The EL3214-0090 is the TwinSAFE SC version of the EL3214.
The EL3214-0090 analog input terminal facilitates the direct
connection of four resistance sensors. The measured resistance
value can either be output directly in ohms or transformed into
a temperature.
If the temperature at the measuring point is of interest, the
conversion from resistance to temperature can be carried out
in the terminal according to various sensor characteristics
(Pt100. Pt1000. NI120. NI1000. KTY types, etc.).

The EL3214-0090 can operate sensors using 2-wire and 3-wire
technology. The EtherCAT Terminals indicate their measurement
capability by means of light emitting diodes and status bits in the
EtherCAT process image. The EL3214-0090 supports TwinSAFE
Single Channel technology.
The TwinSAFE SC technology (TwinSAFE Single Channel) facilitates
the use of standard signals for safety-related tasks in any networks
or fieldbuses. To do this, EtherCAT I/Os from the areas of analog
input, angle and displacement measurement, or communication
(4 to 20 mA, incremental encoder, IO-Link, etc.) are extended by
the TwinSAFE SC function. The typical signal features and standard
functionalities of the I/O components are retained.
The HART communication can also be used for the FDT/DTM concept.
The TwinCAT FDT container enables the integration of field device DTMs
into TwinCAT Engineering, so that the device configuration and diagnostic
functions are available directly within the development environment.
As the FDT concept only supports 32-bit, it cannot be used in the 64-bit
TwinCAT XAE Shell.
The EL3201-0020 is the factory calibrated version of the EL3201-0010.
The EL3201-0020 analog input terminal facilitates the direct connection
of a resistance sensor. The measured resistance value can either be
output directly in ohms or transformed into a temperature.
If the temperature at the measuring point is of interest, the conversion
from resistance to temperature can be carried out in the terminal
according to various sensor characteristics (Pt100. Pt1000. NI120.
NI1000. KTY types, etc.). The EL3201-00x0 can operate sensors in
4-wire technology, external bridges must be set for the 2- and 3-wire
connection. This terminal must be operated using 4-wire technology
for maximum accuracy. The EtherCAT Terminals indicate their
measurement capability by means of light emitting diodes and status
bits in the EtherCAT process image.
The individual Beckhoff factory calibration certificate can be downloaded
here for each device. Recalibration (ZS9001) is possible via Beckhoff
Service.
The EL3182 analog input terminal for HART-capable field devices
supplies measuring transducers located in the field and transmits
their analog measuring signals electrically isolated to the
automation device. With a technical measuring range of 107% of
the nominal range, the terminal also supports commissioning with
sensor values in the limit range and the evaluation according to
NAMUR NE43.
SEW EURODRIVE MC07B0005-5A3-4-S0 |
SIEMENS 6ES7 313-1AD03-0AB0 |
NEWALL E70 DP8 DIGITAL SENDING UNIT E702LSO LATHE |
NEWALL DP8 DIGITAL SENDING UNIT 8SC211000 CSS |
MITUTOYO RS-232C 09CAA402 CODE OUT UNIT |
Baumuller BUS21-15/30-31-020 |
Allen-Bradley 1756-OF4 BOX NO OPEN |
Sick AFM60A-S4NB018X12 Absolute Encoder 1059039 |
Siemens 6AV6 542-0BB15-2AX0 6AV6542-0BB15-2AX0 |
Beckhoff ELM3504-0000 |
OMRON CP1H-XA40DT1-D |
SEW EURODRIVE MDS60A0022-5A3-4-00 With DIO11A |
ALLEN-BRADLEY 1785-L40C D REV.E01 |
ALLEN-BRADLEY 2801-NL4 SER A - NIKON HS-14 |
HONEYWELL R4348B1016 |
PICIORGROS FTR-700H/D2.24.485 |
EUCHNER GSBF05R16-502 |
BAUMULLER WEBER WUS21-15/30-31-030 |
UNITRONICS V350-35-T38 |
HONEYWELL FF-SPE44TXG |
PHILIPS PM 9873A/01 TC linearizer |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved