In addition to our engineering and site-service activities, Westinghouse Electric Belgium
provides training services to customers in the nuclear industry.
Starting from basic courses describing the Pressurized Water Reactor (PWR),
the training scope extends to the plant operation field and Emergency Operating Procedures (EOP’s).
Another area of expertise is represented by the training courses on core damage mitigation and severe accident management.
The courses contained in the 2014 training catalog are arranged in five categories:
Operation and Accident Related Courses
Maintenance Courses
Engineering Courses
Accident-Based Seminars
AP1000
Particular effort is made to eliminate redundancies and repetition between courses,
thus avoiding loss of time for attendees participating in several courses.
DeltaV Live: New Web Displays
DeltaV Live provides the flexibility to easily and securely integrate process information from many different sources
into a single HMI environment, providing an intuitive and cohesive view into your operations.
New Web Displays allow users to securely view web content as operator graphics, making it even easier to expand operator visibility and
awareness within the DeltaV Live HMI.
Web Displays behave as any other dedicated operator graphic.
They can be included in display sets,participate in hierarchical display navigation, and have a dedicated display frame in a layout.
An intuitive toolbar is also included for easy navigation and zooming.
Introduction
Typical applications of this product
Rosemount 3410 Series Ultrasonic Gas Flow Meters have various configurations that
meet a broad range of customer requirements. Each meter comes fully assembled from
Emerson. The technology can be applied to custody transfer, allocation measurement, and check metering applications such as:
• Custody transfer
• Power plants
• Large industrial users
• Production
• Underground storage sites
• Offshore
• Allocation measurement
Features and benefits of the 3411, 3412, and 3414 meter
• Secondary backup measurement
• Configurable read-only serial ports
• GERG-2008 and Detail AGA Methods
• Custody meter verification
• Proven long term stability
• Field proven reliability
• No line obstruction
• No pressure loss
• Low maintenance
• Bi-directional measurement
• Extensive self-diagnostics
• Immediate alarm reporting
• Continuous flow analysis
— Abnormal profile
— Blockage
— Internal bore buildup
— Liquids present in the gas meter
— Reverse flow
— Speed of sound comparison error
• Auto-detected ASCII/RTU Modbus® communications protocol
• Low power consumption
• Sophisticated noise reduction
• Internet-ready communications
• Ethernet access
• On-board LED status indicators
• Analog pressure and temperature inputs
• Communication via Emerson’s AMS™ Device Manager and Field Communicator
• API Chapter 21 compliant event and data logging (gas meters)
• MeterLink™ (a Windows® - based interface software)
• Local display (optional)
• Smart meter verification (4-Path and 8-Path meters)
PK Controller: Now Supporting Native PROFINET
PROFINET is an open industrial Ethernet solution and is based on international standards.
It is a communication protocol designed to exchange data between controllers and devices in an industrial automation network.
And now, both the innovative PK Controller and new PK Flex Controller support native PROFINET,
helping customers enhance their performance and meet the requirements of most of their time-critical applications.
You do not need special hardware or configuration to use PROFINET;
the PK Flex Controller and PK Controller are equipped with PROFINET capability.
PK Flex Controller is a PROFINET controller and will connect with up to 250 devices such as PLCs, Drives,Remote I/O, transmitters and valves.
PROFINET in the PK Flex Controller is compliant with version 2.3 and CC-A functionality.
The Ovation I/O modules are locked into base units. These base units are housed in
the Controller cabinets where they are mounted on DIN rails and wired to the
appropriate field devices.
The standard modular components typically consist of the following:
• Electronics module
• Personality module
• Base Unit (containing the field terminations)
The relay output modular components consist of the following:
• Electronics module
• Base Unit (containing the field terminations)
Recommended Products P/N:
Digital Input (24 or 48 VAC/VDC differential) 1C31232G02
Digital Input (24 or 48 VDC single ended) 1C31232G01
Digital Output (5-60 VDC) Single ended1C31122G01 1C31125G01
Digital Output (relay pnl comm, Local PS) 1C31122G01 1C31125G02
Digital Output (relay pnl comm Remote PS) 1C31122G01 1C31125G03
HART Analog Input Bit (4 - 20 mA) 5X00058G01 5X00059G01
HART Analog Output14 Bit (4 - 20 mA) 5X00062G01 5X00063G01
HART High Performance Analog Input (4 - 20mA) 5X00106G01 5X00109G01
Link Controller RS232 - 1C3116G01 1C31169G01
Link Controller RS485/422 Four Wire 1C3116G01 1C31169G02
Loop Interface (AI: 0-10V AO: 0-10V) 1C31174G01 1C31177G01
Loop Interface (AI: 0-10V AO: 0-10V) 1C31174G21 1C31177G01
Loop Interface (AI: 0-5V AO: 0-10V) 1C31174G02 1C31177G01
Loop Interface (AI: 0 - 5V AO: 0 - 10V) 1C31174G22 1C31177G01
Loop Interface (AI: 4 - 20mA AO: 4 - 20mA Remote PS) 1C31174G03 1C31177G03
Loop Interface (AI: 4 - 20mA AO: 4 - 20mA Remote PS) 1C31174G23 1C31177G03
Loop Interface (AI: 4 - 20mA AO: 4 - 20mA Local PS) 1C31174G03 1C31177G02
Loop Interface (AI: 4 - 20mA AO: 4 - 20mA Local PS) 1C31174G23 1C31177G02
Loop Interface (AI: 4 - 20mA Remote PS) 1C31174G04 1C31177G03
Loop Interface (AI: 4 - 20mA Remote PS) 1C31174G24 1C31177G03
Loop Interface (AI: 4 - 20mA Local PS) 1C31174G04 1C31177G02
Loop Interface (AI: 4 - 20mA Local PS) 1C31174G24 1C31177G02
Pulse Accumulator (24/48V or 5/12V med speed Remote PS, pos/neg com) 1C31147G01 1C31150G03
Pulse Accumulator (24/48V or 5/12V med speed Local PS, neg com) 1C31147G01 1C31150G01
Pulse Accumulator (24/48V or 5/12V med speed Local PS, pos com) 1C31147G01 1C31150G02
Pulse Accumulator (5V high speed Remote PS) 1C31147G02 1C31150G03
Pulse Accumulator (5V high speed, Local PS neg com) 1C31147G02 1C31150G01
Pulse Accumulator (5V high speed, Local PS pos com) 1C31147G02 1C31150G02
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved