Power Engineering 
K-JIANG
NameDescriptionContent
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3401 Load Shedding Relay
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-7679 R-PAC
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3311A Transformer Protection (2, 3, or 4-Winding) Relay
  • Beckwith Electric B-6200A-U1 Hinge Kit
  • Beckwith Electric M-2032B Battery Charger/Power Supply
  • Beckwith Electric M-2900A Tapchanger Control Cabinet
  • Beckwith Electric M-6200A Digital Voltage Regulator Control
  • Beckwith Electric B-2048 Resistor Assembly
  • Beckwith Electric M-0121 and M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0404 Voltage Isolation Transformer
  • Beckwith Electric M-0329B LTC Backup Control
  • Beckwith Electric M-0001 Battery Transient Suppressor
  • Beckwith Electric Module d’Équilibrage en Parallèle M-0115A
  • Beckwith Electric M-0115A Parallel Balancing Module
  • Beckwith Electric M-2025D Current Loop Interface Module
  • Beckwith Electric M-0362 Voltage Isolation Transformer
  • Beckwith Electric M-2025B Current Loop Interface Module
  • Beckwith Electric M-2174B Adapter Panel
  • Beckwith Electric M-2027 AC to DC Backup Power Supply
  • Beckwith Electric M-2054 Surface Mount Kit
  • Beckwith Electric M-2067B Adapter Panel
  • Beckwith Electric M-2270B Adapter Panel
  • Beckwith Electric M-2050 Surface Mounting Kit
  • Beckwith Electric M-2230 Adapter Panel
  • Beckwith Electric M-2051 and M-2052 Connection Harness
  • Beckwith Electric M-2279D Adapter Panel
  • Beckwith Electric M-2053 Adapter Panel
  • Beckwith Electric M-2302 Adapter Panel
  • Beckwith Electric M-2220 Adapter Panel
  • Beckwith Electric M-2901 Surface Mounting Kit
  • Beckwith Electric M-2280B Adapter Panel
  • Beckwith Electric M-2354C Adapter Panel
  • Beckwith Electric M-2379 Adapter Panel
  • Beckwith Electric M-2271B Adapter Panel
  • Beckwith Electric M-2168 Adapter Panel
  • Beckwith Electric M-2286 Adapter Panel
  • Beckwith Electric M-2026 AC to DC Backup Power Supply
  • Beckwith Electric M-2339 Adapter Panel
  • Beckwith Electric M-2948 Tap Position Sensor
  • Beckwith Electric M-3425A Comprehensive Generator Relay
  • GE Measurement & Control XAMP Preamplifer
  • Woodward LS 4 Circuit Breaker Control
  • Key Topics Covered in the Honeywell TDC 3000 Training Manual
  • Honeywell TDC 3000X Advanced Process Manager
  • Honeywell 8-Node Enhanced Micro TDC 3000
  • Honeywell Upgrade from TDC and TPS to Experion
  • Beckhoff ELM3142-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3104-0030 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0020 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0000 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3102-0120 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0100 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0030 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3102-0000 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3004-0030 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3004-0000 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3002-0425 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0405 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0325 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0305 | EtherCAT Terminal, 2-channel analog input, voltage
  • Bently Nevada 330500 Velomitor Piezo-velocity Sensor
  • Woodward DPC (P/N 5417-557 / P/N 8445-1024 / P/N 8445-1026) Direct Configuration Cable
  • Basler Electric 9488800100 AVC Sensing Module
  • Basler Electric AVC125-10 Voltage Regulator
  • Basler Electric BE3-37, BE3-51, and BE3-37/51 Ac Current Relay
  • Basler Electric AVC63-4, AVC63-4D, Voltage Regulator
  • Basler Electric MOC21XX through MOC24XX and MOC29XX Motor Operated Potentiometer
  • Basler Electric BE1-FLEX Protection, Automation, and Control System
  • Basler Electric EL 200 Minimum/Maximum Excitation Limiter
  • Basler Electric XR2002 and XR2002F PMG Voltage Regulator
  • Basler Electric DXCB-2 De-Excitation/Crowbar Module
  • Basler Electric EDM-200 Exciter Diode Monitor
  • Basler Electric CLASS 300 EQUIPMENT Electronic Manual Voltage Control MVC-300
  • Basler Electric Class 200 Equipment SSR Series Voltage Regulators
  • Basler Electric SSR 63-12NF SSR Series Voltage Regulators
  • Basler Electric Model RA-70 Microprocessor-Based Reference Adjuster
  • Beckhoff ELM3002-0235 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0225 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0030 | EtherCAT Terminal, 2-channel analog input, voltage
Current Location:

E-mail

Password

Register Forgot password?
GE IS200IVFBG1A BD,PWM-3 CURRETN FEEDBACK
❤ Add to collection

GE IS200IVFBG1A BD,PWM-3 CURRETN FEEDBACK

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
IS200IVFBG1A
U.S.$10055.00
U.S.$4548.00
Weight:0.000KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
IS200IVFBG1A

Part Number IS200IVFBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200IVFBG1A is a Current Feedback Board developed by GE. It is a part of EX2100 excitation system. The Current Feedback Board, developed by GE, plays a critical role within the excitation system, specifically in applications involving a 3-level pulse-width modulated (PWM) inverter. Positioned within the load cabinet of the series, this board is integral to ensuring precise current feedback control, thereby enhancing the overall efficiency and performance of the system. INSTALLATION AND INTEGRATION Phase Leg Assembly: The Phase Leg Assembly forms the fundamental structure responsible for managing electrical phases within the 3-level pulse-width modulated (PWM) inverter system. Comprising semiconductor devices arranged strategically, it controls the switching operations that regulate current flow and voltage output. The Current Feedback Board plays a critical role in this assembly by continuously monitoring and precisely adjusting current levels, ensuring efficient power conversion and optimal performance of the inverter system.

Back Base: Providing robust structural support and secure mounting points, the Back Base ensures the stability and proper alignment of various components within the load cabinet. It anchors the Current Feedback Board and other critical modules in place, safeguarding against vibrations and mechanical stresses that could affect operational reliability. This structural integrity is essential for maintaining consistent performance and facilitating ease of maintenance when necessary. Interface Module: The Interface Module acts as a pivotal intermediary within the excitation system, facilitating seamless communication and control interfaces between different system elements. It enables data exchange and synchronization between the Current Feedback Board, Phase Leg Assembly, and other subsystems. This coordination ensures cohesive operation and efficient management of system functions, enhancing overall reliability and responsiveness to operational demands. Capacitor Assembly Module: Central to energy storage and voltage stabilization, the Capacitor Assembly Module stores electrical energy and smoothens voltage levels within the inverter system. It absorbs transient currents and maintains stable voltage outputs, contributing to the system's reliability under varying load conditions.

The Current Feedback Board collaborates closely with this module to regulate current feedback accurately, supporting consistent power delivery and minimizing fluctuations that could impact system performance. Blower Assembly: Critical for thermal management, the Blower Assembly provides essential cooling to maintain optimal operating temperatures for components housed within the load cabinet. By regulating heat dissipation, it prevents overheating and ensures the longevity and reliability of sensitive electronic parts, including the Current Feedback Board. Effective cooling is essential for sustaining performance accuracy and operational efficiency under demanding industrial environments. Cable Assemblies: Interconnecting various subsystems and components, Cable Assemblies establish essential electrical pathways for power distribution and signal transmission within the load cabinet. They facilitate seamless integration and communication between the Current Feedback Board, Phase Leg Assembly, Interface Module, and other critical system elements. This interconnectedness ensures coordinated operation and efficient energy management throughout the excitation system. AC Buswork: As the primary conduit for distributing AC power, the AC Buswork ensures efficient and reliable power supply to all components within the excitation system. It distributes electrical energy from the source to different modules, including the Current Feedback Board, ensuring consistent and stable operation. The board integration with the AC Buswork is crucial for maintaining system integrity and optimizing performance, supporting continuous power generation processes without interruptions. SYSTEM SOFTWARE FEATURES The exciter system is designed with a high degree of flexibility and modularity, enabling it to be configured in various ways to suit different operational needs. This flexibility allows for a range of output currents and provides options for implementing different levels of redundancy within the system. Depending on the specific requirements of the application, operators can choose from configurations that include power from potential transformers connected to generator terminals, compound sources, or auxiliary sources via excitation transformers linked to auxiliary buses. These choices ensure that the exciter system can adapt seamlessly to different power distribution setups and operational scenarios.

Redundancy is a key feature of the exciter system, offering options such as single or multiple bridges, warm backup bridges, and simplex or redundant controls. These redundancy options are critical for enhancing system reliability and minimizing downtime. Single bridges provide basic functionality, while multiple bridges allow for increased capacity and reliability by distributing load across multiple units. Warm backup bridges ensure rapid failover in case of primary bridge failure, maintaining continuity of operation without significant interruption. Similarly, simplex or redundant controls provide flexibility in how control signals are managed, ensuring that even in the event of control system failure, backup mechanisms can seamlessly take over to maintain operation. Feedback mechanisms within the exciter system are essential for monitoring and controlling performance. Key inputs include feedback from generator line current and stator output voltage, which are used to regulate and adjust the excitation levels. By monitoring these parameters closely, the exciter system can optimize its outputs of DC voltage and current to the exciter field. This controlled output is crucial for adjusting the magnetic field strength within the generator, thereby influencing voltage regulation and overall power quality.TEL:+8618144100983

  • Beckhoff ELM3348-0000 | EtherCAT Terminal, 8-channel analog input, temperature
  • Beckhoff ELM3344-0033 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0030 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0003 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3344-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3246-0000 | EtherCAT Terminal, 6-channel analog input, temperature
  • Beckhoff ELM3244-0000 | EtherCAT Terminal, 4-channel analog input, temperature
  • Beckhoff ELM3148-0000 | EtherCAT Terminal, 8-channel analog input, multi-function
  • Beckhoff ELM3146-0000 | EtherCAT Terminal, 6-channel analog input
  • Beckhoff ELM3144-0000 | EtherCAT Terminal, 4-channel analog input, multi-function
  • Beckwith Electric M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System
  • Beckwith Electric M-4172 Digital Motor Bus Transfer System
  • Beckwith Electric M-3401 Load Shedding Relay
  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-7679 R-PAC
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3311A Transformer Protection (2, 3, or 4-Winding) Relay
  • Beckwith Electric B-6200A-U1 Hinge Kit
  • Beckwith Electric M-2032B Battery Charger/Power Supply
  • Beckwith Electric M-2900A Tapchanger Control Cabinet
  • Beckwith Electric M-6200A Digital Voltage Regulator Control
  • Beckwith Electric B-2048 Resistor Assembly
  • Beckwith Electric M-0121 and M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0404 Voltage Isolation Transformer
  • Beckwith Electric M-0329B LTC Backup Control
  • Beckwith Electric M-0001 Battery Transient Suppressor
  • Beckwith Electric Module d’Équilibrage en Parallèle M-0115A
  • Beckwith Electric M-0115A Parallel Balancing Module
  • Beckwith Electric M-2025D Current Loop Interface Module
  • Beckwith Electric M-0362 Voltage Isolation Transformer
  • Beckwith Electric M-2025B Current Loop Interface Module
  • Beckwith Electric M-2174B Adapter Panel
  • Beckwith Electric M-2027 AC to DC Backup Power Supply
  • Beckwith Electric M-2054 Surface Mount Kit
  • Beckwith Electric M-2067B Adapter Panel
  • Beckwith Electric M-2270B Adapter Panel
  • Beckwith Electric M-2050 Surface Mounting Kit
  • Beckwith Electric M-2230 Adapter Panel
  • Beckwith Electric M-2051 and M-2052 Connection Harness
  • Beckwith Electric M-2279D Adapter Panel
  • Beckwith Electric M-2053 Adapter Panel
  • Beckwith Electric M-2302 Adapter Panel
  • Beckwith Electric M-2220 Adapter Panel
  • Beckwith Electric M-2901 Surface Mounting Kit
  • Beckwith Electric M-2280B Adapter Panel
  • Beckwith Electric M-2354C Adapter Panel
  • Beckwith Electric M-2379 Adapter Panel
  • Beckwith Electric M-2271B Adapter Panel
  • Beckwith Electric M-2168 Adapter Panel
  • Beckwith Electric M-2286 Adapter Panel
  • Beckwith Electric M-2026 AC to DC Backup Power Supply
  • Beckwith Electric M-2339 Adapter Panel
  • Beckwith Electric M-2948 Tap Position Sensor
  • Beckwith Electric M-3425A Comprehensive Generator Relay
  • GE Measurement & Control XAMP Preamplifer
  • Woodward LS 4 Circuit Breaker Control
  • Key Topics Covered in the Honeywell TDC 3000 Training Manual
  • Honeywell TDC 3000X Advanced Process Manager
  • Honeywell 8-Node Enhanced Micro TDC 3000
  • Honeywell Upgrade from TDC and TPS to Experion
  • Beckhoff ELM3142-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3104-0030 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0020 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0000 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3102-0120 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0100 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0030 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3102-0000 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3004-0030 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3004-0000 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3002-0425 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0405 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0325 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0305 | EtherCAT Terminal, 2-channel analog input, voltage
  • Bently Nevada 330500 Velomitor Piezo-velocity Sensor
  • Woodward DPC (P/N 5417-557 / P/N 8445-1024 / P/N 8445-1026) Direct Configuration Cable
  • Basler Electric 9488800100 AVC Sensing Module
  • Basler Electric AVC125-10 Voltage Regulator
  • Basler Electric BE3-37, BE3-51, and BE3-37/51 Ac Current Relay
  • Basler Electric AVC63-4, AVC63-4D, Voltage Regulator
  • Basler Electric MOC21XX through MOC24XX and MOC29XX Motor Operated Potentiometer
  • Basler Electric BE1-FLEX Protection, Automation, and Control System
  • Basler Electric EL 200 Minimum/Maximum Excitation Limiter
  • Basler Electric XR2002 and XR2002F PMG Voltage Regulator
  • Basler Electric DXCB-2 De-Excitation/Crowbar Module
  • Basler Electric EDM-200 Exciter Diode Monitor
  • Basler Electric CLASS 300 EQUIPMENT Electronic Manual Voltage Control MVC-300
  • Basler Electric Class 200 Equipment SSR Series Voltage Regulators
  • Basler Electric SSR 63-12NF SSR Series Voltage Regulators
  • Basler Electric Model RA-70 Microprocessor-Based Reference Adjuster
  • Beckhoff ELM3002-0235 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0225 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0030 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0000 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3783-0100 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3783 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3773 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3751-0024 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3751-0020 | EtherCAT Terminal, 1-channel analog input, multi-function
  • Beckhoff EL3751 | EtherCAT Terminal, 1-channel analog input, multi-function
  • Beckhoff EL3742 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff EL3702-0015 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3702 | EtherCAT Terminal, 2-channel analog input, voltage
  • CTI 2500S-27-1550 Slice I/O, RS232/485, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1550 Slice I/O, RS232/485, 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller (MATURE - replaced by 2500-RIO-B)
  • CTI 2532 16-Point Form-A Relay Output Module
  • Aerotech Automation1 XL4s High-Speed, Single-Phase Linear Servo Drive
  • Aerotech Automation1 XL2e Enhanced, Compact Linear Servo Drive
  • Aerotech Automation1 iXL2e Enhanced, Compact Linear Servo Drive with Motion Controller
  • Aerotech Automation1 XL5e Enhanced, Linear Servo Drive
  • Aerotech Automation1 GI4 Laser Scan Head Controller
  • Aerotech Automation1 SI4 Stepper Interface
  • Basler Electric BE3-GPR Generator Protective Relay
  • Basler Electric BE3-47N and BE3-47N/27 Phase Balance Relay
  • Basler Electric BE3-27T, BE3-59T, and BE3-27T/59T Ac Voltage Relay
  • Basler Electric BE1-CDS240 Current Differential System
  • Basler Electric BE3-49R - 3 Inputs Temperature Relay
  • Basler Electric SCP 250 Var/Power Factor Controller
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?