The easYgen-3500XT is available in two packages. P1. focused at complex paralleling applications provides
redundant Ethernet communication, LS-5 connectivity, and standard I/O set, while P2. Co-Gen/CHP model
offers expanded onboard I/O set, 3-ph busbar voltage measurement capability and phase rotation monitoring
between gen-busbar and busbar-utility. These packages are available without a display in a rugged metal hous
ing suitable for back panel installations (easYgen-3400XT-P1 and easYgen-3400XT-P2 respectively). A sophis
ticated touch screen remote panel (RP-3000XT) complements them as an operator control panel.
A version of easYgen-3500XT (easYgen-3500XT-P1-LT and easYgen-3500XT-P2-LT) is designed to operate
down to -400 C for outdoor applications.
The MicroNet Plus Expansion Chassis may use either single or redundant power supplies.
Each power supply module produces three regulated outputs:
24 V @ 12 A (max), 5 V @ 32 A (max, derated above
55 degree C external ambient temperature), and 5 V Precharge @ 3 A (max).
A motherboard located on the back of the chassis provides the
interconnection of the three outputs from each power supply module
into three corresponding power busses: 24 V bus, 5 V bus, and 5 V precharge bus.
The 24 V and 5 V busses are load shared between the two power supply modules.
The 5 V precharge bus is not load shared.
Power requirements depend on the number and type of modules supplied for each system. For a system
with a single I/O chassis, size the input power source according to the rating of the MicroNet Plus power
supply to which the source is connected. Do not size the supply mains for the sum of the MicroNet Plus
power supply ratings when redundant supplies are used. MicroNet Plus supplies are redundant when
installed in the same chassis. Redundant supplies share the load between them equally, but each must
provide for full load in the event that one of the units is disabled. Table 4-3 gives the maximum overload
protection for supply mains connected to any single or redundant pair of MicroNet Plus main power
supplies. It is not recommended that both MicroNet Plus main power supplies of a redundant pair be
connected to a single source, since failure of that source would disable the system.
Woodward | 8273-1013 | 2301E-ST – Steam Turbine Control 8273-1013 | |||
Woodward | 8273-1014 | 2301E-ST – Steam Turbine Control, Hazardous Location Zone 2 8273-1014 | |||
Woodward | 8237-2046 | 2301E-HT – Hydro Turbine Control (Francis), 24 VDC, Ordinary Location 8237-2046 | |||
Woodward | 8200-1400 | 505HT – LVDC, Pelton Turbines 8200-1400 | |||
Woodward | 8200-1401 | 505HT – HVAC/DC, Pelton Turbines 8200-1401 | |||
Woodward | 8200-1402 | 505HT – LVDC, Francis / Kaplan Turbines 8200-1402 | |||
Woodward | 8200-1403 | 505HT – HVAC/DC, Francis / Kaplan Turbines 8200-1403 | |||
Woodward | 8269-1073 | 17” TouchPanel OCP – Includes RemoteView Software Program 8269-1073 | |||
Woodward | 8928-5311 | RemoteView - Software License 8928-5311 | |||
Woodward | 5404-1801 | Old 505 to New 505 Retrofit Wiring Kit 5404-1801 | |||
Woodward | 8200-1500 | Peak200 – Bulkhead Mount, LV 8200-1500 | |||
Woodward | 8200-1501 | Peak200 – Bulkhead Mount, HV 8200-1501 | |||
Woodward | 8200-1502 | Peak200 – Bulkhead Mount, LV, ATEX Zone 2 8200-1502 | |||
Woodward | 8200-1503 | Peak200 – Front Panel Mount, LV 8200-1503 | |||
Woodward | 8200-1504 | Peak200 – Front Panel Mount, HV 8200-1504 | |||
Woodward | 8200-1505 | Peak200 – Front Panel Mount, LV, ATEX Zone 2 8200-1505 | |||
Woodward | 8200-1508 | Peak200 – Bulkhead Mount, HV, Class1 Div2 Haz. Loc. Compliant 8200-1508 |