Software Modules
MLink contains different software modules depending on its initial configuration. The software
modules are available on request.
Following software modules are available:
· Web Server
· OPC Server (DA & AE)
· Fieldbus
· Time Synchronization
· Redundant Operation
If a specific module is not available on the MLink, please contact your local ABB LVS Sales
organization should this be required.
Web Server
A Web Server can be activated inside MLink. Through network connection web interface
information can be displayed on MView or a PC using web browser software. For details about
Web Interface see the document:
MNS iS Interface Manual Web Interface.
OPC Server
With MNS iS an OPC Server (DA & AE) is available. The software is typically installed on a
server as part of the automation control system. The software installation program is delivered
separately. If activated, the MLink functions as a data provider for the MNS iS OPC Server. For
details about OPC Server see the document:
MNS iS Interface Manual OPC Server.
Fieldbus
MLink can include Fieldbus communication to DCS. The type of Fieldbus must be selected
before ordering the MLink type. The Fieldbus specific information (PROFIBUS, MODBUS etc.)
can be found in the following documents:
MNS iS Interface Manual Profibus
MNS iS Interface Manual Modbus
MNS iS Interface Manual Profinet IO
The EL operating mechanism of the Advac circuit breakers (in all versions) is fitted with a mechanical anti-pumping
device which prevents re-closing due to either electrical or mechanical commands.
Should both the closing command and any one of the opening commands (local or remote) be active at the same time,
there would be a continuous succession of opening and closing operations.
The anti-pumping device avoids this situation, ensuring that each closing operation is only followed
by a single opening operation and that there is no closing operation after this.
To obtain a further closing operation, the closing command must be released and then re-launched.
Furthermore, the anti-pumping device only allows circuit-breaker closure if the following conditions
are present at the same time:
1. Closing spring fully charged
2. Opening mechanical pushbutton and/or opening release coils (-MO1/-MO2) are not active.
3. The circuit breaker is in the Open position.
MNS iS
1TGC910211 M0201 MNS iS Interface Manual MLink, Release 7.0
1TGC910111 M0201 MNS iS MLink Upgrade Kit Manual
1TGC910221 M0201 MNS iS Interface Manual Web Interface, Release 7.0
1TGC910241 M0201 MNS iS Interface Manual Profibus, Release 7.0
1TGC910251 M0201 MNS iS Interface Manual Modbus, Release 7.0
1TGC910291 M0201 MNS iS Interface Manual PROFINET IO, Release 7.0
1TGC910281 M0201 MNS iS MControl Interface Manual Profibus Direct, Release 7.0
1TGC910261 M0201 MNS iS Interface Manual Redundancy, Release 7.0
1TGC910271 M0201 MNS iS MConnect Interface Manual, Release 7.0
1TGC910001 B0204 MNS iS System Guide
1TGC910201 M0201 MNS iS Quick Guide Installation and System Setup, Release 7.0
1TGC910090 M0201 MNavigate Help file V7.0
1TGC910018 M0208 MNS iS ATEX – Enhancements for Safety
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved