Termination Cable Manufacturers ABB
Bailey Model(s) ABB Bailey Infi 90, ABB Bailey Infi 90 and Net 90
Additional Information Infi-Net Termination Cable NKTT01-4, connects two NTCL01 or NICL01 modules, 4 feet long
Estimated Shipping Size Dimensions: 10.0" x 1.0" x 10.0" (25.4 cm x 2.5 cm x 25.4 cm)
Weight: 0 lbs 6.1 oz (0.2kg )
Tariff Code: 8544429000
Country of Origin: United States Ships from Webster NY, USA
Termination Cable
Concept
AC010 logic modules are suitable for small and medium-sized
control tasks and are able to substitute logic wiring in a quick and
easy manner.
They can be used for applications in control as well as for timing
functions, e. g.
in buildings, lighting systems, air-conditioning systems,
general control functions,
in small machines and systems or
as stand-alone control module for small applications.
Steps to the application of AC010
AC010 can be used easily, rapidly and comfortably without any
time-consuming planning and programming.
The user can discover the advantages and the benefi t of these
logic modules in no time at all.
Features and benefits
Termination for up to eight (8) analog I/O process signals within a horizontal row.
All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are
100% fully compatible with each other. Thus, Singular & Redundant, Compact or Full-size I/O
modules can be mounted within a single, common HN800 I/O bus.
Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module type.
Latching device on the base locks the base into position on DIN-Rail.
Industry standard 35-mm DIN rail, Horizontal row mounting.
Application areas of 086349-002 BB 41055 stepper linear control motherboard:
Distribution automation applications:
Automatic reclosing: A circuit breaker used for automatic reclosing tripping to handle instantaneous faults.
Automatic recovery: The 086349-002 BB 41055 stepper linear control motherboard isolates faults through a patented load transfer scheme and restores
Distribution capacitor control algorithm: more effectively utilize existing capacitor banks to achieve peak cycles.
Fault location: locate and isolate faults to reduce customer downtime.
Load and dead bus transmission: Monitor the substation network and transfer the load of overloaded transformers to other substations.
Load shedding/limiting: Provide intelligent load shedding conditions during overload.
Data recording/storage applications:
SOE local recorder: Record digital and analog SOEs to an external printer, PC, or CSV file.
Accumulator freeze: Coordinate the freeze of the accumulator group.
Event storage: Stores a historical record of the current value, status, and timestamp, and can store up to 7 days of simulation and accumulator data.
Historical simulation: stores the average historical value of 8 additional analog inputs.