Manufacturer : Honeywell
Product No. : 900A16-0101
Product Type : Analog Input Module
Inputs per module : 8 (isolated)
Input types : mV, V, T/C, RTD, ohms, mA, slidewire assigned to any channel
Signal Source : Thermocouple with cold junction compensation.
RTD, PT100 3 wire, 40 ohms balanced maximum.
Thermocouples: 100 Ohms/Leg. 100 (except Low), 500 & 1000 RTD: 100 Ohms/Leg. 100 YIS: 100 Ohms/Leg. 100-Low RTD & 10 ohm Cu: 10 Ohms/Leg. Slidewire 100 to 6.500 Ohms: 10% of total res./leg.
Input Impedance : 10 megohms for T/C and mV inputs; >1 megohm for volts and 250 ohms for mA inputs.
Galvanic Input Isolation. 400 VDC point to point, 1K VDC to logic. RTDs are isolated in pairs (IRTD is common to two inputs).
Noise Rejection : Series Mode >60dB. Common Mode >130dB at 120VAC.
Over-range limit : +/- 10% for linear ranges (volts). +/-1% for non-linear ranges (T/C, RTD).
T/C Break Detection : Via current pulse
Shipping Weight : 2 Kg
Remote Terminal Panels
Optional DIN rail mounted Remote Terminal Panels (RTPs) are available for use with pre-wired cables to reduce installation time and labor expense.
Four types of RTPs are available: analog inputs, relay outputs, redundant I/O and other I/O modules.
Three cable lengths are also available to match hardware to installation variations.
Analog inputs RTPs include transmitter shunt resistors and transmitter power terminals with individual circuit fuses.
The Relay Output RTP includes a fuse and power disconnect switch for each output.
All the three types of RTP panels also switch power to allow module removal and installation under controller power.
Key Features
The 5701 Series Control System is part of the 57 System family and is designed to monitor and control field installed industrial gas detectors.
The key features of the system are as follows.
Provides up to 16 gas detection channels in a standard 19'' subrack using a 3U card format.
Provides up to 8 gas detection channels in a 3U card format in a half 19'' subrack.
Racks are available for both front and rear wiring.
Simple field connection for wires up to 2.5mm2.
Single channel operation mode for high integrity systems.
Other Modules
In addition to I/O, the following modules are available.
Scanner 1 module, single port (p.31)
Scanner 2 Module, dual port (p.32)
Universal AC Power Supply, 60W (p.4)
Power Supply 24VDC, 60W (p.4)
Redundant Switch Module (p.33)
Power Status Module (p.33)
I/O Modules
The following I/O modules are available to create a custom control solution.
16 Channel Universal IO Module Galavanically isolated Input/Output to chassis (p.27)
8-point universal analog input modules: Galvanic isolation point to chassis inputs may be mixed on a module and may include multiple thermocouple types,
RTDs, ohms, voltage or mill voltage types – all easily assigned using the Process Control Designer configuration tool.
High point-to-point galvanic isolation simplifies installation and saves the expense of external isolation hardware (p.6).
16-point high level analog input module: each point is configurable for V or mA. Galvanically isolated point to
chassis. Galvanically isolated point to point (p.10). 250-ohm shunt resistors can be added per channel.
4-point galvanically isolated analog output module.
Galvanically isolated point to chassis supports from 0 to 20mA each (p.12).
8-point analog output, galvanically isolated in 2 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.13).
16-point analog output, galvanically isolated in 4 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.14).
16-point digital input modules: Contact closure type, DC Voltage, AC Voltage and AC/DC voltage types (p.15).
Galvanically isolated in groups of 8 channel to chassis
32-point digital input module: DC voltage. Galvanically isolated point to chassis. Galvanically isolated in 2
groups of 16 points (p.1915).
8-point AC or 16-point DC digital output modules (sinking type). Galvanically isolated point to chassis.
Galvanically isolated in 2 groups of 8 points (p.18).
32-point digital output: DC voltage (sourcing type).
Galvanically isolated point to chassis. Galvanically isolated in 2 groups of 16 points (p.23).
8-point relay output module: four form C type and four form A type relays.
Galvanically isolated point to chassis. Galvanically isolated relay to relay (p.20).
4 channel Pulse/Frequency/Quadrature I/O module.
Galvanically isolated point to chassis (p.24).
Other advantageous products on sale are listed below:
Honeywell 900R04-0200 4 I/O Slot Rack |
Honeywell 900R08-0200 8 I/O Slot Rack |
Honeywell 900R12-0200 12 I/O Slot Rack |
Honeywell 900R08R-0200 8 Slot Rack -Red. Power |
Honeywell 900R12R-0200 12 Slot Rack Red. Power |
Honeywell 900PSM-0101 Redundant Power Status Module |
Honeywell 900S75-0360-00 I/O Scanner 2 Port (1 per I/O rack) |
Honeywell 900S50-0360-00 I/O Scanner (for remote rack) |
Honeywell 900P01-0101 P01 Power Supplies 120/240VAC 60W |
Honeywell 900P02-0101 P02 Power Supplies 120/240VAC 28W |
Honeywell 900P24-0101 24Vdc 60W Power Supplies |
Honeywell 900C70-0360-00 Controller C70 CPU |
Honeywell 900C50-0360-00 Controller C50 CPU |
Honeywell 900C30-0360-00 Controller C30 CPU |
Honeywell 900C75-0360-00 Redundant Controller C75 CPU |
Honeywell 900RSM-0101 Redundant Switch Module |
Honeywell 900C70S-0360-00 Controller C70 CPU SIL |
Honeywell Controller C50 CPU SIL900C50S-0360-00 |
Honeywell Controller C30 CPU SIL 900C30S-0360-00 |
Honeywell Redundant Controller C75 CPU-SIL 900C75S-0360-00 |
Honeywell Redundant Switch Module 900RSM-0101 |
Honeywell I/O Scanner 900S75S-0360-00 |
Honeywell I/O Scanner 900S50S-0360-00 |
Honeywell 120/240VAC 60W 900P01-0201 |
Honeywell 120/240VAC 28W 900P02-0201 |
Honeywell I/O Card Selections |
Honeywell Analog Input (8 channel)900A01-0202 |
Honeywell Analog Input Hi level (16ch)900A16-0101 |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved