The ELX318x analog input terminal allows the direct connection of
intrinsically safe HART-capable field devices located in hazardous
areas classified zone 0/20 or 1/21. It supplies measuring transducers
located in the field and transmits their analog measuring signals
electrically isolated to the automation device.

Overload and open-circuit detection are signaled by the error LEDs,
furthermore LEDs inform about the status of the HART communication
and signal any communication errors. The EtherCAT Terminal indicates
the signal state by means of light emitting diodes.
The HART protocol (Highway Addressable Remote Transducer) enables
two-way communication through digital data transfer via the analog
4…20 mA wiring. In this way, in addition to the analog current signal,
further data can be exchanged with the field device via the
superimposed digital signal.
The HART communication can also be used for the FDT/DTM concept.
The TwinCAT FDT container enables the integration of field device
DTMs into TwinCAT Engineering, so that the device configuration and
diagnostic functions are available directly within the development
environment. As the FDT concept only supports 32-bit, it cannot be
used in the 64-bit TwinCAT XAE Shell.
The ELX3152-0090 analog input terminal allows the direct connection of
intrinsically safe field devices located in hazardous areas classified zone
0/20 or 1/21. It supplies measuring transducers located in the field and
transmits their analog measuring signals electrically isolated to the
automation device. The measuring range can be switched between 0...20
mA and 4...20 mA by software.
With a technical measuring range of ±107% of the nominal range, the
terminal also supports commissioning with sensor values in the limit range
and evaluation according to NAMUR NE43. The error LEDs indicate an
overload condition and wire breakage. The error LEDs indicate an overload
condition and wire breakage.
With the aid of the TwinSAFE SC technology (TwinSAFE Single Channel) it
is possible to make use of standard signals for safety tasks in any network
or fieldbus. To do this, EtherCAT I/Os from the areas of analog input,
position measurement or communication (4… 20 mA, incremental encoder,
IO-Link, etc.) are extended by the TwinSAFE SC function.
The properties typical for the signals and the standard functions of the I/O
components are retained. TwinSAFE SC I/Os differ optically from standard
I/Os by a yellow stripe on the front of the housing.
The TwinSAFE SC technology enables communication via a TwinSAFE protocol.
These connections can be distinguished from the usual secure communication
via Safety over EtherCAT.
The ELM360x EtherCAT Terminals are designed for the evaluation of IEPE
sensors (Integrated Electronics Piezo-Electric), which are mainly used for
vibration diagnostics and acoustics. The constant current feed can be set
to 0/2/4 mA. The input characteristics are also flexibly adjustable from
DC to 10 Hz in the CoE. The ELM360x basically measures voltages AC/DC
and in addition, the internal scaler function can be used if, for example,
an output in acceleration [m/s²] is desired. In voltage measurement mode
12 different measurement ranges from ±20 mV to ±10 V and 0 to 20 V
are adjustable.
Irrespective of the signal configuration, all ELM modules have the same
technological properties. The ELM360x modules for IEPE evaluation offer
a maximum sampling rate of 20.000 or 50.000 samples per second. IEPE
sensors are often connected via coaxial cables, therefore the ELM360x-0002
feature a BNC connector. The 2-pin version with push-in (ELM360x-0000)
on the other hand is ideal for industrial use where a plug is unplugged
less frequently for maintenance purposes and fast wiring is much more
important.