Bus Monitoring Module Manufacturers ABB, Bailey Model(s)
ABB Bailey Infi 90, ABB Bailey Infi 90 and Net 90
Additional Information Bus Monitoring Module for use with IEPEP03, IEPEP04 and NPEP05.
Estimated Shipping Size Dimensions: 7.0" x 2.0" x 10.0" (17.8 cm x 5.1 cm x 25.4 cm)
Weight: 0 lbs 9.0 oz (0.3kg )
Tariff Code: 8504409540
Country of Origin: United States Ships from Webster NY, USA
Bus Monitoring Module
The Harmony OPC server provides OPC
connectivity between devices on the INFI-Net
control network and OPC client applications. In
non-redundant and redundant configurations,
it can be used in conjunction with ABB products
such as DataLink and popular non-ABB products
such as OSIsoft PI System and Aspen InfoPlus.21.
HR Series ICI800 Ethernet CIU provides Ethernetbased communication between INFI-Net and
the system’s engineering tools, HMI and the
Harmony OPC server for connection to thirdparty applications. As per NERC CIP-007-2
R5, SSL certifications authenticate its
connections with interface applications, further
safeguarding the integrity and privacy of the
ICI800 communication path.
Applications
The binary input board 23BE40 performs the following processing functions for different types of signals:
Digital filtering to suppress contact jumping
Suppression of technically induced chattering signals
Intermediate position suppression and double indication monitoring
Consistency check of all binary input channels assigned to digital measurement values
The 23BE40 has a buffer for temporarily storing 50 time-stamped event messages in chronological order, designated for transmission to the communication unit.
The board's microcontroller handles all time-critical tasks for the parameterized processing functions.
In addition, it communicates interactively with the RTU560 system bus.
All configuration data and processing parameters are transmitted via the RTU560 system bus.
All configuration data and processing parameters are loaded from the communication unit via the RTU560 bus.
The board is equipped with a serial interface to the RTU560 system bus.
During initialization and operation, the board performs a series of tests. If a fault occurs, it is reported to the communication unit.
All fault conditions affecting the board's functionality are indicated as general fault signals by means of light emitting diodes (ST).
Faults in the board are detected by the communication unit.