Description
The 3701/55 Emergency Shutdown Device, (ADAPT ESD) is a safety PLC
with a graphical logic programming interface and integrated overspeed detection.
ADAPT ESD is designed for emergency shutdown of rotating machinery such as
steam, gas, and hydro turbines, expanders, and other process equipment.
ADAPT ESD is a compact, standalone, triple-redundant, safety shutdown device
that is designed to meet a broad range of user scenarios and applications.
The design offers an electrical and mechanical package with attention toreliability
and availability as well as extensive self diagnostics and compliance to industry standards.

Inputs
Inputs to the system are processed using three CPU modules to provide
triple modular redundancy (TMR). Each CPU processing module processes
two unique speed input channels, for a total of six speed channels for
the system. The processing modules also monitor an array of 32 discrete (DI)
and process variable (PV) signal inputs. Twelve channels of this input signal
array may be configured either as discrete inputs or 4-20 mA analog inputs.
Remaining channels in the array are reserved for discrete input signals only.
Outputs
Machinery shutdown functionality of the 3701/55 ADAPT ESD system is
actuated by TMR relay output modules. Each relay output module has five
relays with a level of configurability that accommodates a variety of applications
and requirements. Four of the five relays in each module are used to annunciate
system logic. The remaining relay reflects the OK/NOTOK status of the associated
protection path. The Bently Nevada Monitor Configuration software provides a
graphical interface to configure relay logic. The state of each relay is determined
by the system inputs and configured system logic in conjunction with thecontrol
state of the relay. Relay control states depend on the application, and may be
set as normally energized/de-energized and independent one-out-of-one, (1oo1),
voting or TMR two-out-of-three, (2oo3), voting. Each CPU module in the system
has two, internally powered, 4-20 mA recorder outputs controlled by the full-scale
speed set by the user through the Monitor Configuration software.
Compliance
The 3701/55 ESD complies with most applicable technical regulations and standards.
• North American general safety, CSA certified
• CE, Low Voltage and Electro-Magnetic Compatibility
• Functional Safety certification (SIL)
• CE, Machinery Directive
• North American, Hazardous Area certification, CSA certified
• European ATEX and IECEx Hazardous Area certification pending