Model Type: DP40C3P-1 Electrical DP40C3P-1/B/CE Definite Purpose Contactor
OTHER INFORMAITION
• The operator panel is designed for stationary installation on a planar surface, where the following conditions are fulfilled:
– no high explosive risks
– no strong magnetic fields
– no direct sunlight
– no large, sudden temperature changes
• Install the operator panel according to the accompanying installation instructions.
• Ground the operator panel according to the accompanying installation instructions.
• Only qualified personnel may install the operator panel.
• Separate the high voltage, signal and supply cables.
• Make sure that the voltage and polarity of the power source is correct before connecting the operator panel to the power outlet.
• Peripheral equipment must be appropriate for the application and location.
• In a Zone 2 environment, this equipment shall be installed in an enclosure that provides a degree of protection not less
than IP 54 or greater than IP 65 in accordance with IEC/EN 600079-0. The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.
• In a Zone 22 environment, this equipment shall be installed in an enclosure that provides a degree of
protection not less than IP 64 or greater than IP 65 in accordance with IEC/EN 600079-0.
The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.

GPS signals can be reliably received in the following situations
The antenna is mounted in a position where at least one satellite can be received. Under normal conditions
it can receive four satellites. When the
the antenna is mounted on top of a building so that it can “see” most of the sky.
The GPS receiver calculates the position of the satellites as it receives their signals and
synchronizes with the GPS as it receives information from the satellites.
information from the satellites. Once it has calculated its position
it begins to synchronize the RTU by
generating minute pulses and sending the absolute time
absolute time to the RTU560 CPU via the RTU system bus.
The communication unit (CMU) synchronizes itself to the
MIN1 via the leading edge of the minute pulse.
The CMU reads the time and date via the RTU
The CMU reads the time and date via the RTU system bus.