INPUTS
Number of channels
• 8, single-ended
Nominal signal range (span)
• 1 to 5 V
Full signal range
• 0.19 to 5.64 V
Out of range alarm
• Lower threshold – < 0.19 V
• Upper threshold – > 5.64 V
Accuracy (over temp range)
• ± 0.1% of span
Resolution
• 16 bits
Repeatability
• 0.05% of span
Isolation
• Any channel to Railbus – 100 V ac
• Between channels – None
CONFIGURABLE PARAMETERS
Alarms
• High, high-high, low and low-low
Alarm deadband (hysteresis)
• User defined value
Input filter time constant
• User defined value
Input dead zone
• User defined value
Drive on failsafe
• Disabled / upscale / downscale
Channel status
• Active / Inactive
The Control System
Each downloaded application is a complete distributed application running on the target controller.
Multiple applications, running on separate controllers, can be linked together using the peer-topeer tool,
which identifies tagnames for use across the network.
This data exchange mechanism provides a very efficient way of sharing information between multiple controllers.
• 16 single-ended input channels
• Intrinsically safe field circuits
• Simple apparatus, dry contacts
or IS proximity detectors
• Open and short-circuit
field wiring detection
Project backup and restore
You can create a backup file of your project at any time.
This useful feature enables you to save your application in a known state, and if necessary, restore the project to that state.
You can import and export resources from one project to another, enabling you to re-use prior work.
If the results of importing or exporting resources are unsatisfactory, you can choose to restore the project.
Downloader The Workbench
Downloader is used to download the firmware and control strategy to the controller.
With Redundant Controllers, strategy changes can be downloaded to a backup controller without disrupting control in the primary controller.
When the download is complete, the backup controller will take over control and update the primary controller with the changes.
Control can revert back to the primary controller after these changes are incorporated.
Downloading to a simplex controller can be done on-line and without initializing data, the new strategy starting on the next execution cycle.
GE | 8811-IO-DC | 8811-IO-DC 8-Channel Safety DI/DO, 24VDC, module-powered |
GE | 8118-DO-AC | 8118-DO-AC 8-channel DO, 20-250Vac isolated, unpowered |
GE | 8201-HI-IS | 8201-HI-IS 8-channel Intrinsically Safe Analog Input, 4-20mA with Hart |
GE | 8206-TI-IS | 8206-TI-IS 8-channel Intrinsically Safe RTD input |
GE | 8202-HO-IS | 8202-HO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA with Hart |
GE | 8215-DO-IS | 8215-DO-IS 4-channel Intrinsically Safe Digital Output, solenoid driver IIC gas groups |
GE | 8204-AO-IS | 8204-AO-IS 8-channel Intrinsically Safe Analog Output, 4-20 mA |
GE | 8220-DI-IS | 8220-DI-IS 16-channel Intrinsically Safe Digital Input, switch/promixmity detector |
GE | 8205-TI-IS | 8205-TI-IS 8-channel Intrinsically Safe THC/mV input |
GE | 8601-FT-NI | 8601-FT-NI Field terminal, non-incendive (Div 2) |
GE | 8617-FT-NI | 8617-FT-NI Field Terminal, non-incendive, for 16 ch DI |
GE | 8602-FT-ST | 8602-FT-ST Field terminal, standard |
GE | 8618-FT-MT | 8618-FT-MT 16-pin Mass Termination Assembly (Div 2) |
GE | 8603-FT-FU | 8603-FT-FU Field terminal, non-incendive, fused (Div 2) |
GE | 8619-FT-MT | 8619-FT-MT 44-pin Mass Termination Assembly (Div 2) |
GE | 8604-FT-FU | 8604-FT-FU Field terminal, fused |
GE | 8620-FT-MT | 8620-FT-MT Field terminal assembly |
GE | 8605-FT-TC | 8605-FT-TC Field terminal, thermocouple |
GE | 8621-FT-IS | 8621-FT-IS Intrinsically Safe Field terminal, standard |
GE | 8606-FT-RT | 8606-FT-RT Field terminal, RTD |
GE | 8622-FT-IS | 8622-FT-IS Intrinsically Safe Field terminal, loop-disconnect (not for 8 channel DI) |
GE | 8607-FT-TC | 8607-FT-TC Field terminal, 8-channel with T/C |