Power Engineering 
K-JIANG
NameDescriptionContent
  • Eaton 1023843 Power Board B20098140711 A5
  • Eaton PDG23F0125VFFJ Power Defense molded case circuit breaker
  • Eaton 9130 1KVA Marine Filter Pn 1029424 Rev 002 220/230/240VAC 50/60Hz 1603
  • Eaton/Dynamatic 15-871-6 AF5000+ Power Supply Board P-CTR 158716
  • EATON D80JE22A PNEUMATIC TIMER SER.A2
  • Eaton MTL F892 8 Segment Redundant Fieldbus Power Supply for use with non-proprietary cabled systems
  • Eaton Power Xpert PXM 4000/6000/8000 Meter
  • Eaton PXM4051A1BB Power Xpert meter 4000
  • Eaton F810 Redundant fieldbus power for Foxboro I/A series™ control system
  • Eaton Power Xpert Meters PXM 4000/6000/8000
  • Woodward MFR-300 Multifunction Relay
  • Woodward Power Management Accessories
  • Eaton MTL RugiCAM-IP HD network camera
  • Woodward Engine Solutions
  • Woodward MicroNet XT – Control System
  • Moog J814 Series Pneumatic Servo Valves
  • Moog 79 Series (79-200) Servo Valves
  • MOOG 79 Series (79-100) Servo Valves
  • MOOG 78 series Moog family of Mechanical Feedback (MFB) Servo Valves
  • MOOG 771, 772, 773 Series Servo Valves
  • MOOG 761 Series Flow Control Servo Valves
  • MOOG 744 Series Servo Valves
  • MOOG 743 Series Servo Valves
  • MOOG 730 Series Servo Valves
  • Aerotech SM Series High-Performance Stepper Motors
  • Aerotech BLMSC Series Linear Motors
  • Aerotech Custom Rotary Motors
  • Aerotech Custom Linear Motors
  • Aerotech BMS Series Brushless, Slotless Rotary Motors
  • Aerotech BM Series Brushless Rotary Motors
  • Basler Electric SSR 125-12 SSR Series Voltage Regulator
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current, 0/4…20 mA
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input,IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC OXITEC® 5000+ O₂ Analyzer System
  • ENOTEC CEMTEC® hot/wet Only CEMTEC guarantees 95 % availability of kiln gas values
  • ENOTEC AQUATEC® 1000 Safe and robust O₂ & H₂O measurement directly in the drying process
  • ENOTEC ENSITU® 7000 The compact O₂ analyzer with integrated electronics
  • ENOTEC CEMTEC® Reliable and maintenance-free gas extraction system for extreme combustion processes
  • ENOTEC SILOTEC® 8000 Fast, reliable and safe silo monitoring for smoldering fire detection
  • ENOTEC COMTEC® 6000 StaubEx The robust O₂ & COe analyzer for measurements in ATEX Zone 21/22
  • ENOTEC COMTEC® 6000 GasEx The robust O₂ & COe analyzer for measurements in ATEX Zone 1/2
  • ENOTEC COMTEC® 6000 The fast and reliable in-situ O₂ & COe analyzer
  • ENOTEC OXITEC® 500E The long-lasting O₂ analyzer in 19" format
  • ENOTEC OXITEC® 5000 GasEx The robust O₂ analyzer for measurements in ATEX Zone 1/2
  • MOOG 728 Series Servo Valves
  • MOOG 631 Series Servo Valves
  • MOOG 32 SERIES MICRO SERVO VALVES
  • MOOG 31 Series Servo Valves
  • MOOG 30 Series Servo Valves
  • MOOG DIN Rail Modules - Analog Control Cards
  • MOOG 72 Series Flow Control Servo Valves
  • Kongsberg MRU S Motion Reference Unit (MRU) designed for fish-finding sonars and echo sounders
  • Kongsberg MRU 3 Motion Reference Unit
  • Kongsberg MRU H Motion Reference Unit
  • Kongsberg MRU E The extended temperature motion sensor
  • Kongsberg MGC R1 Compass Gyro Compass
  • Kongsberg MGC® COMPAS R-series
  • Kongsberg MGC® Gyro Compass System Software defined switchover solution
  • Kongsberg AVR 100 Helideck audio and video recorder
  • Kongsberg HMS 300 Helideck Monitoring System
  • Aerotech S Series Brushless, Frameless Torque Motors
  • Aerotech BLMX Series Linear Motors
  • Aerotech BLMH Series Linear Motors
  • Aerotech BLM Series Linear Motors
  • Aerotech BLMC Series Linear Motors
  • Aerotech BLMUC Series Linear Motors
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel Isolated RTD Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2554-A 4-Channel High-Speed Counter Input Module
  • CTI 2505 Vibration Sensor Interface Module
  • CTI SIMATIC 505 Ethernet OPC Server
  • CTI 2500-OPC KEPServerEX OPC and Communications Server
  • CTI 2572-DDS2 I/O Server
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature
  • LENZE SMVector IP65 frequency inverter
  • LENZE SMVector IP31 frequency inverter
  • LENZE 8400 motec frequency inverter
  • LENZE i650 motec decentralized variable frequency drive
Current Location:

E-mail

Password

Register Forgot password?
GE IS220PTCCH1A IO PACK, THERMOCOUPLE
❤ Add to collection

GE IS220PTCCH1A IO PACK, THERMOCOUPLE

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
IS220PTCCH1A
U.S.$10055.00
U.S.$4548.00
Weight:0.000KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
IS220PTCCH1A

Part Number IS220PTCCH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PTCCH1A is a thermocouple input module developed by General Electric. It serves as a bridge, connecting I/O Ethernet networks to a thermocouple input terminal board through a sophisticated electrical interface. Thermocouple Input Module is a sophisticated and versatile component of the Mark VIe series, designed to provide precise temperature monitoring in a wide range of industrial applications. Its compatibility with various thermocouple types, scalability in handling inputs, and user-friendly features make it a valuable asset in control and monitoring systems where temperature control and measurement are paramount. Features At the core of the module is a processor board that is common to all Mark VIe distributed I/O packs. This central processing unit acts as the brain of the module, orchestrating data acquisition and communication. It forms the foundation upon which the module's functionality is built. To cater to the precise requirements of thermocouple inputs, the module is equipped with a thermocouple input-specific acquisition board. This dedicated hardware ensures accurate and reliable measurement of temperature variations, essential for applications where temperature control is critical.

The module boasts impressive scalability, offering flexibility in handling thermocouple inputs. In a Simplex setup with the TBTCH1B terminal board, each module can manage up to 12 thermocouple inputs. When two modules are employed in conjunction, this configuration allows for the monitoring of a total of 24 inputs. Accommodates various thermocouple types, including E, J, K, S, and T thermocouples, as well as mV inputs. It encompasses a broad mV input range from -8 mV to +45 mV, ensuring compatibility with a wide array of temperature measurement devices. To power the module, it features dual RJ45 Ethernet ports and a three-pin power input, simplifying power connection and providing redundancy for reliable operation. The module's output interface is a DC-37 pin connector that directly interfaces with the terminal board connector, enabling a secure and efficient connection. For real-time status monitoring and diagnostics, the module incorporates indicator LEDs. These LEDs provide visual feedback, allowing operators to assess the module's operational status and swiftly identify any potential issues. Compatibility Dual RJ45 Ethernet ports and three-pin power input are used to power the pack. The output is a DC-37 pin connector that connects directly to the terminal board connector. Indicator LEDs are used to display visual diagnostics. It accepts E, J, K, S, and T thermocouples as well as mV inputs. IS220PTCCH1A Installation Secure the Terminal Board: Begin by selecting the terminal board that is suitable for your application. The terminal board provides the interface between the I/O pack and your system. Ensure that it is securely mounted and positioned as needed for your specific setup. Connect the PTCC I/O Pack: Connect the I/O to the terminal board connectors directly. This step establishes the electrical connection between the I/O pack and your system. Make sure the connections are secure to prevent any loose or intermittent contact issues. Mechanical Securing of Packs: To physically secure the I/O in place, use the threaded studs located close to the Ethernet ports. This step ensures that the I/O pack remains firmly attached to the terminal board and prevents any unintentional disconnection due to vibrations or movement. Ethernet Connections: Depending on your system configuration and networking requirements, you may need to connect one or two Ethernet wires to the I/O pack. You have the flexibility to use either port for network connectivity. If you opt for dual connections, make sure to connect ENET1 to the network linked with the R controller for proper network communication. Power Connection: Connect the I/O pack to the power source by plugging in the connector on the side of the pack. It is important to note that the I/O pack incorporates an inbuilt soft-start feature. This feature regulates the current inrush when power is applied, eliminating the need to disconnect the connection before plugging it in. This simplifies the power connection process while maintaining system stability. Configuration with ToolboxST Application: Once the I/O pack is physically installed and connected, the final step involves configuring the pack as needed for your application. This can be accomplished using the ToolboxST application, which provides a user-friendly interface for configuring and customizing the I/O pack's settings to meet your specific requirements. Operation Processor The processor board is connected to an acquisition board that is appropriate to the purpose of the I/O pack or module. The soft-start circuit ramps up the voltage available on the processor board when input power is applied. The processor reset is removed, and the local power supplies are sequenced on. The CPU runs self-test procedures before loading application code from flash memory that is particular to the I/O pack or module type. To verify that the application code, acquisition board, and terminal board are all correctly matched, the application code reads board ID information. Auto-Reconfiguration The Auto-Reconfiguration capability enables the operator to swap I/O packs without having to manually reconfigure each pack or module. When the Auto-Reconfiguration functionality is activated, a reconfiguration file is automatically downloaded from the controller to the I/O pack when the controller detects an I/O pack booting with a different configuration. Analog Input Hardware The thermocouples linked to the terminal board send 12 signals at mV levels to the PTCC input board. Six differential multiplexers, the main multiplexer, and a 16-bit analog to digital converter deliver the digital data to the next processor board make up the analog input portion. Diagnostics The following self-diagnostic tests are carried out by the pack: Power-Up Self-Test: Upon powering up, the pack initiates a comprehensive self-test. This test encompasses an array of critical hardware components, including RAM (Random Access Memory), flash memory, Ethernet ports, and the processor board. By examining these components, the pack can promptly detect any issues or discrepancies that might hinder its performance. Power Supply Monitoring: The pack maintains constant vigilance over its internal power supply. It continually monitors power levels to ensure that the device is receiving the requisite voltage and current to operate optimally. This proactive monitoring safeguards against power-related failures or disruptions. Electronic ID Verification: To confirm the integrity of the hardware setup, the pack verifies the electronic identification information of the terminal board, acquisition board, and processor board. This verification process ensures that the hardware components are consistent and that no unauthorized changes or replacements have occurred. Relay Drive Validation: The pack performs a thorough check of the commanded state of each relay drive and cross-references it with the feedback received from the command output circuit. This cross-validation is critical for verifying that the relays are operating as expected, preventing potential issues caused by relay malfunction. Relay Board Feedback Processing: The pack reads and processes feedback specific to the relay boards. This step is instrumental in evaluating the performance of relay boards and identifying any irregularities or issues that may need attention or maintenance. Multicast Communications Monitoring: When configured with a PGEN pack, the system continuously monitors multicast communications. This real-time monitoring ensures the integrity and effectiveness of the communication system, helping to detect any anomalies, delays, or disruptions in the transmission of data.

  • Eaton MTL F892 8 Segment Redundant Fieldbus Power Supply for use with non-proprietary cabled systems
  • Eaton Power Xpert PXM 4000/6000/8000 Meter
  • Eaton PXM4051A1BB Power Xpert meter 4000
  • Eaton F810 Redundant fieldbus power for Foxboro I/A series™ control system
  • Eaton Power Xpert Meters PXM 4000/6000/8000
  • Woodward MFR-300 Multifunction Relay
  • Woodward Power Management Accessories
  • Eaton MTL RugiCAM-IP HD network camera
  • Woodward Engine Solutions
  • Woodward MicroNet XT – Control System
  • Moog J814 Series Pneumatic Servo Valves
  • Moog 79 Series (79-200) Servo Valves
  • MOOG 79 Series (79-100) Servo Valves
  • MOOG 78 series Moog family of Mechanical Feedback (MFB) Servo Valves
  • MOOG 771, 772, 773 Series Servo Valves
  • MOOG 761 Series Flow Control Servo Valves
  • MOOG 744 Series Servo Valves
  • MOOG 743 Series Servo Valves
  • MOOG 730 Series Servo Valves
  • Aerotech SM Series High-Performance Stepper Motors
  • Aerotech BLMSC Series Linear Motors
  • Aerotech Custom Rotary Motors
  • Aerotech Custom Linear Motors
  • Aerotech BMS Series Brushless, Slotless Rotary Motors
  • Aerotech BM Series Brushless Rotary Motors
  • Basler Electric SSR 125-12 SSR Series Voltage Regulator
  • Beckhoff ELX3158 | EtherCAT Terminal, 8-channel analog input, current
  • Beckhoff ELX3152-0090 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELX3152 | EtherCAT Terminal, 2-channel analog input, current, 0/4…20 mA
  • Beckhoff ELM3704-1001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0020 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0001 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3704-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckhoff ELM3702-0101 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3702-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3604-0002 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3604-0000 | EtherCAT Terminal, 4-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0032 | EtherCAT Terminal, 2-channel analog input,IEPE/accelerometer
  • Beckhoff ELM3602-0030 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0002 | EtherCAT Terminal, 2-channel analog input, IEPE/accelerometer
  • Beckhoff ELM3602-0000 | EtherCAT Terminal, 2-channel analog input
  • Beckhoff ELM3544-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3542-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • ENOTEC OXITEC® 5000+ O₂ Analyzer System
  • ENOTEC CEMTEC® hot/wet Only CEMTEC guarantees 95 % availability of kiln gas values
  • ENOTEC AQUATEC® 1000 Safe and robust O₂ & H₂O measurement directly in the drying process
  • ENOTEC ENSITU® 7000 The compact O₂ analyzer with integrated electronics
  • ENOTEC CEMTEC® Reliable and maintenance-free gas extraction system for extreme combustion processes
  • ENOTEC SILOTEC® 8000 Fast, reliable and safe silo monitoring for smoldering fire detection
  • ENOTEC COMTEC® 6000 StaubEx The robust O₂ & COe analyzer for measurements in ATEX Zone 21/22
  • ENOTEC COMTEC® 6000 GasEx The robust O₂ & COe analyzer for measurements in ATEX Zone 1/2
  • ENOTEC COMTEC® 6000 The fast and reliable in-situ O₂ & COe analyzer
  • ENOTEC OXITEC® 500E The long-lasting O₂ analyzer in 19" format
  • ENOTEC OXITEC® 5000 GasEx The robust O₂ analyzer for measurements in ATEX Zone 1/2
  • MOOG 728 Series Servo Valves
  • MOOG 631 Series Servo Valves
  • MOOG 32 SERIES MICRO SERVO VALVES
  • MOOG 31 Series Servo Valves
  • MOOG 30 Series Servo Valves
  • MOOG DIN Rail Modules - Analog Control Cards
  • MOOG 72 Series Flow Control Servo Valves
  • Kongsberg MRU S Motion Reference Unit (MRU) designed for fish-finding sonars and echo sounders
  • Kongsberg MRU 3 Motion Reference Unit
  • Kongsberg MRU H Motion Reference Unit
  • Kongsberg MRU E The extended temperature motion sensor
  • Kongsberg MGC R1 Compass Gyro Compass
  • Kongsberg MGC® COMPAS R-series
  • Kongsberg MGC® Gyro Compass System Software defined switchover solution
  • Kongsberg AVR 100 Helideck audio and video recorder
  • Kongsberg HMS 300 Helideck Monitoring System
  • Aerotech S Series Brushless, Frameless Torque Motors
  • Aerotech BLMX Series Linear Motors
  • Aerotech BLMH Series Linear Motors
  • Aerotech BLM Series Linear Motors
  • Aerotech BLMC Series Linear Motors
  • Aerotech BLMUC Series Linear Motors
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel Isolated RTD Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2554-A 4-Channel High-Speed Counter Input Module
  • CTI 2505 Vibration Sensor Interface Module
  • CTI SIMATIC 505 Ethernet OPC Server
  • CTI 2500-OPC KEPServerEX OPC and Communications Server
  • CTI 2572-DDS2 I/O Server
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 8DIO / 2UAI (MATURE)
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485, 900MHz, 4DI / 4DO / 2UAI / 2AO
  • Beckhoff ELM3504-0030 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3504-0000 | EtherCAT Terminal, 4-channel analog input, measuring bridge
  • Beckhoff ELM3502-0030 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3502-0000 | EtherCAT Terminal, 2-channel analog input, measuring bridge
  • Beckhoff ELM3348-0033 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0030 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3348-0003 | EtherCAT Terminal, 8-channel analog input, temperature
  • LENZE SMVector IP65 frequency inverter
  • LENZE SMVector IP31 frequency inverter
  • LENZE 8400 motec frequency inverter
  • LENZE i650 motec decentralized variable frequency drive
  • LENZE i550 motec decentralized variable frequency drive
  • LENZE 8400 protec frequency inverter
  • LENZE i510 protec frequency inverter
  • LENZE i550 cabinet frequency inverter
  • LENZE i510 cabinet frequency inverter
  • LENZE Cabinet PC series Industrial PCs
  • LENZE Embedded Line series Industrial PCs
  • LENZE Command Station series Industrial PCs
  • LENZE 3200 C Controller
  • Eaton 5073E-T 7-Port + 3-Combo Port Gigabit Managed Ethernet Switch
  • Aerotech Automation1 FLEX Distributed Amplifier Multi-Axis Servo Control System
  • Aerotech Automation1 HXA4 6-Axis Hexapod Servo Drive
  • Aerotech Automation1 iHXA4 6-Axis Hexapod Servo Drive with Motion Controller
  • Aerotech TM Series Transformers
  • Aerotech MFM Motor Filter Module
  • Aerotech MPG Handwheel Pendant
  • Aerotech ETM Enhanced Throughput Module
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?