Introduction
The PACSystems RX3i family provides advanced diagnostics and high performance I/O.
With a modular design and multiple expansion options, RX3i is the perfect I/O solution for your process, hybrid,and discrete applications.
Modular, High-Speed Performance RX3i is a rack-based system with a wide range of modules covering digital, analog, and numerous other specialty
I/O types. These pluggable and hot-swappable modules allow you to customize the right mix of I/O,
with a variety ofvoltage ranges and current capacities supported to meet all your application needs.
Regardless of the I/O mix you choose, RX3i is built on high speed interfaces to provide rapid and consistent data transfer.
Highly Scalable
With the ability to pair I/O, RX3i allows you to scale your system with ease. In addition to I/O that you can put
on the main rack, you can expand locally or remotely to connect to additional racks of I/O. In fact, RX3i can support as
few as 8 I/O points and up to 32 thousand I/O points in a single system. With 7 to 16 slot backplanes and 1 slot expansion
options, you can create the perfect system to fit your needs.
The Build
To validate the project, the project code must be built. This step is also very useful for syntax checking;
all detected errors can be easily located with a simple mouse-click. The generated code is fully publicly documented and supported.
The code generator produces the code for each resource.
Best availability
Can your process controller keep up with system demands?
Many of today's controllers take ten milliseconds or more
to switchover in the event of a fault or other system event.
Often controllers are also limited in real I/O connections due to bottlenecks in overall data collection.
Eliminate delays by combining RX3i and PROFINET to get Gigabit speed everywhere
and bumpless (0 ms) switchover. Choose RX3i High Availability and prevent unexpected failure and costly downtime.
• Simple configuration, maintenance and operation
• Single point of connect no matter what distance
• Fewer external devices to purchase and configure, and fewer spare parts to maintain
• High-speed communication for real-time control
• Advanced asset management with Hart pass-thru I/O
Program development process
A resource contains several programming units called Program Organization Units (POUs).
POUs can be programs, functions or function blocks. Programs can be described in any of the five IEC 61131-3 languages plus Flow Chart.
GE Intelligent Platforms understands that equipment builders are continuously looking for
ways to improve the performance and flexibility of their equipment while reducing size and complexity.
Fast, easy-to-configure connectivity to GE’s PACSystems controllers and extensive range of I/O
options enables scalable machine automation and highly distributed modular machine designs.
The end result is high performance automation for the Industrial Internet.
The Mini Converter Kit consists of an RS-422 (SNP) to RS-232 Mini Converter integrated into a 6 foot (2 meter) serial extension cable,
and a 9-pin to 25-pin Converter Plug assembly.
The 15-pin SNP port connector on the Mini Converter plugs directly into the serial port connector on the programmable controller.
The 9-pin RS-232 port connector on the Mini Converter cable connects to an RS-232
compatible device.
Two LEDs on the Mini Converter indicate activity on the transmit and receive lines.
The Converter Plug is required to convert the 9-pin serial port connector on the Mini Converter to
the 25-pin serial port connector on an IC647 computer, an IBM® PC-XT, or a PS/2® Personal Computer.
The IC640 industrial computer requires an additional adapter (not supplied – please contact your local PLC distributor) for use with the Mini Converter.
Tables 1 and 2 list the Mini Converter pinouts. The direction of signal flow is with respect to the Mini Converter.
GE IC693ALG392RR High Density Analog Output, 8 Channels |
GE IC693ALG442 Analog Combo Module 4IN/2OUT |
GE IC693ALG442CA Conformal Coated Analog module, four in and two out. |
GE IC693ALG442LT Analog Combo Module 4IN/2OUT (LT) |
GE IC693ALG442RR Analog Combo Module, 4In/2Out |
GE IC693APU300 High Speed Counter (HSC) |
GE IC693APU300CA Conformal Coated High Speed Counter |
GE IC693APU300LT High Speed Counter (HSC) (LT) |
GE IC693APU300RR High Speed Counter (HSC) |
GE IC693APU301 1-axis APM motion controller module |
GE IC693APU301RR Axis Positioning Module (APM), 1 Axis, requires (1) or (2) CBL311 |
GE IC693APU302 2-axis APM motion controller module |
GE IC693APU302RR Axis Positioning Module (APM), 2 Axis, requires (1) or (2) CBL311 |
GE IC693APU305 I/O Processor Module |
GE IC693APU305RR Special I/O Processor |
GE IC693BEM320 I/O Link Interface Module (Slave) |
GE IC693BEM320RR I/O Link Interface Module |
GE IC693BEM321 I/O Link Interface Module (Master) |
GE IC693BEM321RR I/O Link Interface Module (Master) |
GE IC693BEM331 Genius Bus Controller (supports I/O and Datagrams) |
GE IC693BEM331CA Conformal Coated Genius Bus Controller |
GE IC693BEM331LT Genius Bus Controller (supports I/O and Datagrams) (LT) |
GE IC693BEM331RR Genius Bus Controller |
GE IC693CBK001 Cable Kit for High Density I/O Modules (includes CBL327 and CBL328) |
GE IC693CBK002 Cable Kit for High Density I/O Modules (includes CBL329 and CBL330) |
GE IC693CBK003 Cable Kit for High Density I/O Modules (includes CBL331 and CBL332) |
GE IC693CBK004 Cable Kit for High Density I/O Modules (includes CBL333 and CBL334) |
GE IC693CBL300 Rack Expansion Cable, I/O Expansion, 1 Meter |
GE IC693CBL301 Rack Expansion Cable, I/O Expansion, 2 Meters |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved