The TMR5200 Module is designed for 3-2-0 operation. A TMR system cannot operate with a single CPU.
This module was designed and rated for –40 to +85 °C operation in the industrial marketplace.
RTN Port
In a TMR5200 based system, each Kernel CPU provides Real Time Network (RTN) capability for
expanding to other racks using Ethernet port 4 (RJ45). This RTN port communicates between the main
chassis CPU's and any Remote RTN modules located in an expansion chassis. The GAP software
application defines the expansion racks, their I/O modules, and the use of the RTN port (GAP block is RTN).
protection for supply mains connected to any single or redundant pair of MicroNet Plus main power
supplies. It is not recommended that both MicroNet Plus main power supplies of a redundant pair be
connected to a single source, since failure of that source would disable the system.
Multiple chassis systems using MicroNet Plus power supplies may have power supplies of the same
model, but in different chassis, connected to the same source. In this case, each branch to a chassis
must have its own overcurrent protection sized according to Table 4-3. and the power source must be
sized for the sum of the branches.
Power requirements depend on the number and type of modules supplied for each system. For a system
with a single I/O chassis, size the input power source according to the rating of the MicroNet Plus power
supply to which the source is connected. Do not size the supply mains for the sum of the MicroNet Plus
power supply ratings when redundant supplies are used. MicroNet Plus supplies are redundant when
installed in the same chassis. Redundant supplies share the load between them equally, but each must
provide for full load in the event that one of the units is disabled.
In the event that on supply needs to be replaced, the recommended method for changing
Power Modules is with the power off (to the module being removed and the module being inserted).
The system will tolerate this “cold swap” method without failure.
Each main power supply has four LEDs to indicate power supply health (OK, Input Fault,
Overtemperature, and Power Supply Fault).
Woodward | 8200-227 | SPC - Configurable Servo/Actuator Driver, CANOpen Comm 8200-227 |
Woodward | 8928-7334 | Optional Mounting Bracket – Vertical 8928-7334 |
Woodward | 8237-1242 | ProTech-SX - Panel Mount, HV/LV 8237-1242 |
Woodward | 8237-1243 | ProTech-SX - Panel Mount, HV/HV 8237-1243 |
Woodward | 8237-2594 | ProTech-GII - Bulkhead Mount, HV/LV, Independent Relays 8237-2594 |
Woodward | 8237-2595 | ProTech-GII - Bulkhead Mount, HV/HV, Independent Relays 8237-2595 |
Woodward | 8237-2596 | ProTech-GII - Bulkhead Mount, HV/LV, Voted Relays 8237-2596 |
Woodward | 8237-2597 | ProTech-GII - Bulkhead Mount, HV/HV, Voted Relays 8237-2597 |
Woodward | 8237-2598 | ProTech-GII - Panel Mount, HV/LV, Independent Relays 8237-2598 |
Woodward | 8237-2599 | ProTech-GII - Panel Mount, HV/HV, Independent Relays 8237-2599 |
Woodward | 8237-2600 | ProTech-GII - Panel Mount, HV/LV, Voted Relays 8237-2600 |
Woodward | 8237-2601 | ProTech-GII - Panel Mount, HV/HV, Voted Relays 8237-2601 |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved