Brand: Honeywell
Model Number: 900G03-0202
Part Number: 900G03-0202
Type: Digital Input Module
Product Origin: USA
Payment: T/T, Western Union, Credit Card
Dimensions: 12.7 x 10.2 x 2.5 cm
Weight: 0.45 kg
Certificate: CE, UL
Warranty: 1 year
Analog Inputs
The UDC3500 has three universal analog inputs with a typical accuracy of ±0.10% of
full-scale input and a typical resolution of 16 bits.
These can be configured to act as one Universal and four High Level Inputs for a total of five analog inputs.
All analog inputs are sampled six times per second (every 166 ms).
The Process Variable input can be one of the various Thermocouple, RTD, Radiamatic or
linear actuations. Linear actuations have Thermocouple, RTD, and Radiamatic
transmitter characterization capability as a standard feature. Linear actuations also have square root capability.
The optional second and third inputs are isolated from each other and all other inputs and outputs and accept the same actuations as input one.
Input 3 provides the Slidewire input for Position Proportional control. These optional inputs can each be split into two high level inputs.
The fourth input is enabled by first configuring Input 2 as a 20 mA or 5 Vdc input type (high level) and moving a jumper on the Second Optional Input Board.
Input 4 will then be available as a high level input.
The fifth input is enabled by first configuring Input 3 as a 20 mA or 5 Vdc input type (high level) and moving a jumper on the Third Optional Input Board.
Input 5 will then be available as a high level input.
I/O Modules
The following I/O modules are available to create a custom control solution.
16 Channel Universal IO Module Galavanically isolated Input/Output to chassis (p.27)
8-point universal analog input modules: Galvanic isolation point to chassis inputs may be mixed on a module and may include multiple thermocouple types,
RTDs, ohms, voltage or mill voltage types – all easily assigned using the Process Control Designer configuration tool.
High point-to-point galvanic isolation simplifies installation and saves the expense of external isolation hardware (p.6).
16-point high level analog input module: each point is configurable for V or mA. Galvanically isolated point to
chassis. Galvanically isolated point to point (p.10). 250-ohm shunt resistors can be added per channel.
4-point galvanically isolated analog output module.
Galvanically isolated point to chassis supports from 0 to 20mA each (p.12).
8-point analog output, galvanically isolated in 2 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.13).
16-point analog output, galvanically isolated in 4 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.14).
16-point digital input modules: Contact closure type, DC Voltage, AC Voltage and AC/DC voltage types (p.15).
Galvanically isolated in groups of 8 channel to chassis
32-point digital input module: DC voltage. Galvanically isolated point to chassis. Galvanically isolated in 2
groups of 16 points (p.1915).
8-point AC or 16-point DC digital output modules (sinking type). Galvanically isolated point to chassis.
Galvanically isolated in 2 groups of 8 points (p.18).
32-point digital output: DC voltage (sourcing type).
Galvanically isolated point to chassis. Galvanically isolated in 2 groups of 16 points (p.23).
8-point relay output module: four form C type and four form A type relays.
Galvanically isolated point to chassis. Galvanically isolated relay to relay (p.20).
4 channel Pulse/Frequency/Quadrature I/O module.
Galvanically isolated point to chassis (p.24).
Alarms
Up to four electromechanical alarm relays are available to activate external equipment
when preset alarm setpoints are reached. Each of the four alarms can be set to monitor
two independent setpoints. Each alarm setpoint can be either high or low alarm. The
alarm type can be selected to be either of the inputs, the Process Variable, Deviation,
Output, Shed from communications, PV rate of change, or to alarm on manual mode
activation or a Current Output Open failure. It can also be used as an On or Off event at
the beginning or end of a Ramp/Soak segment. An individual alarm hysteresis setting is
provided for each relay and these are configurable from 0 to 100% of range.
Alarms can be configured as latching or non-latching. continued
Alarm blocking is also available which allows start-up without alarm energized
until after it first reaches the operating region.
PV rate of change alarm.
Loop break alarm.
Timer output reset.
Diagnostic Alarm
Other advantageous products on sale are listed below:
Honeywell Analog Input (8 channel)900A01-0202
Honeywell Analog Input Hi level (16ch)900A16-0101
Honeywell Analog Output 0 to 20mA (4 channel)900B01-0301
Honeywell Analog Outputs 0 to 20mA (8 channel 5 modules/rack)900B08-0101
Honeywell Analog Outputs 0 to 20mA (16 channel 2 modules per rack)900B16-0101
Honeywell Digital Input Contact type (16 channel)900G01-0202
Honeywell Digital Input 24VDC (16 channel)900G02-0202
Honeywell Digital Input 120/240 VAC (16 channel)900G03-0202
Honeywell Digital Input 120/240 VAC-125VDC (16 channel Isolated)900G04-0101
Honeywell Digital Input 24VDC (32 channel)900G32-0101
Honeywell Digital Output Relays ( 8 channel)900H01-0202
Honeywell Digital Output 24VDC (16 channel) 900H02-0202
Honeywell Digital Output 120/240 VAC (8 channel) 900H03-0202
Honeywell Digital Output 24VDC (32 channel)900H32-0101
Honeywell Pulse/Freq/Quad (4chan 1Quad)900K01-0201
Honeywell Low VoltageTerminal Block (Euro style) Note 3 900TEK-0101
Honeywell Low VoltageTerminal Block (Barrier Style) Note 3 900TBK-0101
Honeywell High VoltageTerminal Block (Euro style) Note 3 900TER-0101
Honeywell High Voltage Terminal Block (Barrier Style) Note 3 900TBR-0101
Honeywell VoltageTerminal Block (36 channel) Note 3 900TCK-0101
Honeywell Analog Input Remote Terminal Panel (RTP) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTA-L001
Honeywell Relay Output Remote Terminal Panel (RTP) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTR-H001
Honeywell DI DO AO 16pt AI Remote Terminal Panel (RTP) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTS-0001
Honeywell Low Voltage RTP Cable (1.0M 3.28ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-L110
Honeywell Low Voltage RTP Cable (2.5M 8.2ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-L125
Honeywell Low Votage RTP Cable (5.0M 16.4ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-L150
Honeywell High Voltage RTP Cable (1.0M 3.28ft.) Note 6 (NOT FOR SIL2 SYSTEMS) 900RTC-H110
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved