Power Engineering 
K-JIANG
NameDescriptionContent
  • GE IS420ESWAH5A Mark VIe IONet Switch
  • GE IS420ESWAH4A Mark VIe IONet Switch
  • GE IS420ESWAH2A Mark VIe IONet Switch
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0124 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521-0025 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A, ground switching
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A
Current Location:

E-mail

Password

Register Forgot password?
GE IS200DSPXH1D DRIVE DSP CONTROL CARD
❤ Add to collection

GE IS200DSPXH1D DRIVE DSP CONTROL CARD

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
IS200DSPXH1D
U.S.$10055.00
U.S.$4548.00
Weight:0.000KG
Quantity:
(Inventory: 5)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
IS200DSPXH1D

Part Number IS200DSPXH1D Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2100e Function Module Availability In StockIS200DSPXH1D is a Digital Signal Processor Control Board developed by GE. It is the primary controller for the Innovation Series drives' bridge, motor regulator, and gating operations. It also manages the EX2100 Excitation Control's generator field control functions. The logic, processing, and interface functions are all provided by the board. The DSPX board is comprised of a high-performance digital signal processor (DSP), standard memory components, and an application-specific integrated circuit (ASIC) that performs custom logic functions. Standard Hardware Features The Digital Signal Processor (DSP) of the DSPX runs at 60 MHz. There are four externals. During normal operation, the DSP receives interrupts: Stack overflow (INT0) A load pulse in the inner loop (INT1) There are two inputs that can be customized (INT2, INT3) The DSPX board supports the following types of memory: DSP boot images, code execution, configurable item storage, and system history records are all stored in FLASH memory. RAM is used to store data and run programs.

NVRAM stands for nonvolatile random access memory. Add-only memory for identifying board revisions Both the foreground stack (from internal memory) and the background stack have overflow detection (from external SRAM). If either stack overflows, an interrupt INT0 is generated. A hard reset is generated if both stacks overflow. A configuration register is provided to disable the stack overflow reset. The DSP activates and periodically toggles a watchdog timer (toggle interval is configurable). A watchdog timer timeout will result in a hard reset. A free running timer of 24 bits is also provided and is used as a reference for certain functions. As two quadrature incremental tach interfaces, five differential (HIFI) pair application inputs can be used (one with marker capability). Two 16-bit up/down counters are driven by the signals. When the inputs are at the same level, it maintains its current state; when the inputs are differentially opposite, it changes state. Each time the counter increments or decrements, a 5 MHz timer resets, and a state register records the direction of the last count.

A capture register is associated with each of these counters, timers, and registers and can be configured to capture the values on the occurrence of either the inner loop load pulse or the application loop load pulse. The five differential HIFI inputs can be used as VCO counters in the application layer or as single-channel tach interfaces. On the differentially decoded and filtered inputs, five 16-bit counters increment. The application loop load pulse stores these counter values in registers that the DSP can read. Up to ten discrete inputs can be used in addition to the five differential HIFI inputs. Each input is filtered for three system clock cycles before being read directly by the DSP into a buffer. Custom logic in Field Programmable Gate Arrays (FPGAs) or ASICs with supporting circuits are used to provide specialized functions on the DSPX board. ASICs contain the majority of specialized and support functionality. P1 has four serial interfaces, which are as follows: Two 5 Mb/s ISBusTM interfaces that can be used as master or slave One asynchronous TTL interface for a computer-based configuration tool, with RX, TX, and TXEN/RTS data signals One asynchronous TTL interface to a programmer board, including data signals RX, TX, and RTS The following functions are carried out by synchronizing load pulse signals: An inner loop load pulse signal records I/O values such as bridge, motor, or generator voltages and currents, as well as VCOs, tachometer counters, and discrete inputs. It can also synchronize ISBus channels, software, and bridge gating outputs. An application loop load pulse signal is used to capture values of other application VCOs and optionally the tachs at a sub-multiple or multiple of the inner loop load pulse. Onboard Firmware Flash memory is used to store onboard firmware.

The following are the three primary types: The boot loader is responsible for the start-up sequence and should not be reloaded in the field. The application code for the drive or exciter product defines the specific control functionalities. The exciter's Tool port is used to load the code, while the toolbox is used to load the configuration parameters. The Unit Data Highway is used to load the exciter parameters. If applicable, drive parameters are loaded to ACL_ through a serial port, ISBus, or Ethernet. Application Data A 4-row, 128-pin DIN connector connects the DSPX board to the backplane, which is located in the board rack (P1). The DSPX is connected to another board, the EISB, in the EX2100. I/O Definitions The DSPX has three I/O connectors, which are as follows: Backplane connector P1 Port for P5 DSP emulator P6 monitoring port for engineering The P1 connector supports bridge and customer input/output (I/O) interfaces with memory-mapped process bus address space and four chip select signals. Individual controls are also provided for a normal UART serial interface to a programming board and a setup tool, as well as two additional ISBus proprietary serial connections for ACL or local extension features. The P5 emulator port (on the front panel of the board) connects to the TI emulator port. The P6 engineering monitor port (on the board's front panel) connects to the DSP synchronous serial port (at TTL levels) and allows connection to a GE engineering terminal only.

  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0124 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521-0025 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A, ground switching
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A, timestamping
  • SAACKE ATONOX THE ULTRA-LOW-NOX BURNER FOR YOUR LARGE-SCALE COMBUSTION
  • SAACKE Pulverized fuels.
  • SAACKE SPECIAL GASES.
  • SAACKE Special liquid fuels
  • SAACKE BIOFUELS. Biogenic fuels
  • SAACKE IGNITION AND SUPPORT BURNERS.
  • SAACKE WATER TUBE BOILERS.
  • SAACKE Thermal processing systems
  • SAACKE MODERN LOW-NOX BURNERS FOR ALMOST ANY FUEL
  • SAACKE GreenDock ZERO EMISSION ENERGY IN PORT.
  • SAACKE WASTE HEAT RECOVERY UNIT.
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • Meggitt P702B/P702BF-1 Power unit/amplifier
  • Meggitt VibroSmart® Distributed Monitoring System (DMS)
  • HIMA DI 24 01 HIMatrix Safety-Related Controller
  • HIMA DIO 24/16 01 HIMatrix Safety-Related Controller
  • HIMA X-CI 24 51 HIMax® Counter Module
  • HIMA X-DI 64 51 HIMax®Digital Input Module
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?