System boundaries
The life cycle assessment covers all environmental aspects for extraction
and production of raw materials, manufacturing of main parts, assembly of
the switch, transportation and the use of the product, dismantling, fragmentation and disposal after end of life.
It includes consumption of material and energy resources as well as emissions and waste generation.
The recycling of scrap is not included in the calculations.
Functional unit
The functional unit is defined as A of rated operational current AC21.
OT25 25 A
OT45 45 A
OT125 125 A
The SD (Symphony DIN) Series is a green portfolio of completely scalable control
and I/O products that work in any environment or geographic location,
Through seamless interconnections with smart field and electrical devices and higher level applications,
these rugged control and I/O products deliver lower energy consumption,
an extreme operating temperature range, and a scalable architecture in a compact, modular footprint,
making SD Series the best automation solution for your new installation, upgrade or expansion.
Powerful, scalable controller family for high-end (SPC800/HPC800), mid-range (SPC700)
and small (SPC600/SPC700) applications from discrete and continuous,
to batch and advanced control applications.
Simultaneous support for SD Series, HR Series and S800 I/O subsystems.
SD Series controllers communicate with S+ Operations, S+ Engineering and other higher level applications via a high-speed,
high-throughput, and high-security Fast Ethernet-based redundant plant network.
Allocation unit
The factor for allocation of common environmental aspects (such as
manufacturing energy) during manufacturing is calculated as used working
cost in relation to the total annual production volume for the manufacturing.
Low Voltage Products unit is a part of the Business Unit ATLV, Automation Technology Low Voltage.
Low Voltage Products develops, manufactures and markets a comprehensive range of low voltage
products and the most extensive assortment of low voltage systems in the market.
Our customers include industry, panel builders, machine and equipment manufacturers, electrical contractors and electrical power plants.
Environmental management
OT-switches are manufactured at the Finish plant,
which has been certified according to ISO 14001 since 1997
(the plant has been also certified according to the ISO 9001 quality management standard since 1993).
Life cycle assessment is applied continuously to all product development.
The HBR01-CJC the mounting base is for RAI04, Redundant, 16-CH, TC & mV analog input modules.
The base includes a built-in RTD that can be used for Cold Junction Compensation.
Two (2) 16-point headers on the base provide connections to either (2) pluggable
16-point terminal blocks for direct connection of field signal wires or to SPK0x_-yy marshaling
cables when field signal wires are landed on 3rd party termination hardware.
The calculations are based upon an estimated life-time of 10 years when
operating 3650 hours per year (10 hours per day, 365 days, load factor
70%). Energy during use is calculated from power loss. An European mix
of energy has been used for calculating energy consumption during
manufacturing, use and disposal.
This environmental product declaration is based on a life cycle assessment
LCA. It has been conducted according to ISO 14040-43 series, with the
EcoLab software from Nordic Port AB, Gothenburg, Sweden.
The data and calculations are based on LCA.
Here are the baselines for the LCA calculation:
Features and benefits
Termination for up to sixteen (16) analog I/O process signals within a horizontal row.
All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are 100% fully compatible with each other.
Thus, Singular & Redundant, Compact or Full-size I/O modules can be mounted within a single, common HN800 I/O bus.
Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module type.
Latching device on the base locks the base into position on DIN-Rail.
Industry standard 35-mm DIN rail, Horizontal row mounting.
You may need the following additional products:
ABB DO02 DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DO02A DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DRMP-19 DIN-Rail Mtg Panel 19 inch Generic HW |
ABB DRMP-19SD DIN-Rail Mtg Panel 19 inch SD Series |
ABB HAI805 Analog Input Module 8-CH HART |
ABB HAI805A Analog Input Module 8-CH HART |
ABB HAO805 Analog Output Module 8-CH HART |
ABB HAO805A Analog Output Module 8-CH HART |
ABB HBS01-CJC Horiz. Base Single Cold Junction Comp. |
ABB HBS01-CJCA Horiz. Base Single Cold Junction Comp. |
ABB HBS01-EPD Horiz. Base Single Ext. Pwr Inputs |
ABB HBS01-EPDA Horiz. Base Single Ext. Pwr Inputs |
ABB HBS01-FPH Horiz. Base Single Field Pwr Hot |
ABB HBS01-FPHA Horiz. Base Single Field Pwr Hot |
ABB HBS01-FPN Horiz. Base Single Field Pwr Neutral |
ABB HBS01-FPNA Horiz. Base Single Field Pwr Neutral |
ABB HBX01K02 HN800 Bus Extender Kit Horizontal |
ABB HBX01K02A HN800 Bus Extender Kit Horizontal |
ABB HBX01L HN800 Bus Extender Horizontal Left |
ABB HBX01LA HN800 Bus Extender Horizontal Left |
ABB HBX01R HN800 Bus Extender Horizontal Right |
ABB HBX01RA HN800 Bus Extender Horizontal Right |
ABB ITU805 HART I/O Module Mounting Base |
ABB ITU805A HART I/O Module Mounting Base |
ABB PI01 Pulse/Frequency Input module 8-CH |
ABB PI01A Pulse/Frequency Input module 8-CH |
ABB SPK01B-02 I/O Cable Bottom Flying Leads 2.0 M |
ABB SPK01B-03 I/O Cable Bottom Flying Leads 3.0 M |
ABB SPK01B-04 I/O Cable Bottom Flying Leads 4.0 M |
ABB SPK01B-05 I/O Cable Bottom Flying Leads 5.0 M |
ABB SPK01B-06 I/O Cable Bottom Flying Leads 6.0 M |
ABB SPK01B-10 I/O Cable Bottom Flying Leads 10.0 M |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved