Power Engineering 
K-JIANG
NameDescriptionContent
  • Alstom Alspa Breakout Fuse Board 1SNL491237R010 0 Plat Surville Fusible AIT016
  • Eaton CHNSURGE Residential Surge Protector Part Number 68D8077H06 120/240V
  • ABB CT-MFS.21 1SVR630010R020 0 Multifunction Time Relay Din Rail Mount
  • Siemens 6ES7 222-1BF22-0XA0 8 Channel Digital Output
  • Phoenix Contact EEM-MA790-R - Measuring device 1576595
  • Phoenix Contact Multifunctional energy measuring devices
  • Phoenix Contact DALI module for building controller
  • Phoenix Contact Current monitoring
  • Phoenix Contact PSRcompact Safety Relays
  • Phoenix Contact TRIO POWER Power Supply
  • Phoenix Contact Buttons, switches, and indicator lights
  • Phoenix Contact 2864422 MINI MCR-SL-RPS-I-I - Repeater power supply
  • Emerson DeltaV™ M-series Zone 2 Remote I/O
  • Наша компания приняла участие в Екатеринбургской международной промышленной выставке
  • Our company participated in the Yekaterinburg International Industrial Exhibition
  • Alfa Laval Hybrid Powder Mixer S15 Powder mixers
  • Alfa Laval Hybrid Powder Mixer M15 Powder mixers
  • Alfa Laval Hybrid Powder Mixer
  • Alfa Laval Powder mixers
  • Alfa Laval RJ Mixer IM-10 Tank mixers
  • Alfa Laval Rotary Jet Mixer
  • Alfa Laval MX Mixers Mixers for fats and oils refining
  • Alfa Laval LeviMag® UltraPure Mixers
  • Alfa Laval LeviMag® Aseptic Magnetic Mixers
  • Alfa Laval Tank mixers
  • Alfa Laval EnSaLine S Agitators
  • Alfa Laval EnSaLine B Bottom Mounted agitator
  • Alfa Laval ALTB Top-mounted Agitators
  • Alfa Laval ALT top-mounted agitator with free hanging shaft
  • Alfa Laval Tank Agitators
  • Alfa Laval UltraPure pharmaceutical tubes
  • Alfa Laval Tri-Clover UltraPure ASME BPE fittings
  • Alfa Laval UltraPure pharma fittings
  • Alfa Laval Hygienic tubes
  • Alfa Laval’s hygienic fittings
  • GE MV7000 Reliable, high performance medium voltage drive
  • B&R X20cHB8815 X20 POWERLINK - TCP/IP gateway
  • Triconex 3723X Analog Input Input Module with HART Data Sheet
  • Triconex Tricon Safety Instrumented System (SIL3)
  • TMEIC Momentary Voltage Dip Multiple Power Compensator
  • TMEIC 21 G Series three-phase high-voltage motors deliver
  • TMEIC TM-AC Series 800 Frame
  • TMEIC Custom-Designed Induction Motors
  • TMEIC 21-L Series Medium Voltage Induction Motors
  • TMEIC 21-H Series three-phase high-voltage motors deliver
  • TMEIC 21-FII Series three-phase high-voltage motors
  • TMEIC 21-VLL Series Vertical Motors
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
Current Location:

E-mail

Password

Register Forgot password?
DS200LDCCH1AMA | General Electric Turbine Control Board Mark V
❤ Add to collection

DS200LDCCH1AMA | General Electric Turbine Control Board Mark V

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
U.S.$7988.00
U.S.$3445.00
Weight:2.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature

Product Description P/N: DS200LDCCH1AMA DESCRIPTION / SPECIFICATIONS Description The DS200LDCCH1AMA is a General Electric Mark V Turbine Control Board designed to manage and regulate turbine operations in power generation systems. It offers precise control over critical parameters, ensuring efficient and reliable performance. This board is essential for maintaining optimal turbine function, stability, and system integrity in demanding industrial environments. Technical Specifications Condition New / Never Used Surplus Brand General Electric Category Drives Part Number DS200LDCCH1AMA Subcategory Drive Board Series Mark V Functional Abbreviation LDCC (Drive Control and LAN Communications) Replacement for 531X301DCC, 531X306LCC, DS200SDCC, DS200SLCC Configurable Flash PROMs Yes, with connection to PC Hardware Jumpers Berg-Type (Manually Moveable) Information About DS200LDCCH1AMA The General Electric DS200LDCCH1AMA Turbine Control Board is an integral part of the Mark V series, designed to enhance the control and communication capabilities within industrial turbine drive systems. Known by its functional abbreviation, LDCC, this board serves as the Drive Control and LAN Communications unit, playing a pivotal role in the Mark V series' ability to manage complex turbine operations with precision and reliability. The DS200LDCCH1AMA is engineered to replace several earlier models, including the 531X301DCC, 531X306LCC, DS200SDCC, and DS200SLCC, making it a versatile and valuable upgrade option for existing systems. By incorporating this board, operators can benefit from improved performance, enhanced communication capabilities, and a more streamlined configuration process, ensuring that their turbine control systems remain efficient and up-to-date with the latest technological advancements. One of the standout features of the DS200LDCCH1AMA is its configurable flash PROMs, which allow for flexible and adaptable programming. This feature enables the board to be tailored to specific application requirements, ensuring optimal performance in a wide range of industrial settings. The configurable flash PROMs can be connected to a PC, allowing for easy updates and modifications to the board's programming, further enhancing its adaptability and usefulness in dynamic industrial environments. In addition to its programmable features, the DS200LDCCH1AMA is equipped with Berg-type hardware jumpers. These manually movable jumpers provide additional configurability by allowing operators to make precise adjustments to the board's settings. This manual configuration capability ensures that the board can be customized to meet the unique needs of different turbine control applications, providing a level of control that is essential for maintaining system stability and efficiency. As a member of the Mark V series, the DS200LDCCH1AMA is designed with the robustness and reliability that GE's industrial control systems are known for. The board is built to withstand the demanding conditions often found in industrial environments, ensuring long-term reliability and consistent performance. Its durable construction and high-quality components make it a dependable choice for operators seeking to maintain the integrity of their turbine control systems. The DS200LDCCH1AMA's role within the Mark V system extends beyond basic drive control. It also manages LAN communications, ensuring that the various components of the turbine control system can communicate effectively. This communication capability is critical for coordinating the complex interactions between different system elements, ensuring that the turbine operates smoothly and efficiently. The board's LAN communication functionality helps to maintain system integrity, reducing the risk of communication failures that could lead to operational disruptions. In terms of installation and integration, the DS200LDCCH1AMA is designed to be user-friendly and compatible with existing systems. Its configuration options, including the flash PROMs and hardware jumpers, are straightforward to manage, allowing operators to quickly set up and fine-tune the board for their specific needs. The board's design also facilitates easy integration into the Mark V series, making it a convenient replacement or upgrade option for operators looking to enhance their turbine control systems. The DS200LDCCH1AMA is not only an upgrade in terms of functionality but also in terms of operational efficiency. By providing advanced control and communication capabilities, this board helps to optimize turbine performance, reduce downtime, and improve overall system reliability. These benefits are critical in industrial settings where efficiency and uptime are paramount, making the DS200LDCCH1AMA an invaluable component of any turbine control system. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • Phoenix Contact Multifunctional energy measuring devices
  • Phoenix Contact DALI module for building controller
  • Phoenix Contact Current monitoring
  • Phoenix Contact PSRcompact Safety Relays
  • Phoenix Contact TRIO POWER Power Supply
  • Phoenix Contact Buttons, switches, and indicator lights
  • Phoenix Contact 2864422 MINI MCR-SL-RPS-I-I - Repeater power supply
  • Emerson DeltaV™ M-series Zone 2 Remote I/O
  • Наша компания приняла участие в Екатеринбургской международной промышленной выставке
  • Our company participated in the Yekaterinburg International Industrial Exhibition
  • Alfa Laval Hybrid Powder Mixer S15 Powder mixers
  • Alfa Laval Hybrid Powder Mixer M15 Powder mixers
  • Alfa Laval Hybrid Powder Mixer
  • Alfa Laval Powder mixers
  • Alfa Laval RJ Mixer IM-10 Tank mixers
  • Alfa Laval Rotary Jet Mixer
  • Alfa Laval MX Mixers Mixers for fats and oils refining
  • Alfa Laval LeviMag® UltraPure Mixers
  • Alfa Laval LeviMag® Aseptic Magnetic Mixers
  • Alfa Laval Tank mixers
  • Alfa Laval EnSaLine S Agitators
  • Alfa Laval EnSaLine B Bottom Mounted agitator
  • Alfa Laval ALTB Top-mounted Agitators
  • Alfa Laval ALT top-mounted agitator with free hanging shaft
  • Alfa Laval Tank Agitators
  • Alfa Laval UltraPure pharmaceutical tubes
  • Alfa Laval Tri-Clover UltraPure ASME BPE fittings
  • Alfa Laval UltraPure pharma fittings
  • Alfa Laval Hygienic tubes
  • Alfa Laval’s hygienic fittings
  • GE MV7000 Reliable, high performance medium voltage drive
  • B&R X20cHB8815 X20 POWERLINK - TCP/IP gateway
  • Triconex 3723X Analog Input Input Module with HART Data Sheet
  • Triconex Tricon Safety Instrumented System (SIL3)
  • TMEIC Momentary Voltage Dip Multiple Power Compensator
  • TMEIC 21 G Series three-phase high-voltage motors deliver
  • TMEIC TM-AC Series 800 Frame
  • TMEIC Custom-Designed Induction Motors
  • TMEIC 21-L Series Medium Voltage Induction Motors
  • TMEIC 21-H Series three-phase high-voltage motors deliver
  • TMEIC 21-FII Series three-phase high-voltage motors
  • TMEIC 21-VLL Series Vertical Motors
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?