Analog Output (AO)
The hardware analog output is primarily used as a process input to the controller programs,
but it can also be used a diagnostic output for various signals used in the tuning and
debugging process. The Analog Common pin is used for the signal return. The Analog
Output (AO) software parameter allows you to configure this output to represent one of the
following signals:
• Actual velocity (AO = VLA)
• Actual output current (AO = CMD)
• Following error (AO = FE)
Stepper Controller Electrical Specifications
The S2K Stepper Controller (IC800STI105xx) is suitable for use on a circuit capable of
delivering not more than 5,000 rms symmetrical amperes and 130 volts maximum when
protected by RK5 class 15A fuses. Table 2-2 summarizes the Stepper Controllers
maximum continuous input power requirements. The actual input power and current is a
function of the motor's operating point and the duty cycle.
INDUCTIVE LOAD DRIVER — Bifilar (unipolar) stepper motors can be driven directly.
The internal kickback diodes prevent damage to the output transistors by suppressing the high-voltage spikes which occur when
turning OFF an inductive load.
All LED status display codes are listed in the Motion Solutions manual.
Multiple faults are displayed on a round robin basis. The S2K Series can control a wide torque range within a single model.
The controller has a reduced package size and extensive processing power for demanding applications.
There are 2 analog inputs and one analog output on the controller, and it comes complete with one network connection.
Refer to the manual for further information about S2K controllers.
IC800STI105D2-CE is a VersaMotion S2K controller that is manufactured by GE Fanuc Automation.
This controller is a 4.3 ampere and 115/230 VAC device with resolver feedback and DeviceNet programming.
This unit has discrete inputs and outputs, position feedback, an emergency stop circuit,
a brushless servo motor, a VAC input, a serial port, auxiliary I/O, and DIP switch positions.
String variables simplify interface with third-party man-machine interfaces.
IC800STI105D2-CE supports immediate mode operation where an external host can load registers or
issue commands (over the serial or Network ports) that are executed in real time.
This controller has a real-time operating system and comprehensive programming language that supports up to four programs,
one motion task, and one communication task simultaneously executed.
We have the same series of models in stock.
If you don't find the model you need, please contact us and we will provide you with an official quotation!
GE Fanuc IC800SLCFLYZ030 Flying Lead Cable |
GE Fanuc IC800SLCBVL100 Power/Brake Cable |
GE Fanuc IC800SLCBZ050 Brake Cable |
GE Fanuc IC800SLCBZ100 Brake Cable |
GE Fanuc IC800SLCEV050 Encoder Cable |
GE Fanuc IC800SLCEV100 Encoder Cable |
GE Fanuc IC800SLCEZ050 Encoder Cable |
GE Fanuc IC800SLCEZ100 Encoder Cable |
GE Fanuc IC800SLCFLYV030 Flying Lead Cable |
GE Fanuc IC800SLCFLYZ010 Flying Lead Cable |
GE Fanuc IC800SLCPV050 Power Cable |
GE Fanuc IC800SLCPZ050 Power Cable |
GE Fanuc IC800SLCPVL100 Power Cable |
GE Fanuc IC800SLCPVL050 Power Cable |
GE Fanuc IC800SLCPV100 Power Cable |
GE Fanuc IC800SLCIZ010 Interface Cable |
GE Fanuc IC800SLCIV010 Interface Cable |
GE Fanuc IC800SLCIV030 Interface Cable |
GE Fanuc IC800SLCBVL050 Power/Brake Cable |
GE Fanuc IC800SLCIZ030 Interface Cable |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved