Each COM module forms a functional unit with the X-CB 001 02 connector board. Note that the
connector board must be separately purchased.
The fieldbus submodules are optional and must be mounted by the manufacturer. The fieldbus
submodule is selected when ordering the controller using the part number. Additionally, the
protocols used must be activated.

Scope of Delivery
The module must be installed on a suitable connector board to be able to operate. If a FTA
is used, a system cable is required to connect the connector board to the FTA. Connector
boards, system cables and FTAs are not included within the scope of delivery.
The connector boards are described in Chapter 3.6. the system cables are described in
Chapter 3.7. The FTAs are described in own manuals.
The new central modules support the various I/O modules of the previous generation.
The combination of the reliable HIQuad I/O modules and the new central module
has been named HIQuad X. This guarantees maximum compatibility for field installation.
This guarantees maximum compatibility and minimum modernisation effort in field installations.
As HIQuad X is now available, the H41q/H51q central modules have entered
the replacement phase of the HIMA product life cycle.
The H41q/H51q central modules will move to the legacy phase in 2020.
The legacy phase is expected to last 10 years and will be fully serviced.
The I/O levels will remain unchanged and will continue to be used in HIQuad X.
HIQuad X completes our intelligent security platform.
Safety Function
The module evaluates the digital input signals and provides them to the user program.
The safety function is performed in accordance with SIL 3.
Reaction in the Event of a Fault
If a fault occurs, the module adopts the safe state and the assigned input variables transmit
the initial value (default value = 0) to the user program.
The initial values must be set to 0 to ensure that the input variables transmit the value 0 to
the user program if a fault occurs.
The module activates the Error LED on the front plate.
Safety Power Supply Accessory Module HIMA 90100
22 120 Industrial Safety Output Controller HIMA
HIMA 22 100 Industrial Output Module for Safety Systems
Industrial Output Module with Isolation HIMA 80 106
2-Fold Analogue Limit Monitor Module HIMA 62 100
52 100 by HIMA Logic Module with Protective Coating
HIMA 42 400 Logic Function Module with Direct/Inverted Output
42 300 by HIMA Industrial Logic Control Module
HIMA F7533 Safety Module
HIMA 42 100 Logical Function Module for Safety Systems
Industrial Relay Amplifier Board 32 100 by HIMA
HIMA F 7508 PLC Bypass Module for Safety Systems
H 4137 by HIMA Industrial Relay Control Module
F35 011 Industrial Safety Controller Board HIMA
Safety Relay Module for Automation HIMA VR-H 4116
HIMA 80 105 Industrial Communication Module
42 110 by HIMA Industrial Logic Control Module
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved