ControlEdge™ is a next generation family of controllers providing secure connectivity
through all levels of process and business functions, optimized operations,
and maintenance efficiencies to meet your diverse automation needs.
These controllers additionally support inherent integration with Experion® systems when needed to deliver a fully cohesive automation solution.
The ControlEdge family of controllers turns data into actionable insight, from edge to enterprise, to help customers improve their bottom line.
Overview
Reduced configuration, integration, and support costs; decreased risk with
embedded cybersecurity. Minimized downtime and extended lifecycle when combined with Experion.
Uses and Examples
• Auxiliary plant applications
• Machine and equipment level control
• Water treatment
• Pump control
• Shop air supply
• Terminal management
• Coal and ash handling
Capabilities
• IEC 61131-3 Control Programming (Ladder, ST, IL, SFC, FBD)
• HART I/O for Diagnostics and Asset Management
• Universal I/O Software Configurable for Analog and Digital Signals
• Seamless Experion integration for Operator Interface and Peer to Peer Communications
• Multiple Native Communications Options (e.g. EtherNet/IP, Modbus, OPC UA)
Key Features
The 5701 Series Control System is part of the 57 System family and is designed to monitor and control field installed industrial gas detectors.
The key features of the system are as follows.
Provides up to 16 gas detection channels in a standard 19'' subrack using a 3U card format.
Provides up to 8 gas detection channels in a 3U card format in a half 19'' subrack.
Racks are available for both front and rear wiring.
Simple field connection for wires up to 2.5mm2.
Single channel operation mode for high integrity systems.
I/O Modules
The following I/O modules are available to create a custom control solution.
16 Channel Universal IO Module Galavanically isolated Input/Output to chassis (p.27)
8-point universal analog input modules: Galvanic isolation point to chassis inputs may be mixed on a module and may include multiple thermocouple types,
RTDs, ohms, voltage or mill voltage types – all easily assigned using the Process Control Designer configuration tool.
High point-to-point galvanic isolation simplifies installation and saves the expense of external isolation hardware (p.6).
16-point high level analog input module: each point is configurable for V or mA. Galvanically isolated point to
chassis. Galvanically isolated point to point (p.10). 250-ohm shunt resistors can be added per channel.
4-point galvanically isolated analog output module.
Galvanically isolated point to chassis supports from 0 to 20mA each (p.12).
8-point analog output, galvanically isolated in 2 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.13).
16-point analog output, galvanically isolated in 4 groups of 4 points. Galvanically isolated point to chassis.
Supports from 0 to 20mA each (p.14).
16-point digital input modules: Contact closure type, DC Voltage, AC Voltage and AC/DC voltage types (p.15).
Galvanically isolated in groups of 8 channel to chassis
32-point digital input module: DC voltage. Galvanically isolated point to chassis. Galvanically isolated in 2
groups of 16 points (p.1915).
8-point AC or 16-point DC digital output modules (sinking type). Galvanically isolated point to chassis.
Galvanically isolated in 2 groups of 8 points (p.18).
32-point digital output: DC voltage (sourcing type).
Galvanically isolated point to chassis. Galvanically isolated in 2 groups of 16 points (p.23).
8-point relay output module: four form C type and four form A type relays.
Galvanically isolated point to chassis. Galvanically isolated relay to relay (p.20).
4 channel Pulse/Frequency/Quadrature I/O module.
Galvanically isolated point to chassis (p.24).
Remote Terminal Panels
Optional DIN rail mounted Remote Terminal Panels (RTPs) are available for use with pre-wired cables to reduce installation time and labor expense.
Four types of RTPs are available: analog inputs, relay outputs, redundant I/O and other I/O modules.
Three cable lengths are also available to match hardware to installation variations.
Analog inputs RTPs include transmitter shunt resistors and transmitter power terminals with individual circuit fuses.
The Relay Output RTP includes a fuse and power disconnect switch for each output.
All the three types of RTP panels also switch power to allow module removal and installation under controller power.
Other advantageous products on sale are listed below:
EMERSON SE4017P1 S-series H1 I/O Card with Integrated power and Terminal Block
EMERSON SE4037P1 Redundant S-series H1 I/O Card with Integrated power and Terminal Block
EMERSON S-series Virtual I/O Module 2
EMERSON S-series Virtual I/O Module 2 SE4026
EMERSON SE4027 Redundant S-series Virtual I/O Module 2
EMERSON S-series Profibus DP Interface Card
EMERSON SE4022 S-series Profibus DP Interface Card
EMERSON SE4038 S-series Redundant Profibus DP I/O Interface
EMERSON SE4006P2 S-series Serial Interface Card, 2-ports
EMERSON SE4036P2 Redundant S-series Serial Interface Card, 2-ports
EMERSON S-series Sequence of Events Card
EMERSON SOE interface with 32-screw termination block SE4001S5T2B4
EMERSON SOE interface with Mass term block Connector SE4001S5T2B5
EMERSON S-series Horizontal Carriers
EMERSON Carrier Blank Cap (for 8-Wide I/O Interface Carrier only) SE6101
EMERSON Carrier Blank Cap (for 2-Wide Power and Controller Carrier only) SE6102
EMERSON Left Extender 1-Wide KJ4005X1-BB1
EMERSON Right Extender 1-Wide KJ4005X1-BC1
EMERSON Single Carrier Extender Cable 0.4m (17in) KJ4003X1-BH2
EMERSON Single Carrier Extender Cable 0.8m (31in) KJ4003X1-BH3
EMERSON Single Carrier Extender Cable 1.1m (43in) KJ4003X1-BH1
EMERSON Single Carrier Extender Cable 1.5m (58in) KJ4003X1-BH4
EMERSON Single Carrier Extender Cable 1.9m (77in) KJ4003X1-BH5
EMERSON Power Terminal Plug for 2-Wide and 8-Wide Carriers KJ4005X1-BF1
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved