The EL3314-0090 analog input terminal allows four thermocouples
to be connected directly. The EtherCAT Terminal circuit can operate
thermocouple sensors using the 2-wire technology.
A microprocessor handles linearization across the whole temperature
range, which is freely selectable. Compensation for the cold junction
is made through an internal temperature measurement at the terminal.
The EL3314-0090 can also be used for mV measurement.

With the aid of the TwinSAFE SC technology (TwinSAFE Single
Channel) it is possible to make use of standard signals for safety
tasks in any network or fieldbus. To do this, EtherCAT I/Os from the
areas of analog input, position measurement or communication (4…
20 mA, incremental encoder, IO-Link, etc.) are extended by the
TwinSAFE SC function. The properties typical for the signals and the
standard functions of the I/O components are retained.
TwinSAFE SC I/Os differ optically from standard I/Os by a yellow stripe
on the front of the housing.
The TwinSAFE SC technology enables communication via a TwinSAFE
protocol. These connections can be distinguished from the usual
secure communication via Safety over EtherCAT.
The data from the TwinSAFE SC components is fed via a TwinSAFE
protocol to the TwinSAFE Logic, where it can be used in the context
of safety-relevant applications. Detailed examples confirmed/calculated
by the TÜV SÜD for the correct application of the TwinSAFE SC
components and the respective normative classifications can be found
in the TwinSAFE application manual.
The ED3274 analog input terminal enables the measurement of
temperatures with resistance thermometers (RTD) or thermocouples
(TC) on four channels. Each channel can be configured individually,
allowing for mixed operation of RTD and TC.
The measured values can be output as resistance or voltage values
or converted directly into a temperature. All common sensor types
are supported.
For temperature measurement with resistance thermometers, sensors
in a 2. 3. or 4-wire system can be connected. A cold junction
compensation is integrated in the terminal for temperature
measurement with thermocouples. This internal measurement can
be switched off so that an external cold junction can be used.
The ED series EtherCAT Terminals have push-in connection technology
which makes wiring easy and tool-free.
SEW EURODRIVE MC07B0005-5A3-4-S0 |
SIEMENS 6ES7 313-1AD03-0AB0 |
NEWALL E70 DP8 DIGITAL SENDING UNIT E702LSO LATHE |
NEWALL DP8 DIGITAL SENDING UNIT 8SC211000 CSS |
MITUTOYO RS-232C 09CAA402 CODE OUT UNIT |
Baumuller BUS21-15/30-31-020 |
Allen-Bradley 1756-OF4 BOX NO OPEN |
Sick AFM60A-S4NB018X12 Absolute Encoder 1059039 |
Siemens 6AV6 542-0BB15-2AX0 6AV6542-0BB15-2AX0 |
Beckhoff ELM3504-0000 |
OMRON CP1H-XA40DT1-D |
SEW EURODRIVE MDS60A0022-5A3-4-00 With DIO11A |
ALLEN-BRADLEY 1785-L40C D REV.E01 |
ALLEN-BRADLEY 2801-NL4 SER A - NIKON HS-14 |
HONEYWELL R4348B1016 |
PICIORGROS FTR-700H/D2.24.485 |
EUCHNER GSBF05R16-502 |
BAUMULLER WEBER WUS21-15/30-31-030 |
UNITRONICS V350-35-T38 |
HONEYWELL FF-SPE44TXG |
PHILIPS PM 9873A/01 TC linearizer |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved