Power Engineering 
K-JIANG
NameDescriptionContent
  • Triconex 3723X Analog Input Input Module with HART
  • GE IS420ESWAH5A Mark VIe IONet Switch
  • GE IS420ESWAH4A Mark VIe IONet Switch
  • GE IS420ESWAH2A Mark VIe IONet Switch
  • Basler Electric BE1-25, Sync-Check Relay
  • Triconex 3723X Analog Input Input Module with HART Data Sheet
  • Triconex Tricon Safety Instrumented System (SIL3)
  • TMEIC Momentary Voltage Dip Multiple Power Compensator
  • TMEIC 21 G Series three-phase high-voltage motors deliver
  • TMEIC TM-AC Series 800 Frame
  • TMEIC Custom-Designed Induction Motors
  • TMEIC 21-L Series Medium Voltage Induction Motors
  • TMEIC 21-H Series three-phase high-voltage motors deliver
  • TMEIC 21-FII Series three-phase high-voltage motors
  • TMEIC 21-VLL Series Vertical Motors
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
Current Location:

E-mail

Password

Register Forgot password?
DS200SLCCG1AEF | General Electric Mark V LAN Communication Board
❤ Add to collection

DS200SLCCG1AEF | General Electric Mark V LAN Communication Board

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
DS200SLCCG1AEF | General Electric Mark V LAN Communication Board
U.S.$7759.00
U.S.$2025.00
Weight:2.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
DS200SLCCG1AEF | General Electric Mark V LAN Communication Board

Product Description P/N: IS200DRTDH1A DESCRIPTION / SPECIFICATIONS Description The IS200DRTDH1A is a PCB (printed circuit board) component developed by GE as part of their Mark VI Speedtronic system, designed for the management of gas and steam turbines. The acronym "DRTD" signifies DIN-Rail Resistance Temperature Detector. RTD terminal boards serve as resistance temperature detectors, offering galvanic isolation or transient protection for the connected system. Depending on the configuration and type, RTDs can provide simplex, dual, or TMR (Triple Modular Redundant) control. The IS200DRTDH1A is designed for DIN-rail mounting, featuring a DIN rail carrier encompassing all sides. Marked with codes like PLC-4, 6DA00, and 6BA01, the board also includes a barcode attached near one short edge for identification purposes. Despite its minimalistic design, the IS200DRTDH1A comprises essential components, including a d-shell female connector with screw connections for cable attachment, a euro-block style two-level terminal block, an integrated circuit, and two rows of capacitors. Additionally, the board features drilled holes in two corners to facilitate installation. Technical Specifications Part No. IS200DRTDH1A Manufacturer General Electric Product Type Din Rail Terminal Board - RTD Span 0.3532 to 4.054 V Maximum lead resistance 15 ohm maximum two-way cable resistance Number of Channels Eight channels Country of Manufacture United States (USA) Series Mark VI Information About IS200DRTDH1A The General Electric IS200DRTDH1A is a high-quality Din Rail Terminal Board designed for Resistance Temperature Detector (RTD) applications. Part of the advanced Mark VI series, this terminal board is engineered to provide precise and reliable temperature measurement capabilities, essential for various industrial processes. Manufactured in the United States, the IS200DRTDH1A reflects General Electric's commitment to excellence and innovation in industrial automation technology.

The IS200DRTDH1A features eight channels, allowing for multiple RTD inputs to be connected simultaneously. This multi-channel capability is crucial for applications requiring the monitoring of multiple temperature points within a system. Each channel ensures accurate temperature readings, enhancing the overall control and monitoring of industrial processes. This terminal board operates within a voltage span of 0.3532 to 4.054 V, providing a wide range for accurate temperature detection and measurement. This span ensures that the board can accommodate various RTD types and configurations, offering flexibility for different application requirements. The ability to handle a broad voltage range makes the IS200DRTDH1A a versatile solution for diverse industrial environments. One of the key specifications of the IS200DRTDH1A is its maximum lead resistance capability, which is 15 ohms for two-way cable resistance. This feature ensures that the board can maintain accuracy and reliability even with longer cable runs, which are common in large industrial setups. By accommodating higher lead resistance, the IS200DRTDH1A ensures consistent and precise temperature measurements across the entire system. Designed for DIN rail mounting, the IS200DRTDH1A offers easy installation and integration into existing control systems. The DIN rail mounting feature simplifies the setup process, allowing for secure and efficient placement within control cabinets. This design also facilitates easy maintenance and replacement, reducing downtime and enhancing operational efficiency. The IS200DRTDH1A is part of the Mark VI series, known for its advanced control and automation solutions. The integration of this terminal board into the Mark VI system enhances its functionality, providing robust and reliable temperature measurement capabilities. The Mark VI series is designed to meet the demanding requirements of modern industrial applications, and the IS200DRTDH1A upholds these high standards. Manufactured in the United States, the IS200DRTDH1A adheres to stringent quality control measures, ensuring high performance and durability. General Electric's focus on quality and reliability is evident in the construction and design of this terminal board, making it a dependable choice for critical industrial applications. In summary, the General Electric IS200DRTDH1A Din Rail Terminal Board for RTD applications is a high-performance component designed for accurate and reliable temperature measurement. With eight channels, a wide voltage span, and the ability to handle high lead resistance, it offers versatile and precise monitoring capabilities. The DIN rail mounting feature ensures easy installation and integration, while its manufacture in the USA guarantees high quality and durability. As part of the Mark VI series, the IS200DRTDH1A enhances the functionality of industrial control systems, making it an essential component for efficient and reliable temperature management in various industrial environments. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • Triconex 3723X Analog Input Input Module with HART Data Sheet
  • Triconex Tricon Safety Instrumented System (SIL3)
  • TMEIC Momentary Voltage Dip Multiple Power Compensator
  • TMEIC 21 G Series three-phase high-voltage motors deliver
  • TMEIC TM-AC Series 800 Frame
  • TMEIC Custom-Designed Induction Motors
  • TMEIC 21-L Series Medium Voltage Induction Motors
  • TMEIC 21-H Series three-phase high-voltage motors deliver
  • TMEIC 21-FII Series three-phase high-voltage motors
  • TMEIC 21-VLL Series Vertical Motors
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0124 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521-0025 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A, ground switching
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A, timestamping
  • SAACKE ATONOX THE ULTRA-LOW-NOX BURNER FOR YOUR LARGE-SCALE COMBUSTION
  • SAACKE Pulverized fuels.
  • SAACKE SPECIAL GASES.
  • SAACKE Special liquid fuels
  • SAACKE BIOFUELS. Biogenic fuels
  • SAACKE IGNITION AND SUPPORT BURNERS.
  • SAACKE WATER TUBE BOILERS.
  • SAACKE Thermal processing systems
  • SAACKE MODERN LOW-NOX BURNERS FOR ALMOST ANY FUEL
  • SAACKE GreenDock ZERO EMISSION ENERGY IN PORT.
  • SAACKE WASTE HEAT RECOVERY UNIT.
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?