Module Mounting Unit - Rear Mounting Manufacturers ABB, Bailey Model(s)
ABB Bailey Infi 90, ABB Bailey Infi 90 and Net 90
Additional Information Field power supply, 120VAC, 47-63 Hz, 250 VA
Estimated Shipping Size Dimensions: 13.0" x 7.0" x 19.0" (33.0 cm x 17.8 cm x 48.3 cm)
Weight: 8 lbs 12.0 oz (4.0kg )
Tariff Code: 8538907080
Country of Origin: United States Ships from Webster NY, USA
Module Mounting Unit - Rear Mounting
Features and benefits
Termination for up to eight (8) analog I/O process signals within a horizontal row.
All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are
100% fully compatible with each other. Thus, Singular & Redundant, Compact or Full-size I/O
modules can be mounted within a single, common HN800 I/O bus.
Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module type.
Latching device on the base locks the base into position on DIN-Rail.
Industry standard 35-mm DIN rail, Horizontal row mounting.
FEATURE
• Low-impedance busbar protection
• Stub and T-zone protection
• High functional reliability due to two independent measurement criteria:
- stabilized differential current algorithm
- directional current comparison algorithm
• Phase-by-phase measurement
• Reduced CT performance requirements
• High through-fault stability even in case of CT saturation
• Full solid-state busbar replica
• No switching of CT circuits
• Only one hardware version for
- 1 and 5 A rated currents
- all auxiliary supply voltages between 48 V DC and 250 V DC
- nominal frequencies of 50, 60 and 16.7 Hz
• Short tripping times independent of the plant’s size or configuration
• Centralized layout: Installation of hardware in one or several cubicles
• Distributed layout: Bay units distributed and, in the case of location close to the feeders, with short connections to CTs, isolators, circuit breakers, etc.
• Connections between bay units and central unit by fiber-optic cables
- maximum permissible length 1200 m
- for distributed and centralized layout
• fiber-optic connections mean interference proof data transfer even close to HV power cables
• Replacement of existing busbar protection schemes can be accomplished without restrictions
(centralized layout) in the case of substation extensions e.g. by a mixture of centralized and distributed layout
• Easily extensible
You may need the following additional products:
ABB DO02 DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DO02A DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DRMP-19 DIN-Rail Mtg Panel 19 inch Generic HW |
ABB DRMP-19SD DIN-Rail Mtg Panel 19 inch SD Series |
ABB HAI805 Analog Input Module 8-CH HART |
ABB HAI805A Analog Input Module 8-CH HART |
ABB HAO805 Analog Output Module 8-CH HART |
ABB HAO805A Analog Output Module 8-CH HART |
ABB HBS01-CJC Horiz. Base Single Cold Junction Comp. |
ABB HBS01-CJCA Horiz. Base Single Cold Junction Comp. |
ABB HBS01-EPD Horiz. Base Single Ext. Pwr Inputs |
ABB HBS01-EPDA Horiz. Base Single Ext. Pwr Inputs |
ABB HBS01-FPH Horiz. Base Single Field Pwr Hot |
ABB HBS01-FPHA Horiz. Base Single Field Pwr Hot |
ABB HBS01-FPN Horiz. Base Single Field Pwr Neutral |