit High-Voltage Digital Output Megamodule
GE VMIVME-4941 Quad-Channel Synchro/Resolver-to-Digital Converter
GE VMIVME-4116 8-channel 16-bit Digital-to-Analog Converter Board
GE VMIVME-7696-650 Pentium II Processor-Based VMEbus Single-Board Computer
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved