CET 10 Contronic Module Manufacturers ABB, Hartmann & Braun Model(s)
ABB H&B Contronic Additional Information H&B Contronic XX02 Module
Estimated Shipping Size Dimensions: 7.0" x 1.0" x 11.0" (17.8 cm x 2.5 cm x 27.9 cm)
Weight: 0 lbs 10.1 oz (0.3kg ) CET 10
Features and benefits
Termination for up to eight (8) analog I/O process signals within a horizontal row.
All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are
100% fully compatible with each other. Thus, Singular & Redundant, Compact or Full-size I/O
modules can be mounted within a single, common HN800 I/O bus.
Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module type.
Latching device on the base locks the base into position on DIN-Rail.
Industry standard 35-mm DIN rail, Horizontal row mounting.
Functional characteristics
Input and output interfaces: Equipped with rich input and output interfaces, including digital input and output,
analogue input and output, etc., it can be flexibly configured with different I/O modules to meet the signal acquisition
and equipment control requirements of various industrial sites. It can connect all kinds of sensors, buttons,
switches and other input devices, as well as motors, valves, relays and other output devices to achieve
comprehensive monitoring and precise control of industrial sites.
Expandability: support for expansion modules, the user can be based on the actual application scenarios and control requirements,
the flexibility to increase the number of I / O points, communication interfaces, special function modules, etc.,
to expand the system's functionality and scale, so that it can better adapt to the ever-changing production processes and control needs,
improve the flexibility and expandability of the system.
• The operator panel is designed for stationary installation on a planar surface, where the following conditions are fulfilled:
– no high explosive risks
– no strong magnetic fields
– no direct sunlight
– no large, sudden temperature changes
• Install the operator panel according to the accompanying installation instructions.
• Ground the operator panel according to the accompanying installation instructions.
• Only qualified personnel may install the operator panel.
• Separate the high voltage, signal and supply cables.
• Make sure that the voltage and polarity of the power source is correct before connecting the operator panel to the power outlet.
• Peripheral equipment must be appropriate for the application and location.
• In a Zone 2 environment, this equipment shall be installed in an enclosure that provides a degree of protection not less
than IP 54 or greater than IP 65 in accordance with IEC/EN 600079-0. The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.
• In a Zone 22 environment, this equipment shall be installed in an enclosure that provides a degree of
protection not less than IP 64 or greater than IP 65 in accordance with IEC/EN 600079-0.
The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.