Controlinc Network Master Model M250N contains redundant valve actuator network masters
in a single enclosure. M250N supports one Controlinc E>Net ring network with up to 250 valve
actuators. Options for support of redundant bus networks and redundant E>Net rings are also
available. The supplied system uses standard RS485 and Modbus RTU protocol for the valve
actuator networks. Ethernet TCP/IP encapsulated Modbus protocol connections are provided
for redundant host computer networks. The Ethernet links are IEEE 802.3 with RJ45 connectors
for 10/100Base-TX. Protocol is Ethernet v2 encapsulation TCP/IP Version 4.

Redundant systems consist of two identical chassis with identical software. One is the
primary master and the other a hot stand-by master. The two chassis may switch roles of
primary and hot stand-by at any time. Figure 1 shows the specific system configuration of
the supplied system. The network masters communicate with Controlinc valve actuators
that control both block valves (Open, Stop, Close) and modulating or positioner type valves.
Each chassis consists of two Modbus Slave modules located in Slots 3 and 4. These slave
modules communicate with redundant Modbus host systems up line. The CoProcessor
installed in Slot 1 is the Controlinc Network Master to a ring field network. Two ports of the
Network Master module are connected to Network Interface Module (NIM) Model M124I
with redundant, isolated ports. Each NIM has connections to the redundant Network Master
modules of the redundant chassis. Any one of the four ports may acquire data from and
control all actuators in the field in either direction around the network. Multiple M250N
systems may be networked from a single host or redundant hosts to automate any size
system from a few valves to thousands of valves covering a large network area. Ten (10)
independent processors ensure full redundancy of all functions in a single unit.
The enclosure is rated for NAMA 4/12 and IP65/IP55. Dimensions of the enclosure are shown
in Figure 5. Mounting dimensions are shown in Figure 6. The enclosure may be bulkhead
mounted using the internal mounting holes. External mounting brackets may be used if
desired. When mounting using the internal mounting holes, caution must be used to ensure
the holes are sealed to maintain the NEMA/IP rating. The enclosure is supplied with five 1/2 in.
compression type cable entry hubs. These may be fitted with conduit type fittings if desired.
If the system includes backup LCD keypad terminal, some planning is required to allow for
proper height above the floor to view the display and properly operate the keypad.

Woodhead 1301110023 INPRO-YELLOWIN STRINGLIGHT 100'W/TEMP LIGHT CABLE 10 Sockets
AGXGOLF BOY'S XS 5 WOOD HEAD COVERS: GRAPHITE SHAFT, AVAILABLE IN ALL LENGTHS
WOODHEAD DND02A-M040 1300270016 5P MALE/MICRO PIGTAIL STRAIGHT CORD SET
WOODHEAD 703000B01F200 MICRO-CHANGE CORDSET 3P 20' IN PACKAGE
WOODHEAD INDUSTRIES 583030A10M040 / 583030A10M040
WoodHead 804006H09M030 Molex 1200658730 Molded Sensor Cable NiBag
Emerson SE4303T03 RTD Input CHARM
Emerson SE4303T02 Thermocouple/mV Input CHARM
Emerson SE4303T01 Analog Input 4-20 mA HART CHARM
Emerson SE4301T02 Discrete Input 24VDC Low-Side sense (dry contact) CHARM
EPRO MMS6120 9100-00002C-08 Dual Channel Temperature Monitor
EPRO MMS6120 9100-00002-10 Dual Channel Temperature Monitor
EPRO CON011 9200-00001N Eddy Current Signal Converter
EPRO MMS6823 9100-00001-05 Displacement Monitor Module
EPRO PR6423/010-000-CN Eddy Current Sensor
EPRO PR6423/001-000 Eddy Current Sensor
EPRO PR6424/014-040 Eddy Current Sensor
EPRO PR6424/013-130+CON021 Eddy Current Sensor
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved