The PlantPAx® 5.0 distributed control system (DCS) introduces new process functionality native to controllers,
cyber-secured architectures, and improved system availability and workflows.
These benefits help reduce the complexity of traditional DCS and overall costs
at all phases of the plant lifecycle for hybrid and Process industries.
Accelerate your digital transformation with our latest PlantPAx® 5.0 DCS version and unlock
more opportunities with our ControlLogix® 5580 and CompactLogix™ 5380 Process controllers.

Restrictions
• Volts per Hertz operation requires the use of the Custom User Defined Controller Communication Format.
If another Controller Communication Format is selected (e.g. Velocity Control,
Position Control or User Defined Control) and the drive is configured for Volts per Hertz operation,
the Drive Module will not connect to the controller.
• This module sometimes experiences PMI Comm faults during power cycles.
For example, when the Drive Module and PMI processor are power-cycled the drive module initializes its interface
with the PMI processor. During the transition from initialization to synchronized communication,
the Drive Module sometimes experiences communication faults and warnings.
General
The power converter modules DCS800-S have the protection class IP00 and are to be mounted in a cubicle or finger protected area.
There are different sizes (D1. D2. D3. D4. D5. D6. D7), graduated in terms of current and voltage ranges.
All units are equipped with the DCS800 Control Panel.
It can be snapped into place on the power converter module or installed in the switchgear cubicle door by means of amounting kit.
Accessories such as external fuses, line reactors etc. are also available, to complete the drive system.
All converter modules up to 525 V and 1000 A (D1...D4) are equipped with field exciters.
The power section of the converters is available as single (2-Q) bridge or double (4-Q) bridge.
4-Q drives are required for regenerative breaking.
4-Q drives can be built by:
–Double (4-Q) armature bridge or –Single (2-Q) armature bridge plus a double (4-Q) field converter bridge
The bridge type has an influence on the maximum output voltage of the converter. See table below.

A-B 1769-L16ER-BB1B CompactLogix 5370 L1 Controller |
A-B 1769-L18ER-BB1B CompactLogix 5370 L1 Controller |
A-B 1769-L18ERM-BB1B CompactLogix 5370 L1 Controller |
A-B 1769-L18ERM-BB1BK CompactLogix 5370 L1 Controller |
A-B 1769-L19ER-BB1B CompactLogix 5370 L1 Controller |
A-B 1769-L19ER-BB1BK CompactLogix 5370 L1 Controller |
A-B 1769-L24ER-QB1B CompactLogix 5370 L2 Controller |
A-B 1769-L24ER-QBFC1B CompactLogix 5370 L2 Controller |
A-B 1769-L24ER-QBFC1BK CompactLogix 5370 L2 Controller |
A-B 1769-L27ERM-QBFC1B CompactLogix 5370 L2 Controller |
A-B 1769-L30ER CompactLogix 5370 L3 Controllers |
A-B 1769-L30ERK CompactLogix 5370 L3 Controllers |
A-B 1769-L30ERM CompactLogix 5370 L3 Controllers |
A-B 1769-L30ERMK CompactLogix 5370 L3 Controllers |
A-B 1769-L30ERMS CompactLogix 5370 L3 Controllers |
A-B 1769-L30ER-NSE CompactLogix 5370 L3 Controller |
A-B 1769-L32E EtherNet Processor |
A-B 1769-L32EK EtherNet Processor |
A-B 1769-L33ER CompactLogix 5370 L3 Controllers |
A-B 1769-L33ERK Dual Ethernet w/DLR capability |
A-B 1769-L33ERM CompactLogix 5370 L3 Controllers |
A-B 1769-L33ERMK Dual Ethernet w/DLR capability |
A-B 1769-L33ERMO Armor CompactLogix 5370 On Machine Controller |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved