Product Overview
Hirschmann BXS is cost‑effective gigabit managed switch series from Belden‑Hirschmann BOBCAT family, specifically designed for railway rolling‑stock on‑board networks. Certified for harsh train‑borne environments with vibration, wide temperature and strict fire & EMC requirements. Equipped with M12 railway‑grade connectors, optional PoE/PoE+ power output, TSN time‑sensitive networking and HiOS Layer 2 Advanced (L2A) firmware.
> Model portfolio includes four variants: BXS30. BXS32. BXS40. BXS42. BXS32 / BXS42 support PoE+.

Hardware Port Configuration
| Model | Port Description |
|---|---|
| BXS30 | 4 × Gigabit X‑code M12 + 8 × Fast‑Ethernet D‑code M12 |
| BXS32 | 4 × Gigabit X‑code M12 + 8 × Fast‑Ethernet D‑code M12 (PoE+ capable) |
| BXS40 | 12 × full Gigabit X‑code M12 |
| BXS42 | 12 × full Gigabit X‑code M12 (PoE+ capable) |
Key Hardware Specifications
- Local management: M12 USB‑C console port
- PoE / PoE+ (802.3af / 802.3at), max total power output 60 W
- Power input: 24 VDC or 72‑110 VDC railway supply; PoE models support 24‑48 VDC /72‑110 VDC
- Enclosure: IP40 metal housing, wall‑mount installation
- Operating temperature: ‑40 °C ~ +70 °C (observe derating rules)
- Humidity: 10‑95 % non‑condensing, max altitude 3000 m
- Weight: 2.15‑2.63 kg
Software: HiOS Layer 2 Advanced (L2A)
Management & Diagnostics
- HTML5 web‑UI, CLI, SSHv2. SNMP v1/v2/v3. IPv6 management
- Dual firmware images, ACA22‑M12‑C auto‑configuration adapter support
- Comprehensive diagnostics: multi‑mode port mirroring, RMON, copper cable test, syslog persistent logging, link‑flap detection, cold‑start self‑test.
Redundancy Protocols
HIPER‑Ring, MRP, RSTP 802.1D‑2004. LACP link aggregation, link‑backup, redundant network coupling.
Network Security
- Wire‑speed ACL access‑control‑lists, automatic DoS prevention
- 802.1X port‑based authentication, RADIUS, guest VLAN
- Multi‑level user privilege, audit trail, configurable password policy, login attempt restriction.
Real‑Time & Industrial Protocol
- TSN Time‑Sensitive‑Network support
- PTPv2 Transparent / Boundary Clock compliant with 802.1AS; SNTP client / server
- VLAN, GVRP / GMRP / MVRP, IGMP Snooping, QoS 802.1p, Jumbo frames
- Industrial protocols: PROFINET, EtherNet/IP, Modbus‑TCP, IEC 61850 MMS server
Railway Compliance & Certifications
- Rolling‑stock: EN 50155. Fire safety EN 45545 HL3. EMC EN 50121‑4
- General safety: EN 62368‑1. UL 61010‑2‑201. FCC, CE
Typical Application Scenarios
- On‑board Passenger Information System (PIS), passenger advertisement displays
- Train‑borne IP surveillance cameras
- On‑board VoIP telephones
- Passenger Wi‑Fi / WLAN access‑points
- Vehicle control auxiliary communication networks
Core Product Benefits
1. Vibration‑resistant M12 industrial connectors for moving‑train environment.
2. PoE / PoE+ power output removes separate power wiring for end devices, reduces cabling cost.
3. Built‑in TSN and PTPv2 deliver precise time synchronization for real‑time traffic.
4. Wide temperature IP40 metal enclosure, full railway‑standard certifications.
5. Rich security, redundancy and diagnostic features from mature HiOS firmware.
6. Cost‑optimized BOBCAT platform for large‑volume rolling‑stock projects.
Frequently Asked Questions
Q: What is difference between BXS and BXP?
A: BXS is cost‑optimized Layer 2‑only switch for rolling‑stock; BXP is higher‑end BOBCAT eXtreme‑Performance, supporting Layer3. 10‑GE and Bypass relay function.
Q: Which BXS models support PoE+?
A: BXS32 and BXS42 variants support PoE+ (max total power 60 W).
Q: Does BXS support TSN and PTP?
A: Yes, full TSN feature set and PTPv2 transparent / boundary clock (802.1AS).
Q: What is the operating temperature range?
A: ‑40 °C up to +70 °C; users must follow official derating specification under full‑load PoE conditions.
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com