Power Engineering 
K-JIANG
NameDescriptionContent
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51M, Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-50/51B, Self-Powered Time Overcurrent Relay
  • Basler Electric BE1-11m, Motor Protection System
  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0124 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521-0025 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A, ground switching
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
Current Location:

E-mail

Password

Register Forgot password?
DS3800HIOA | General Electric Input Isolator Card Mark IV
❤ Add to collection

DS3800HIOA | General Electric Input Isolator Card Mark IV

+86-18144100983
kongjiangauto@163.com
wind, petroleum, chemical, natural gas, Marine, mining, aviation, electronics, steel, nuclear power, electric power, coking, air separation and so on
PLC, DCS, servo, analog, Ethernet, digital, redundant module, tension system, excitation, generator management, human-machine interface, detection card, sensor, AC drive, etc
DS3800HIOA | General Electric Input Isolator Card Mark IV
U.S.$96150.00
U.S.$4255.00
Weight:2.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Product parameters
  • Tell:+86-18144100983
  • email:kongjiangauto@163.com
  • Application:wind/ petroleum/ chemical/ natural gas/ Marine/ mining/ aviation/ electronics/ steel/ nuclear power/ electric power/ coking/ air separation and so on
  • Series:PLC/ DCS/ servo/ analog/ Ethernet/ digital/ redundant module/ tension system/ excitation/ generator management/ human-machine interface/ detection card/ sensor/ AC drive/ etc
Feature
DS3800HIOA | General Electric Input Isolator Card Mark IV

Product Description P/N: DS3800HIOA DESCRIPTION / SPECIFICATIONS Description The DS3800HIOA is an Input Isolator Card designed for the Mark IV control system. It provides electrical isolation for input signals, ensuring accurate and interference-free data transmission within the system. Technical Specifications Part Number DS3800HIOA Manufacturer General Electric Series Mark IV Product Type High Voltage Input Isolator Board Number of Channels 12 Operating Temperature -30 to 55 degrees Celsius Size 8.25 cm high x 4.18 cm wide Category PLCs/Machine Control Subcategory PC Board PLC/Add-On Board Weight 3.00 lbs Information About DS3800HIOA The DS3800HIOA is a High Voltage Input Isolator Board engineered by General Electric, designed specifically for use in the Mark IV series control systems. This component plays a critical role in ensuring the reliability and accuracy of input signals in industrial environments where high voltage levels and electrical noise are common challenges. As a key part of PLCs (Programmable Logic Controllers) and machine control systems, the DS3800HIOA is categorized as a PC Board PLC/Add-On Board, enhancing the functionality and safety of the control system in which it is integrated. Measuring 8.25 cm in height and 4.18 cm in width, the DS3800HIOA is a compact yet robust component. Despite its small size, the board is engineered to handle the demanding requirements of industrial control systems.

Weighing 3.00 lbs, the board鈥檚 construction reflects the use of high-quality materials and components, ensuring durability and long-term reliability even in harsh operating conditions. The primary function of the DS3800HIOA is to provide electrical isolation for input signals. In an industrial control system, accurate data transmission is essential for maintaining the proper operation of machinery and processes. However, high voltage levels and electrical noise can introduce interference, leading to signal degradation or false readings. The DS3800HIOA mitigates these issues by isolating the input signals from potential sources of interference, thereby ensuring that the data transmitted to the control system is accurate and reliable. This isolation is critical in applications where precision is paramount, such as in the monitoring and control of sensitive processes or equipment. The board is equipped with 12 input channels, allowing it to manage multiple input signals simultaneously. Each channel is designed to handle high voltage inputs while maintaining electrical isolation, ensuring that the integrity of each signal is preserved. The ability to manage multiple channels makes the DS3800HIOA a versatile component, capable of supporting a wide range of applications within the control system. Whether used for monitoring voltage levels, detecting signal changes, or interfacing with other high-voltage equipment, this board provides the necessary isolation and protection to ensure the control system operates smoothly and safely. Operating within a temperature range of -30 to 55 degrees Celsius, the DS3800HIOA is built to perform reliably in diverse environmental conditions. This wide operating temperature range ensures that the board can be deployed in various industrial settings, from temperature-controlled environments to those subject to significant temperature fluctuations. The board鈥檚 design takes into account the need for stability and reliability across this temperature range, with components selected to withstand the stresses associated with continuous operation in challenging conditions. In terms of integration, the DS3800HIOA is designed to be easily incorporated into existing Mark IV control systems. Its standardized size and connector layout ensure that it can be installed without requiring significant modifications to the system. This ease of integration is important for minimizing downtime during installation or replacement, allowing the control system to resume full operation quickly. The board鈥檚 compatibility with other components in the Mark IV series further enhances its utility, making it a valuable addition to any industrial control setup. The DS3800HIOA鈥檚 role in isolating input signals also contributes to the overall safety of the control system. By preventing high voltage from reaching sensitive components or personnel, the board reduces the risk of electrical faults, equipment damage, or injury. This safety feature is particularly important in environments where high voltage equipment is in use, and where maintaining the safety of both the system and its operators is a top priority. Overall, the DS3800HIOA High Voltage Input Isolator Board is an essential component for ensuring the accuracy, reliability, and safety of input signals in industrial control systems. Its ability to handle high voltage inputs across multiple channels, combined with its robust construction and wide operating temperature range, makes it a dependable choice for a variety of applications. As part of the Mark IV series by General Electric, the DS3800HIOA exemplifies the company鈥檚 commitment to quality and innovation in industrial automation. Whether used in new installations or as part of an upgrade to an existing system, the DS3800HIOA provides the performance and protection needed to maintain the efficiency and safety of complex control systems in demanding industrial environments. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • Basler Electric ECM-2 Excitation Control Module
  • Basler Electric BE1-25, Sync-Check Relay
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric BE1-50/51, Self-Powered Time Overcurrent Relays
  • Basler Electric BE1-11, Protection System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric ES Series Protection Relays
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Basler Electric DECS-250, Digital Excitation Control System
  • Beckhoff EL2596-0030 | EtherCAT Terminal, 1-channel LED output
  • Beckhoff EL2596-0010 | EtherCAT Terminal, 1-channel LED output, 0…48 V DC, 3 A
  • Beckhoff EL2596 | EtherCAT Terminal, 1-channel LED output, 0…24 V DC, 3 A
  • Beckhoff EL2595 | EtherCAT Terminal, 1-channel LED output, 2…48 V DC, 0.7 A
  • Beckhoff EL2564-0010 | EtherCAT Terminal, 4-channel LED output, 8…48 V DC, 3 A, RGBW, common cathode
  • Beckhoff EL2564 | EtherCAT Terminal, 4-channel LED output, 5…48 V DC, 4 A, RGBW, common anode
  • Beckhoff EL2535-0103 | EtherCAT Terminal, 2-channel PWM output, 24…48 V DC, 3.5 A, current-controlled
  • Beckhoff EL2535-0005 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 5 A, current-controlled
  • Beckhoff EL2535-0002 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 2 A, current-controlled
  • Beckhoff EL2522 | EtherCAT Terminal, 2-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Alfa Laval How does the Rotacheck work
  • Alfa Laval Rotacheck Sensor Cleaning validation
  • Alfa Laval Indication units Sensing and control
  • Alfa Laval ThinkTop® DeviceNet Sensing and control
  • Alfa Laval ThinkTop Basic® Intrinsically Safe
  • Alfa Laval ThinkTop® V55 Sensing and control
  • Alfa Laval ThinkTop® V70 Sensing and control
  • Omron CK3E Programmable Multi-Axis Motion Controller
  • Omron CK3M Programmable Multi-Axis Motion Controller
  • Alfa Laval ThinkTop® V50 Sensing and control
  • Alfa Laval ThinkTop® V40 Sensing and control
  • Alfa Laval ThinkTop® V20 Sensing and control
  • Alfa Laval PureSOx Exhaust Gas Cleaning
  • Alfa Laval Decanters
  • Alfa Laval Aalborg XWi Natural circulation exhaust gas steam boiler
  • Alfa Laval Aalborg Hukka-8 HRSG Modules
  • Alfa Laval Aalborg H/HW Boiler
  • Alfa Laval Aalborg AV-6N How it works
  • Alfa Laval Aalborg AV-6N Natural circulation exhaust gas waste heat recovery boiler
  • KEBA BL250/B Bus link module
  • LENZE Controllers, system components and engineering tools
  • Kongsberg K-NAV Navigation products
  • Kongsberg AZIMUTH THRUSTERS US azimuth thruster family
  • Kongsberg DECK MACHINERY Safer deck operation
  • Kongsberg K-BRIDGE MFD 26”MULTI-FUNCTIONAL OPERATOR STATION
  • Kongsberg EM 2040P shallow water multibeam echo sounder
  • Kongsberg SENTRY GB-300 WIRELESS TEMPERATURE MONITORING
  • Kongsberg X-band radar scanners
  • Kongsberg MGC® R4 COMPASS System
  • Kongsberg K-Bridge Standalone radar navigation system
  • Kongsberg Density Profile Measurement System
  • Kongsberg CPX propeller lines
  • Kongsberg MGC® R5 COMPASS system
  • Kongsberg MGC® R3 COMPASS System
  • Kongsberg K-Gauge Sensor Reliability application
  • Kongsberg MGC R2 COMPASS system
  • Kongsberg GLA-310/5 DUAL Radar Tank Gauge
  • Kongsberg DZ-110/U Transmitter Barrier Unit
  • Kongsberg K-GAUGE GAS LNG / LPG / NH3 FUEL TANK MONITORING SYSTEM
  • Kongsberg GL-10 Level Switch Water Ingress Detection Sensor
  • Alfa Laval Aalborg electric steam boiler(ESB)
  • Alfa Laval Aalborg XW-TG Waste heat recovery economizer after diesel engine
  • Alfa Laval Aalborg XW Exhaust gas economizer
  • Alfa Laval Aalborg XS-2V Robust Smoke-tube Economizer
  • Alfa Laval Aalborg XS-TC7A Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg XS-7V robust smoke-tube economizer
  • Alfa Laval Aalborg XS-2V and XS-7V
  • Alfa Laval Aalborg Micro Waste heat recovery economizer for marine auxiliary engines
  • Alfa Laval Aalborg AV-14 Waste Heat Recovery Unit after gas turbines
  • Alfa Laval Exhaust gas economizers
  • Alfa Laval Aalborg OC-TCi Self-cleaning composite boiler with multi-fuel and hybrid options
  • Alfa Laval Oil/gas-fired composite steam boilers
  • Alfa Laval Aalborg OS-TCi Self-cleaning fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg OM-TCi
  • Alfa Laval Breaking new ground with the first methanol boiler installationv
  • Alfa Laval Aalborg OL Large-capacity fired boiler with multi-fuel and hybrid options
  • Alfa Laval Aalborg Mini 3-Passv
  • Alfa Laval Aalborg HPNC Boiler
  • Alfa Laval Экономайзер VHE Предназначен для дезодорации и физической рафинации жиров и масел
  • Alfa Laval Aalborg D Multi-fuel
  • Alfa Laval Aalborg D High performance modular boiler plant
  • Alfa Laval Aalborg CHB How it works
  • Alfa Laval Aalborg CHB Oil and gas fired marine steam and hot water boiler
  • Alfa Laval Aalborg 3-Pass oil/gas-fired steam boilers
  • Alfa Laval oil/gas-fired steam boilers
  • LENZE I/O system 3000
  • LENZE v430/v450 web panel
  • LENZE c300 controller
  • LENZE p500 controller
  • LENZE p300 controller
  • LENZE v200-P monitor
  • LENZE v200-C monitor
  • LENZE v800-P industrial PC
  • LENZE v800-C industrial PC
  • LENZE EtherCAT-CAN gateway x750
  • LENZE V450 Web Panel
  • LENZE v430 web panel
  • Beckhoff EL2521-0124 | EtherCAT Terminal, 1-channel pulse train output
  • Beckhoff EL2521-0025 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A, ground switching
  • Beckhoff EL2521-0024 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, 24 V DC, 1 A
  • Beckhoff EL2521 | EtherCAT Terminal, 1-channel pulse train output, incr. enc. simulation, RS422, 50 mA
  • Beckhoff EL2502-0010 | EtherCAT Terminal, 2-channel PWM output, 24 V DC, 0.5 A, timestamping
  • SAACKE ATONOX THE ULTRA-LOW-NOX BURNER FOR YOUR LARGE-SCALE COMBUSTION
  • SAACKE Pulverized fuels.
  • SAACKE SPECIAL GASES.
  • SAACKE Special liquid fuels
  • SAACKE BIOFUELS. Biogenic fuels
  • SAACKE IGNITION AND SUPPORT BURNERS.
  • SAACKE WATER TUBE BOILERS.
  • SAACKE Thermal processing systems
  • SAACKE MODERN LOW-NOX BURNERS FOR ALMOST ANY FUEL
  • SAACKE GreenDock ZERO EMISSION ENERGY IN PORT.
  • SAACKE WASTE HEAT RECOVERY UNIT.
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • Meggitt P702B/P702BF-1 Power unit/amplifier
  • Meggitt VibroSmart® Distributed Monitoring System (DMS)
  • HIMA DI 24 01 HIMatrix Safety-Related Controller
  • HIMA DIO 24/16 01 HIMatrix Safety-Related Controller
  • HIMA X-CI 24 51 HIMax® Counter Module
  • HIMA X-DI 64 51 HIMax®Digital Input Module
  • HIMA X-DI 32 51 HIMax®Digital Input Module
How to install and debug this product? Matters needing attention
Where can I download the manual and programming software?
Is it in stock or need to be ordered?
Can you provide technical service?
Where can I order this series?
Do you have product selection list and pre-sale service?