Internal or external triggering is possible.
Measurement time is 0.8 seconds for a span of 200 nm and varies with the span.
Broadband light sources with a resolution of 5 nm have the highest sensitivity,
while narrowband light sources (lasers) can be reliably analyzed down to the noise level even with a narrow resolution bandwidth.
The normalization function combined with the white light source allows direct measurement of transmission and loss characteristics of filters and fibers.
Key Features
- Sensitivity -92 dBm
- Polarization correlation ±0.05 dB
- Resolution bandwidth accuracy ±2
- Power Measurement
- Pulsed light measurement
The advantage of the old 6581 is that there is a reverse enginered schematics available, if needed for a repair.
As a downside the displays are often dim and a replacement is a bit tricky.
A know weak point for the 6581 is the rather large current spike from AZ switching - this can be an issue with some signal sources.
Another point is that ACAL may not be fully accurate for the highest resistor ranges.
So the specs there may be a bit overly optimistic.
Quite a few of the old meters also have a relay power saving mode not working right
that can cause some thermal EMF error that can effect the lower voltage ranges - this is fixable at least.
The 6581T tends to have a rather poor factory calibration that causes quite some INL error
- so while the ADC is essentially the same as with the full version, the linearity is not that great for the T version.
There may be ways to correct this, but it is extra effort and may need extra instruments (e.g. cal source).
Operation
In addition to amplifier analysis, a variety of display modes are available, such as
- Overlay display,
- Comparison with memory contents,
- Display of two independent graphs (split screen),
- Power meter function,
- Use of multiple markers,
- Normalized and direct readout of transmission loss and
- Automatic bandwidth analysis (e.g. measurement of half-value widths based on RMS and envelope methods),
- Curve fitting over the IEC/IEEE bus and many other features facilitate operation of the analyzer and simplify analysis.
A standard internal disk drive is used as a storage medium. Stored binary data can be analyzed with the appropriate program under MS-Windows or copied to a file and printed out.
The high-speed built-in thermal printer prints out a hard copy of the measurement results with all setup parameters in less than 10 seconds. The built-in high-speed thermal printer prints a hard copy of the measurement results with all setup parameters in less than 8 seconds.
Recommended Products P/N:
Advantest BGC-022641 Memory RAM PGC-622641BB2 Module 01537 |
Advantest BGC-024741 |
Advantest BGD-02097 BOARD |
Advantest BGD-022241 BA BOARD |
Advantest BGD-022242 BB BOARD |
Advantest BGD-022555 PGD-422555BB2 |
Advantest BGD-023054 BGD023054 |
Advantest BGD-024401 for M6541AD |
Advantest BGD-026363 FedEx 90days Warranty |
Advantest BGG-029070 _ PPG-829070DD _ TKK-5 BOARD |
Advantest BGK-024673 board |
Advantest BGL-015413 Board_Used_Japan_95862 |
Advantest BGR-017417 PCB_ HVPPS CONTROL |
Advantest BGR-024356 TGFC I F BOARD |
Advantest BGR-024841 PCB 1998 f r Eine T5371 |
Advantest BIR-026382 Tabla - Fair Condici |
Advantest BIR-26805 Board |
Advantest BLB-017407 GPIB Connector Card Board A1910ZB |
Advantest BLB-019431 Fan Rotation Sensor PLB-219431AA1 JAP |
Advantest BLB-025841 Circuit Board PCB PLB-420972BB2 M4542 |
Advantest BLB-027895 Circuit Board PCB PLB-420972BB2 M4542 |
Advantest BLC-015681 Tracking generator for R3361A R3361B_ |
Advantest BLC-029524 PCB Circuit Board M4542ADg |
Advantest BLD-024486 Processor PCB Card PLD-424486CC |
Advantest BLG-015240 Board_Used_Japan_95863 |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved