The VBR01-CJC the mounting base is for Redundant RAI04 (16-CH) TC & mV Analog Input module.
The base includes a built-in RTD that can be used for Cold Junction Compensation.
Two (2) 16-point headers on the base provide connections to either (2) pluggable 16-point terminal blocks
for direct connection of field signal wires or to SPK0x_-yy marshaling cables when field signal wires are landed on 3rd party termination hardware.
Features and benefits
• Termination for up to sixteen (16) TC / mV process signals within a Vertical column.
• All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are 100% fully compatible with each other.
Thus, Singular & Redundant, Compact or Full-size I/O modules can be mounted within a single, common HN800 I/O bus.
• Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module type.
• Latching device on the base locks the base into position on DIN-Rail.
• Industry standard 35-mm DIN rail, Vertical Column mounting.
Symphony Plus Control & I/O BRC410
ƒ Performance increase depends on specific
function blocks used, but in general
performance of latest module (BRC410)
compared with older modules:
ƒ ~ 10x vs. MFP01/02/11/12
ƒ ~ 4x vs. BRC100/200
ƒ Enhanced On-Line Configuration provided
by BRC410
ƒ BRC410 also provides ModBus TCP
ƒ BRC410 support 30,000 block addresses
and 4,000 Modbus TCP/IP points
ƒ Infi90 Modulebus support*
ƒ Downloadable firmware
I/O SYSTEMS - SD SERIES I/O DO05
The DO05 digital output module provides16, CH-2-CH isolated electromechanical relay contact outputs.
The electromechanical relay contacts are capable of handling up to 3.0 A.
The module executes at 1 msec cycle and has an average response time of 0.5 msec based on when command is received from controller.
The DO05 module provides staple jumpers to select between NO or NC contacts.
FC 221 (I/O Device Definition) sets DO module operating parameters and each output channel is configured
using FC 225 (Digital Output CH) to set indivdual output channel parameters such as alarm state setting,
default state on loss of communication with controller, etc.
processor load
• Optical communication
• Industrial grade hardware with no moving parts
• Long life cycle, easy upgrading
• Robust reliance file system, insusceptible post power loss
07EA90-SI ABB modules are used to convert analog signals to digital signals and transmit them to the control system for monitoring and controlling industrial processes.
These accuracy settings are only used when negotiating for time mastership with
other nodes in the underlying Harmony control network.
Message Wait Period
Message wait period is the Period that Harmony Server waits before attempting to
assume time mastership on the control network. This property is used only when
Time Synchronization is enabled. The permissible values are between 180 and 3660
seconds. Additionally, the configured value must greater than the Master Update Period.
You may need the following additional products:
ABB AO01A AO module 16-CH High Level |
ABB AO02 AO module 16-CH with HART |
ABB AO02A AO module 16-CH with HART |
ABB AO05 AO Module 8-CH Galv. isol. HART |
ABB AO05A AO Module 8-CH Galv. isol. HART |
ABB BK01 Blank SD I/O Module Cover |
ABB DI01 DI module 16-CH 24 / 48 VDC SOE |
ABB DI01A DI module 16-CH 24 / 48 VDC SOE |
ABB DI02 DI02 16-CH 120 VAC / 125 VDC SOE |
ABB DI02A DI02A 16-CH 120 VAC / 125 VDC SOE |
ABB DI03 DI module 16-CH 24 VDC |
ABB DI03A DI module 16-CH 24 VDC |
ABB DI04 DI module 16-CH 48 VDC |
ABB DI04A DI module 16-CH 48 VDC |
ABB DO01 DO module 16-CH 24 / 48 VDC max 250mA |
ABB DO01A DO module 16-CH 24 / 48 VDC max 250mA |
ABB DO02 DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DO02A DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DRMP-19 DIN-Rail Mtg Panel 19 inch Generic HW |
ABB DRMP-19SD DIN-Rail Mtg Panel 19 inch SD Series |
ABB HAI805 Analog Input Module 8-CH HART |
ABB HAI805A Analog Input Module 8-CH HART |
ABB HAO805 Analog Output Module 8-CH HART |
ABB HAO805A Analog Output Module 8-CH HART |
ABB HBS01-CJC Horiz. Base Single Cold Junction Comp. |
ABB HBS01-CJCA Horiz. Base Single Cold Junction Comp. |
ABB HBS01-EPD Horiz. Base Single Ext. Pwr Inputs |
ABB HBS01-EPDA Horiz. Base Single Ext. Pwr Inputs |
ABB HBS01-FPH Horiz. Base Single Field Pwr Hot |
ABB HBS01-FPHA Horiz. Base Single Field Pwr Hot |
ABB HBS01-FPN Horiz. Base Single Field Pwr Neutral |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved