Optimized control of proportional valves with PWM
The EL2535-xxxx output terminals are specially designed for the precise
control of single and double-coil proportional valves and proportional
solenoid valves. They regulate the output current through pulse width
modulation (PWM) of the supply voltage and are electrically isolated
from the E-bus. The current values (0 to maximum output current)
are specified by the automation device through a 16-bit value.
The output stages are protected against overload and short circuit.

Each EtherCAT pulse width current terminal contains two channels
whose signal state is indicated by LEDs. The light emitting diodes
simplify local diagnosis by displaying typical load and wiring faults.
A practical test was able to show that an EL2622-0010 remained
fully functional at a capacitive continuous current load of 4 A after
200.000 switching cycles (for details see documentation).
The signal state of the EtherCAT Terminal is indicated by light
emitting diodes.The EL2595 EtherCAT Terminal contains a
constant current source for LEDs and is designed to control one
or more LEDs connected in series.
The user specifies the required set current, the integrated power supply unit
then provides the required forward voltage, depending on the connected LEDs.
For this purpose, the EL2595 has a step-up/step-down power supply unit,
which generates the output voltage from the 24 V DC input voltage.
The output voltage is also adjusted during operation in order to maintain the
set current. The current can be switched quickly for short-term lighting,
hence even extremely short flashes of light are possible. The pulse duration
is adjustable from 1 µs to infinity, the flash time itself can be set through a
timestamp via distributed clocks; an external trigger input is also available.
Extensive real-time diagnostics, e.g. for input current/voltage and output
current/voltage allow detailed monitoring of the LED light intensity.
If a specifiable load corridor is exited, e.g., due to load errors, the EL2595
switches off to protect the load (resettable).
The EL2212 digital output terminal connects the binary control signals
from the automation device on to the actuators at the process level
with electrical isolation. The multi-timestamp features allow each
EtherCAT cycle to capture as many events per channel as were
preloaded in the internal buffer.
| Basler Electric BE1-32R Power Solid State Relay F1F E1K A4N1F |
| Basler Electric BE1-27/59 UNDERVOLTAGE T238468 |
| Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F |
| Basler Electric BE1-50/51B-235 / BE15051B235 Self-Powered Time Overcurrent Relay |
| Basler Electric PLA2400-12GM / PLA240012GM |
| Basler Electric DECS 125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM |
| Basler Electric BE1-851 Overcurrent Relay H5A2S1N |
| Basler Electric BE1-59N A6EE1JC0N1F Ground Fault Overvoltage Relay |
| Basler Electric BE3-25-1S1N4 / BE3251S1N4 Synchronizing Check Relays |
| Basler Electric L304KC / L304KC Camera Interface |
| Basler Electric SCA1300-32FC / SCA130032FC |
| Basler Electric BE1-27 A3EE1JA1N6F Voltage Relay |
| Basler Electric BE1-51 G1EZ1PA1N0FY Time Overcurrent Relay |
| Basler Electric 9073800-103 Power Supply 110/120v-ac 12.8a Amp 15v-dc |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved