Operation
In addition to amplifier analysis, a variety of display modes are available, such as
- Overlay display,
- Comparison with memory contents,
- Display of two independent graphs (split screen),
- Power meter function,
- Use of multiple markers,
- Normalized and direct readout of transmission loss and
- Automatic bandwidth analysis (e.g. measurement of half-value widths based on RMS and envelope methods),
- Curve fitting over the IEC/IEEE bus and many other features facilitate operation of the analyzer and simplify analysis.
Internal or external triggering is possible.
Measurement time is 0.8 seconds for a span of 200 nm and varies with the span.
Broadband light sources with a resolution of 5 nm have the highest sensitivity,
while narrowband light sources (lasers) can be reliably analyzed down to the noise level even with a narrow resolution bandwidth.
The normalization function combined with the white light source allows direct measurement of transmission and loss characteristics of filters and fibers.
Generation : PHS, PDC, IS-136. GSM, DECT, EDGE, GPRS IS-95. W-CDMA/3GPP, cdma2000. Bluetooth
The Advantest R3267 spectrum analyzers provide accurate, repeatable measurements of high-quality
digital signals in the 2GHz band ± within 1% frequency span accuracy and -154dBc/Hz dynamic range (typical).
Key Features
- Sensitivity -92 dBm
- Polarization correlation ±0.05 dB
- Resolution bandwidth accuracy ±2
- Power Measurement
- Pulsed light measurement
The advantage of the old 6581 is that there is a reverse enginered schematics available, if needed for a repair.
As a downside the displays are often dim and a replacement is a bit tricky.
A know weak point for the 6581 is the rather large current spike from AZ switching - this can be an issue with some signal sources.
Another point is that ACAL may not be fully accurate for the highest resistor ranges.
So the specs there may be a bit overly optimistic.
Quite a few of the old meters also have a relay power saving mode not working right
that can cause some thermal EMF error that can effect the lower voltage ranges - this is fixable at least.
The 6581T tends to have a rather poor factory calibration that causes quite some INL error
- so while the ADC is essentially the same as with the full version, the linearity is not that great for the T version.
There may be ways to correct this, but it is extra effort and may need extra instruments (e.g. cal source).
Recommended Products P/N:
Advantest BLM-027101 X15 |
Advantest board P N BGL-018817 |
Advantest BPG-032802 PPG-632802882BBA |
Advantest Control Box H3-5046 Trigger Box |
Advantest Control Box KH3-911028 and Cables NEW wit |
Advantest Control Box Remote H3-5068X03 ship |
Advantest Coroperate BGK-014335 _212093-AH1 |
Advantest Corporation BGF-029873 Module Card Board for |
Advantest Corporation BGR-030242 A051024 Card Board PCB |
Advantest digital multimeter ADCE 7351E-00JA |
Advantest Dolphin TEF810X |
Advantest E8010-69511 |
Advantest FOE-8311231M01 R3261 3361 Series Spectrum Analyz |
Advantest H3-5058-9302B H3-5058 Trigger Box |
Advantest H3-5068 H35068 Control Box C |
Advantest H4-4075-9652U CB1 R4691-046 D1960 D1961 |
Advantest H4-4111 7 Axis Stepper Controller Rack Ve |
Advantest H4-7053 M6751AD 250V AC POWER SUPPLY CONT |
Advantest IN502-01 for M6541AD |
Advantest IN502-01-B for M6541AD |
Advantest Interface Module WUN-H36499 |
Advantest KH3-71166 |
Advantest M6541 6542 TOUCH MONITOR UT3-15GX1RD |
Advantest M6541AD TOUCH MONITOR 10 |
Advantest MEP-WBL-4131YTO - TOP 1242 YTO 4 to |
Advantest OED00 9303 R9211B C FFT Servo Analyzer |
Advantest PGH-618830BB2 BGH-018830 |
Advantest PLB-420972BB2 BLB-020972 & BLB-020986 for M6541A |
Advantest Q7605B Lightwave Modulation Test Set - AS |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved