PACSystems™ RX3i Controllers
Industrial Internet Ready
▪ Simple configuration, maintenance and operation
▪ Single point of connect no matter what distance
▪ High-speed communication for real-time control
▪ High Availability support for maximum up-time
Introduction
The PACSystems RX3i family provides advanced diagnostics and high performance I/O.
With a modular design and multiple expansion options, RX3i is the perfect I/O solution for your process, hybrid,
and discrete applications.
Modular, High-Speed Performance RX3i is a rack-based system with a wide range of modules covering digital,
analog, and numerous other specialty I/O types.
These pluggable and hot-swappable modules allow you to customize the right mix of I/O, with a variety of voltage ranges and current capacities supported to meet
all your application needs. Regardless of the I/O mix you choose, RX3i is built on high speed interfaces to provide rapid and consistent data transfer.
Highly Scalable
With the ability to pair I/O, RX3i allows you to scale your system with ease.
In addition to I/O that you can put on the main rack, you can expand locally or remotely to connect to additional racks of I/O.
In fact, RX3i can support as few as 8 I/O points and up to 32 thousand I/O points in a single system.
With 7 to 16 slot backplanes and 1 slot expansion options, you can create the perfect system to fit your needs.
Function of cable
The I/O Interface Cable assembly consists of a 24-pin I/O connector, a cable, and a 25-pin D-type terminal block connector.
This cable is used to connect the Power Mate APM Modules (IC693APU301 and IC693APU302) to drives and machines.
There are two male 24-pin connectors mounted on the front of each Power Mate APM.
Two of these I/O Interface cables are required for connections to and from the drive and machine.
Catalog number IC693CBL311 is 10 feet (3 meters) in length and IC693CBL319 is 3 feet (1 meter) in length.
An I/O cable assembly similar to IC693CBL311 and IC693CBL319,
but with the drain shield wire disconnected from pin B12 and brought outside of the cable housing through an 8”pigtail,
is also available in two lengths. Catalog number IC693CBL317 is 10 feet (3 meters)
in length and IC693CBL320 is 3 feet (1 meter) in length.
This cable improves the Power Mate APM’s noise immunity.
The cable wire code list for these cables is provided in Table 10-5.
To make wiring to the drive and machine easier, each connector on the module is typically connected by
a a short cable (the I/O Interface cable) to a terminal block.
The cable that connects from the I/O connector to an external terminal block can be shortened to meet the requirements of your installation.
See manuals GFK-0840 (standard moed) or GFK-0781 (follower mode) for details on APM terminal blocks.
Wiring Information
You must purchase the mating female (socket type) 24-pin connectors (which mate with the I/O Connector on the faceplate of the APM).
This connector is available under catalog number IC693ACC317.
This connector has a solder eyelet receptacle and is part of an accessory kit. Optionally,
other types of the 24-pin connector (for different physical connections) are also available.
Catalog numbers for these connectors and their associated parts are listed in the following table.
The list includes catalog numbers for three types of connectors: solder pin, crimp pin, and ribbon cable.
Each accessory kit contains enough components (D-connectors, backshells, contact pins, etc.)
to assemble ten single-ended cables of the type specified for each kit.
System Configurations
The Mini Converter can be used in a point-to-point configuration as described above,
or in a multidrop configuration with the host device configured as the master and one or more programmable controllers configured as slaves.
The multidrop configuration requires a straightthrough (1-to-1) cable from the Mini Converter’s RS-422 port to the first slave PLC’s SNP port.
Other slaves will require a daisy chain connection between slaves.
A maximum of eight devices can be connected in an RS-422 multidrop configuration.
All of the devices must have a common ground.
If ground isolation is required, you can use the Isolated Repeater/Converter (IC655CCM590) in place of the Mini Converter.
When using the Mini Converter with a modem connection,
it may be necessary to jumper RTS to CTS (consult the user’s manual for your modem).
Cable Diagrams (Point-To-Point) When connecting the Mini Converter to IBM PC and compatible computers with hardware handshaking,
the following cable connections should be used.
IC697VSC096 Single Board Computer | IC697PWR721RR Power Supply, 24 Vdc, 90 Watts, w/Power Supply Adaptor |
IC698ACC701 RX7i CPU Lithium Battery and Spare Door | IC697PWR722RR Replacement Power Supply, 24 Vdc, 90 Watts |
IC698ACC720 Shielded double slot faceplate, package of six. | IC697PWR724 Power Supply, 24 Vdc, 90 Watts |
IC698ACC735 Shielded single slot faceplate, package of six. | IC697PWR724RR Power Supply, 24 Vdc, 90 Watts |
IC698CHS009 RX7i 9 Slot Rear Mount Rack | IC697PWR731RR Power Supply, 125 Vdc, 60 Watts, w/Power Supply Adaptor |
IC698CHS017 RX7i 17 Slot Rack Wall (Rear) Mount | IC697PWR732RR Replacement Power Supply, 125 Vdc, 60 Watts |
IC698CHS109 RX7i 9 Slot Rack Front Mount | IC697PWR748 Power Supply, 48 Vdc, 90 Watts |
IC698CHS117 RX7i 17Slot Rack Front Mount | IC697PWR748RR Power Supply, 48 Vdc, 90 Watts |
IC698CHS117CA RX7i 17Slot Rack Front Mount Conformal Coated | IC697RCM711 Hot Standby Redundancy Communications Module |
IC698CHS217 RX7i 17 Slot Rack Rear I/O Mount | IC697RCM711RR Redundancy Communications Module (Hot Standby Redundancy) |
IC698CMX016 PACSystems RX7i Control Memory Xchange 16MB Memory | IC697VAL132 Discontinued |
IC698CPE010 Do not quote. Product discontinued | IC697VAL134 Module discontinued |
IC698CPE020 RX7i 700mhz CPU with Ethernet 10/100 | IC697VAL216 Remplacement is Embedded VME-3122A-420000 |
IC698CPE030 RX7i Pentium M CPU - 600mHz with 64 meg of user memory | IC697VAL232 Replacement is Embedded VME-3122A-410000 |
IC698CPE040 RX7i Pentium M CPU - 1.8Ghz with 64 meg of user memory | IC697VAL264 Relplacement is Embedded VME-3122A-400000 |
IC698CRE020 PACSystems RX7i High Availability 700mHz CPU | IC697VAL301 Replacement is Embedded VME-4132-010000 |
IC698CRE020CA RX7i 700mhz Redundant CPU w/Ethernet Conformal Coated | IC697VAL304 Discontinued future replacement with Embedded VME-6550 |
IC698CRE030 600MHZ CPU, ETHERNET, REDUNDANCY | IC697VAL306 Discontinued, future replacement is Embedded VME-6500 |
IC698CRE040 1.8GHZ CPU, ETHERNET, REDUNDANCY | IC697VAL308 Discontinued, future replacement is Embedded VME-6550 |
IC698ETM001 RX7i Standalone Ethernet Module 10/100 | IC697VAL314 Discontinued, no replacement |
IC698ETM001CA RX7i 10/100 Ethernet Module Conformal Coated | IC697VAL318 Discontinued, replacement is Embedded VME-6550 |
IC698PSA100 RX7i Power Supply 100Watt 85-264VAC | IC697VAL324 Discontinued, replacement is Embedded VME-6550 |
IC698PSA350 RX7i Power Supply 350Watt 85-264VAC | IC697VAL328 Discontinued, replacement is Embedded VME-6550 |
IC698PSD300 RX7i Power Supply 300Watt 24VDC | IC697VAL348 Discontinued, future replacement is Embedded VME-6500 |
IC698RMX016 PACSystems RX7i Redundant Memory Xchange 16MB Memory | IC697VDD100 Discontinued. Replacement is Embedded VME-1182A-020000 |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved