Connect Ground Bus to Grounding-Electrode System
The grounding-electrode system is at earth-ground potential and is the central ground for all electrical equipment and ac power within any facility.
Use a grounding-electrode conductor to connect the ground bus to the grounding-electrode system.
Use at minimum 8.3 mm2 (8 AWG) copper wire for the grounding-electrode conductor to guard against EMI.
The National Electrical Code specifies safety requirements for the grounding-electrode conductor.
Features and Benefits
Select I/O modules to exactly match your application. Combination
modules allow you to have inputs and outputs in a single slot for
efficient use of your chassis space.
Expand the I/O capacity of your fixed controller system. Two discrete
I/O modules can be added to the fixed controller’s 2-slot expansion
chassis increasing the flexibility of the system.
All relay contacts are Silver Cadmium with Gold overlay. Gold plating
resists oxidation and tarnishing resulting from non-use. Silver
Cadmium acts as an excellent conductor.
High-density 32-Point DC I/O and fast response DC inputs are available.
These modules allow you to apply the SLC 500 processors in a
broader spectrum of control applications.
Open-circuit Detection (Bit 12)
The module tests all enabled channels for an open-circuit condition
each time it scans its inputs. Possible causes of an open-circuit
include:
• broken thermocouple or CJC thermistor.
• thermocouple or CJC thermistor wire cut or disconnected.
• Usare una treccia in rame da 2.54 cm o un filo in rame da 5.2 mm2 (10 AWG) per collegare i singoli
chassis, la custodia ed un bus di terra centrale montato sul pannello posteriore
• Usare una custodia in acciaio per evitare disturbi elettromagnetici (EMI)
• Assicurarsi che il visore posto sullo sportello della custodia sia uno schermo laminato o un substrato
ottico conduttivo (per bloccare gli EMI)
• Installare un cavo di massa per il contatto elettrico tra lo sportello e la custodia; non utilizzare la
Contacting Rockwell Automation
If you need to contact Rockwell Automation for assistance, please have the following information available when you call:
• A clear statement of the problem including a description of what the system is doing, LED indicator status, and bit status of I/O image words (channel configuration and status) for the module
• Fault code if the SLC processor is faulted
• Processor type and firmware (FRN) number from label on processor
• A list of things you have already tried to remedy the problem
• Hardware types in the system including I/O modules and chassis
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved