Graphs and Figures
This graphical reference section includes additional information about the 3500 System.
3500 System Example
1. Power Supplies: This particular rack has an AC-powered supply in the primary (lower) position, and a DC-powered backup supply in the upper position.
2. Keylock security prevents tampering with the configuration of the monitors in the rack.
3. Transient Data Interface (TDI): Provides an interface to configuration software and to System 1 Condition Monitoring &Diagnostic software.
It also coordinates communication between all modules in the rack.
4. Keyphasor Module: Accepts single and multi-event per-rotation signals from proximity probes and magnetic pickups installed on rotating equipment.
5. 3500/72M (Recip Rod Position) and 3500/77M (Recip Cylinder Pressure) monitors are used for condition monitoring of reciprocating compressors.
6. 60/61 Temperature Monitors.
7. 3500/42M Proximitor/Seismic vibration monitors.
8. Buffered transducer signals are provided for use with portable test instruments.
9. Unused slots are protected with “Future Expansion” covers, and are available for use with additional modules.
10. 3500/33 16-Channel Relay Module.
11. 3500/92 Modbus® Communication Gateway.
12. Standard rack for 19” EIA rail mounting
Hot Insertion
All Monitors and Power Supplies (when redundant supplies are used) can be removed or inserted when the rack is under power.
This facilitates easier maintenance and system expansion without interruption of machinery protection functions or system operation.
Time Synchronization
The system’s real-time clock can be synchronized with external clocks, via the Communication Gateway or via
connected Bently Nevada software.
The 3500 System’s alarm and event lists then provide time/date stamps that are synchronized with alarms
and events in other process and automation equipment.
This reduces or eliminates the need for elaborate, hardwired “Sequence of Event” recorders.
API 670 Compliance When configured properly, supplied with the correct number of relay modules, and provided with an
appropriate optional display, the 3500 System complies with the latest edition of the
American Petroleum Institute (API) Standard 670 for Machinery Protection Systems, for shaft-relative vibration, axial position,
temperature, reciprocating compressor rod drop, and casing vibration.
Alarm/Event Lists
Extensive alarm and event lists retain the 2000 most recent alarm events and 1000 most recent system
events (configuration changes, errors, etc.).
The system’s TDI retains the lists, which provide a description of each alarm or event and a corresponding date/time stamp.
These lists are available to the 3500/94M VGA Display module and also to the Communication Gateway module for export to process
control, historian, or other plant systems.
Display Options
Displays can range from local units mounted directly on the rack’s front panel,
to remote displays, to completely blind monitoring systems with an as-needed HMI (Human Machine Interface) connection for configuration and information.
Multiple displays can be connected concurrently without degrading system performance or interrupting basic machinery protection functions.
See Graphs and Figures for more information on VGA Touch Screen display options.
Other advantageous products on sale are listed below:
BENTLY | 3500-05-01-02-00-00-01 | System Racks |
BENTLY | 350005-01-03-00-00-00 | Rack Modules |
BENTLY | 3500-05-02-04-00-00-00 | DC Input Card Input Modules |
BENTLY | 3500-15 | Mechanical Protection Systems AC Power Modules |
BENTLY | 350015 127610-01 | AC Power Modules |
BENTLY | 350015 106M1079-01 | Universal AC Power Modules |
BENTLY | 350015 106M1081-01 | Universal AC Power Input Modules |
BENTLY | 3500-15 127610-01 | AC/DC Power Supplies Relay Modules |
BENTLY | 350015 133292-01 | Low Voltage DC Power Modules |
BENTLY | 350020 | Rack Interface Modules |
BENTLY | 3500-20 125744-02 | Standard Rack Interface Module |
BENTLY | 350020 125768-01 | Rim I/O Modules with RS232/RS422 Interface |
BENTLY | 350022M | Data Interface Module |
BENTLY | 350022M 138607-01 | Standard Transient Data Interface Module with USB Cable |
BENTLY | 350022M 146031-01 | Transient Data Interface I/O Module |
BENTLY | 350022M 288055-01 | Standard Transient Data Interface Module |
BENTLY | 350025 | Enhanced Keying Module |
BENTLY | 3500-25 149369-01 | Enhanced Keying Module |
BENTLY | 350025 184684-01 | Enhanced Keying Module |
BENTLY | 350025 149369-01 | Enhanced Key Phasor Module Dual Channel Module |
BENTLY | 350032 | 4-Channel Relay Module |
BENTLY | 350032 125712-01 | 4 Channel Relay Module |
BENTLY | 350032M | 4 Channel Relay Module Full Height Module |
BENTLY | 350033 149986-01 | Spare 16-Channel Relay Control Module |
BENTLY | 350040M | Proximity Monitor I/O Module |
BENTLY | 350040M 140734-01 | Proximity Monitor I/O Module |
BENTLY | 350040M 176449-01 | Proximity Monitor Module |
BENTLY | 3500-42M 176449-02 | Proximity/Seismic Monitor |
BENTLY | 350044M 176449-03 | Aerospace Derived GT Vibration Monitor |
BENTLY | 3500-45 | Position Monitor |
BENTLY | 350053 | Electronic Speed Detection Systems |
BENTLY | 3500-53 133388-01 | Overspeed Detection Module |
BENTLY | 350060 | Temperature MonitorSix temperature monitoring channels |
BENTLY | 3500-60 163179-01 | Sensor proximity power module |
BENTLY | 350092 | Communication Gateway Module |
BENTLY | 350092 136180-01 | Gateway Ethernet and Communication Module |
BENTLY | 60M100-00 | Detector Module |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved