Power Engineering 
K-JIANG
NameDescriptionContent
  • GE IS420ESWAH5A Mark VIe IONet Switch
  • GE IS420ESWAH4A Mark VIe IONet Switch
  • GE IS420ESWAH2A Mark VIe IONet Switch
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Triconex Tricon Safety Instrumented System (SIL3)
  • TMEIC Momentary Voltage Dip Multiple Power Compensator
  • TMEIC 21 G Series three-phase high-voltage motors deliver
  • TMEIC TM-AC Series 800 Frame
  • TMEIC Custom-Designed Induction Motors
  • TMEIC 21-L Series Medium Voltage Induction Motors
  • TMEIC 21-H Series three-phase high-voltage motors deliver
  • TMEIC 21-FII Series three-phase high-voltage motors
  • TMEIC 21-VLL Series Vertical Motors
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
Current Location:

E-mail

Password

Register Forgot password?
531X126SNDAFG1 | General Electric Snubber Board
❤ Add to collection

531X126SNDAFG1 | General Electric Snubber Board

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
531X126SNDAFG1 | General Electric Snubber Board
U.S.$10359.00
U.S.$6881.00
Weight:2.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
531X126SNDAFG1 | General Electric Snubber Board

Product Description P/N: 531X126SNDAFG1 DESCRIPTION / SPECIFICATIONS Description The GE 531X126SNDAFG1 Snubber Board is designed to protect industrial control circuits from harmful voltage spikes and transients. By absorbing and dissipating excess energy, it ensures stable operation and extends the lifespan of critical components, enhancing the reliability and durability of automation systems. Technical Specifications Condition New / Never Used Surplus Brand General Electric Category PLCs/Machine Control Part Number 531X126SNDAFG1 Subcategory PC Board PLC/Add-On Board Function Snubber Card Series Drive Control Operating temperature -25 to 65 潞C Power Supply Voltage 125 V dc Board Size 33.0 cm high x 17.8 cm Information About 531X126SNDAFG1 The General Electric 531X126SNDAFG1 Snubber Board is a specialized PC board designed to enhance the performance and longevity of drive control systems within industrial automation. As a critical component within the broader category of PLC (Programmable Logic Controller) and machine control systems, this snubber board plays a crucial role in suppressing voltage spikes and transient noise, which can otherwise lead to component stress, malfunction, or failure. This function is especially important in environments where electrical noise and fluctuations are prevalent, making the 531X126SNDAFG1 a key asset in ensuring the reliability and stability of industrial operations. The primary function of the 531X126SNDAFG1 Snubber Board is to protect sensitive electronic components by absorbing and dissipating the excess energy generated by sudden voltage spikes. These spikes, often caused by inductive loads, switching operations, or other transient events, can introduce high voltage surges into the system, potentially damaging the circuitry. The snubber board mitigates these risks by providing a controlled path for the excess energy, thus reducing the stress on the system and preventing potential damage. This not only enhances the durability of the drive control system but also contributes to smoother and more consistent operation. Designed to operate within the stringent conditions of industrial environments, the 531X126SNDAFG1 is built to withstand operating temperatures ranging from -25 to 65 degrees Celsius. This wide temperature range ensures that the board can perform reliably even in extreme conditions, whether in high-temperature manufacturing settings or colder storage and operational environments. The board's robust construction is further complemented by its ability to function at a power supply voltage of 125 V DC, making it compatible with a variety of industrial power systems. Physically, the 531X126SNDAFG1 measures 33.0 cm in height and 17.8 cm in width, making it a substantial component within the drive control system. Its size is indicative of the complex and robust circuitry required to effectively manage and dissipate the energy from voltage spikes. Despite its larger footprint, the board is designed for integration into existing systems with minimal disruption, allowing for straightforward installation and maintenance. This ease of integration is a significant advantage in industrial settings, where downtime can be costly and efficiency is paramount. The 531X126SNDAFG1 is part of General Electric's Drive Control series, a line of products known for their reliability and performance in controlling and protecting drive systems. As an add-on board, it can be incorporated into existing PLC systems to enhance their capabilities, providing an additional layer of protection against electrical disturbances. This makes the snubber board particularly valuable in applications where the integrity of the drive system is critical, such as in manufacturing plants, power generation facilities, and other industrial environments where high-performance control systems are essential. One of the key benefits of the 531X126SNDAFG1 Snubber Board is its ability to extend the lifespan of other components within the drive control system. By reducing the occurrence and impact of voltage spikes, the board helps to prevent wear and tear on sensitive components, thereby reducing the frequency of repairs and replacements. This not only lowers maintenance costs but also improves the overall reliability and uptime of the system. For industries where continuous operation is crucial, this added reliability can translate into significant operational efficiencies and cost savings. In addition to its protective capabilities, the 531X126SNDAFG1 is also designed with safety in mind. The suppression of voltage spikes reduces the risk of electrical faults that could lead to hazardous conditions, such as overheating or electrical fires. This makes the snubber board an important component in ensuring the safety of both the equipment and the personnel operating it. Overall, the General Electric 531X126SNDAFG1 Snubber Board is a vital component for drive control systems in industrial settings. Its robust design, wide operating temperature range, and ability to manage high voltage levels make it an essential tool for protecting and extending the life of sensitive electronic components. Whether used in manufacturing, power generation, or other industrial applications, the 531X126SNDAFG1 provides reliable performance and enhances the overall stability and safety of drive control systems. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • Triconex Tricon Safety Instrumented System (SIL3)
  • TMEIC Momentary Voltage Dip Multiple Power Compensator
  • TMEIC 21 G Series three-phase high-voltage motors deliver
  • TMEIC TM-AC Series 800 Frame
  • TMEIC Custom-Designed Induction Motors
  • TMEIC 21-L Series Medium Voltage Induction Motors
  • TMEIC 21-H Series three-phase high-voltage motors deliver
  • TMEIC 21-FII Series three-phase high-voltage motors
  • TMEIC 21-VLL Series Vertical Motors
  • GE Mark* VIe Industrial Ethernet / IONet Switches Summary Sheet
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0124 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521-0025 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A, ground switching
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A, timestamping
  • SAACKE ATONOX THE ULTRA-LOW-NOX BURNER FOR YOUR LARGE-SCALE COMBUSTION
  • SAACKE Pulverized fuels.
  • SAACKE SPECIAL GASES.
  • SAACKE Special liquid fuels
  • SAACKE BIOFUELS. Biogenic fuels
  • SAACKE IGNITION AND SUPPORT BURNERS.
  • SAACKE WATER TUBE BOILERS.
  • SAACKE Thermal processing systems
  • SAACKE MODERN LOW-NOX BURNERS FOR ALMOST ANY FUEL
  • SAACKE GreenDock ZERO EMISSION ENERGY IN PORT.
  • SAACKE WASTE HEAT RECOVERY UNIT.
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?