Reduced installation time and expense: The DeltaV system’s
S-series I/O interfaces are designed for quick assembly and
error proof maintenance. All carriers snap onto T-DIN rails and
interfaces snap into the I/O slots without the use of any tools.
Each I/O interface has a separate wiring terminal block,
which connects field wiring to the interface. The I/O card can
easily be removed without touching the I/O wiring on the
terminal block. Some I/O cards can also use the fused terminal
block, which is equipped with in-line fuses that can be pulled
to isolate power to the field circuit.

Traditional I/O interfaces have I/O function keys that allow
the terminal block to be set to receive a specific I/O card.
These keys ensure that the correct I/O card is always plugged
into the corresponding terminal block. The keys provide a
safety measure by preventing the wrong I/O card being
installed. It’s incredibly easy to use and gives you time to do more.
Rosemount 3051C Coplanar Pressure Transmitters are the
industry standard for differential, gage, and absolute pressure
measurement. The coplanar platform enables seamless
integration with manifolds, flow, and level solutions.
■ Loop Integrity and Plugged Impulse Line Diagnostics detect
issues that might compromise the integrity of the output
signal (code DA1).
■ Bluetooth® Connectivity enables efficient, reliable, and safe
configuration and maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability
(code M6).
■ Safety certification and proof testing (code QT and T9).
Redundant I/O cards are available for critical applications.
The same card can be used in simplex or redundant
applications. When installed on a two-wide redundant terminal
block, the cards are recognized as a redundant pair by the
controller. The controller scans each card and determines which
card is acting as the active interface. When a fault is detected,
the system automatically switches to the standby I/O card.
DeltaV control modules reference simplex and redundant
I/O channels identically and there is no special configuration
required to take advantage of redundancy.
WOODHEAD SST DHP-PCI V1.2.0 SD-PCI-U DATA HIGHWAY PLUS INTERFACE CARD
Molex SST-PB3-VME-2 Brad Communication Board SSTPB3VME2E
SST Woodhead SST-ESR2-CLX-RLL Ethernet Modbus/Serial Modbus Communication
Emerson PR6423/011-110+C0N021 Eddy Current Signal Converter
Emerson PR6426/010-110+C0N021/916-240 Eddy Current Signal Converter
Emerson Rosemount 3051S Wireless Pressure Transmitter
Emerson Rosemount 3051SMV Wireless Pressure Transmitter
Emerson Rosemount 648 Wireless Temperature Transmitter
Emerson Rosemount 848T Wireless Temperature Transmitter
Emerson Rosemount 3308A Wireless Guided Wave Radar
Emerson Rosemount 2160 Wireless Level Switch
Emerson Rosemount 928 Wireless Gas Monitor
Emerson Rosemount 702 Wireless Discrete Transmitter
Emerson Rosemount 702 Wireless Plunger Arrival Transmitter
Emerson Rosemount 705 Wireless Totalizing Transmitter
Emerson Rosemount 802 Wireless Discrete Transmitter
Emerson Rosemount 4390 Series of Corrosion and Erosion Wireless Transmitter
Emerson Rosemount 3051C Coplanar Pressure Transmitters
Emerson Rosemount™ 2051CFP Wireless Integral Orifice Flow Meter